STATION = 9.35N 82.25W PBO 2408210600 787935 **************************************************** PBO 2408210600 FORECAST PROJECTION= 0 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.8 7.7 3.1 11. 104. 28. 0. 43 -75.8 9.0 4.8 225. 112. 23. 1. 42 -73.2 10.5 8.3 225. 120. 19. 1. 41 -70.3 12.4 10.2 240. 129. 15. 1. 40 -67.3 14.7 11.7 254. 139. 11. 0. 39 -64.2 16.4 10.3 273. 150. 9. 0. 38 -61.3 16.3 4.9 313. 161. 10. 0. 37 -58.7 13.1 7.1 77. 173. 17. 1. 36 -56.4 8.6 6.9 78. 186. 33. 1. 35 -54.3 6.3 1.7 57. 199. 46. 1. 34 -51.1 6.6 1.4 271. 213. 45. 1. 33 -47.3 7.3 3.2 270. 228. 43. 2. 32 -43.4 7.3 7.4 234. 244. 44. 2. 31 -39.5 7.5 12.8 223. 261. 45. 2. 30 -35.6 8.4 14.5 223. 278. 42. 2. 29 -31.7 12.3 14.1 233. 297. 29. 2. 28 -27.7 18.6 13.0 250. 316. 15. 2. 27 -23.7 20.3 11.8 270. 337. 14. 2. 26 -20.8 9.4 3.4 321. 358. 43. 2. 25 -17.7 7.3 7.0 69. 380. 53. 2. 24 -14.3 9.3 7.8 89. 404. 45. 1. 23 -11.2 10.0 9.7 107. 428. 43. -0. 22 -8.4 11.0 13.1 102. 454. 41. -0. 21 -5.5 12.7 15.6 95. 481. 36. 0. 20 -2.9 12.3 16.1 91. 510. 38. 1. 19 -0.5 10.5 16.5 92. 539. 45. 2. 18 2.0 9.3 15.4 95. 570. 50. 3. 17 4.1 5.9 16.3 96. 603. 65. 3. 16 6.7 5.8 18.3 95. 637. 67. 3. 15 8.6 2.8 18.8 93. 673. 83. 3. 14 11.4 3.4 17.1 97. 710. 80. 3. 13 13.2 1.8 13.3 93. 749. 89. 2. 12 15.2 3.5 9.3 78. 790. 79. 1. 11 16.3 2.8 8.4 68. 822. 83. -0. 10 17.5 1.5 8.3 70. 844. 91. -1. 9 18.3 0.5 8.7 73. 866. 97. -1. 8 19.6 0.6 8.3 68. 889. 97. -1. 7 21.0 0.4 7.7 62. 913. 98. -1. 6 22.9 1.2 5.2 63. 938. 93. -1. 5 24.4 2.1 2.1 19. 959. 88. 0. 4 25.0 2.3 5.4 291. 975. 87. 1. 3 25.6 2.8 9.9 284. 989. 84. 1. 2 26.1 4.2 12.2 279. 999. 78. 0. 1 25.8 3.1 8.0 266. 1005. 83. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408210700 787935 **************************************************** PBO 2408210700 FORECAST PROJECTION= 1 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.2 8.3 13.5 12. 104. 26. -3. 43 -75.5 9.3 4.6 319. 112. 22. -3. 42 -73.4 10.4 7.3 259. 120. 19. -3. 41 -70.7 12.4 11.8 257. 129. 15. -3. 40 -67.5 15.4 13.0 266. 139. 10. -2. 39 -64.3 17.4 10.2 283. 150. 8. -1. 38 -61.3 16.6 5.8 328. 161. 9. 1. 37 -58.5 13.5 6.2 39. 173. 16. 3. 36 -56.2 9.9 6.6 49. 186. 28. 5. 35 -53.9 7.7 4.3 17. 199. 38. 7. 34 -51.0 7.4 4.4 328. 214. 41. 9. 33 -47.3 7.5 5.1 297. 229. 42. 10. 32 -43.5 6.8 7.1 255. 244. 47. 12. 31 -39.6 6.3 11.6 236. 261. 51. 14. 30 -35.6 7.8 14.2 236. 279. 45. 16. 29 -31.6 12.3 14.5 246. 297. 29. 19. 28 -27.6 18.3 13.9 260. 316. 16. 23. 27 -23.8 17.9 11.8 277. 337. 18. 27. 26 -20.5 12.0 6.2 307. 358. 33. 32. 25 -17.6 8.6 5.1 40. 380. 47. 36. 24 -14.6 8.5 7.8 71. 404. 48. 37. 23 -11.8 9.6 10.2 84. 429. 45. 35. 22 -8.9 10.8 13.5 86. 454. 41. 33. 21 -6.1 11.3 15.6 84. 481. 40. 31. 20 -3.4 10.3 16.4 84. 510. 45. 28. 19 -0.9 8.5 16.6 87. 540. 53. 24. 18 1.4 6.4 16.2 90. 571. 63. 20. 17 3.7 4.1 16.4 91. 603. 75. 15. 16 6.0 2.5 16.9 93. 637. 84. 10. 15 8.1 1.2 15.9 99. 673. 92. 7. 14 10.4 0.9 14.2 106. 710. 94. 3. 13 12.5 1.1 11.7 104. 750. 93. 0. 12 14.9 2.4 8.5 95. 790. 86. -2. 11 15.7 1.1 6.4 97. 822. 93. -2. 10 16.7 0.1 6.8 103. 845. 99. -0. 9 18.1 0.1 6.8 104. 867. 99. 1. 8 19.4 0.1 6.0 92. 889. 99. -0. 7 20.9 0.1 6.0 78. 914. 99. -2. 6 22.8 0.8 4.4 83. 939. 95. -2. 5 24.3 1.8 0.9 161. 959. 90. -1. 4 25.1 2.5 5.5 252. 976. 86. 1. 3 25.8 3.6 8.9 263. 989. 81. 1. 2 26.3 4.5 9.7 263. 1000. 76. 0. 1 26.1 2.9 6.2 250. 1006. 84. -0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408210800 787935 **************************************************** PBO 2408210800 FORECAST PROJECTION= 2 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.6 4.7 12.9 11. 104. 46. 1. 43 -75.9 4.7 7.0 348. 112. 48. 2. 42 -73.4 11.2 4.4 299. 120. 17. 2. 41 -70.7 12.9 5.7 286. 129. 14. 2. 40 -67.6 15.9 5.0 300. 139. 9. 1. 39 -64.4 16.9 4.5 358. 149. 8. 1. 38 -61.2 16.6 7.6 41. 161. 9. 0. 37 -58.0 15.5 9.6 61. 173. 12. -0. 36 -55.1 14.3 9.5 80. 186. 15. -1. 35 -52.3 13.3 7.8 97. 199. 19. -1. 34 -49.5 12.5 4.8 118. 213. 22. -0. 33 -46.5 11.4 3.4 177. 228. 26. 2. 32 -43.1 10.1 6.3 211. 244. 32. 4. 31 -39.4 9.2 10.8 216. 261. 37. 8. 30 -35.4 9.9 15.2 219. 278. 36. 11. 29 -31.4 12.6 17.6 223. 297. 28. 15. 28 -27.3 17.1 17.3 230. 316. 18. 19. 27 -23.4 19.5 14.6 236. 336. 15. 23. 26 -19.9 16.4 9.6 238. 358. 22. 28. 25 -16.9 12.2 3.5 203. 380. 34. 32. 24 -14.3 10.1 5.6 121. 404. 42. 35. 23 -11.7 10.2 9.3 111. 428. 42. 36. 22 -9.0 10.9 11.7 105. 454. 41. 36. 21 -6.3 10.1 13.4 96. 481. 44. 34. 20 -3.8 7.8 14.4 90. 509. 55. 32. 19 -1.4 5.2 15.0 85. 539. 68. 27. 18 0.8 3.1 15.7 79. 570. 80. 20. 17 3.0 1.4 17.0 75. 603. 90. 12. 16 5.3 0.5 17.6 72. 637. 97. 4. 15 7.8 0.5 16.4 73. 673. 97. -2. 14 10.4 0.8 13.5 75. 710. 95. -5. 13 12.8 1.4 10.5 73. 749. 91. -5. 12 15.4 2.5 8.5 60. 790. 85. -5. 11 17.0 2.9 7.4 45. 822. 83. -4. 10 18.0 2.7 6.8 39. 844. 84. -1. 9 19.1 2.5 5.7 37. 866. 85. 2. 8 20.3 2.4 4.8 35. 888. 86. 4. 7 21.6 2.1 5.2 22. 913. 88. 6. 6 23.1 2.1 6.6 12. 938. 88. 8. 5 24.4 2.3 6.5 357. 958. 87. 8. 4 25.5 3.0 6.5 329. 975. 84. 8. 3 26.4 4.1 9.2 313. 988. 78. 7. 2 26.6 5.0 11.1 312. 999. 74. 5. 1 25.6 2.8 7.0 332. 1005. 85. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408210900 787935 **************************************************** PBO 2408210900 FORECAST PROJECTION= 3 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -79.6 4.6 27.6 246. 104. 47. 1. 43 -78.9 5.7 25.0 246. 112. 39. 3. 42 -76.0 5.3 18.7 247. 120. 43. 5. 41 -72.9 4.7 8.2 263. 129. 49. 5. 40 -69.8 4.7 6.3 353. 139. 50. 2. 39 -66.9 4.7 8.4 48. 149. 51. -0. 38 -63.2 4.6 14.9 78. 161. 53. -0. 37 -59.3 4.6 23.2 85. 173. 55. 3. 36 -55.3 4.4 23.9 86. 186. 57. 7. 35 -52.0 4.3 15.2 83. 199. 59. 7. 34 -49.1 11.0 7.5 85. 213. 27. 3. 33 -46.2 10.9 0.8 50. 228. 28. -1. 32 -43.0 9.9 4.4 277. 244. 33. -4. 31 -39.4 9.5 7.9 268. 261. 36. -6. 30 -35.5 11.1 11.3 262. 278. 31. -7. 29 -31.5 14.2 13.5 265. 297. 23. -7. 28 -27.7 15.4 12.9 274. 316. 22. -5. 27 -24.2 12.8 9.4 292. 336. 30. -2. 26 -21.2 9.6 5.8 330. 358. 42. 2. 25 -18.3 8.1 5.2 30. 380. 49. 7. 24 -15.4 8.2 8.1 67. 404. 49. 13. 23 -12.5 8.7 10.5 81. 428. 48. 16. 22 -9.8 8.2 11.2 87. 454. 51. 14. 21 -7.1 6.4 11.2 90. 481. 60. 7. 20 -4.6 4.3 12.0 91. 509. 72. -4. 19 -1.9 3.0 13.5 91. 539. 80. -13. 18 0.7 2.4 14.3 92. 570. 84. -16. 17 3.0 1.4 13.3 94. 603. 91. -14. 16 5.0 0.0 11.7 95. 637. 100. -12. 15 7.8 0.0 11.0 98. 673. 100. -15. 14 10.1 0.0 10.0 93. 710. 100. -18. 13 12.2 0.0 9.1 78. 749. 100. -20. 12 14.4 0.0 8.6 70. 790. 100. -23. 11 16.1 0.1 7.9 57. 822. 100. -27. 10 17.1 0.1 7.6 52. 844. 100. -27. 9 18.3 0.4 7.6 50. 867. 98. -26. 8 20.0 1.5 7.4 49. 889. 91. -23. 7 21.7 2.5 7.0 46. 913. 86. -18. 6 23.4 3.0 6.4 40. 938. 83. -12. 5 24.7 3.0 5.6 32. 959. 83. -7. 4 25.7 3.1 4.2 4. 975. 83. -2. 3 26.5 4.0 5.3 314. 989. 79. 1. 2 26.8 5.0 9.2 308. 999. 74. 2. 1 25.9 3.3 6.2 330. 1005. 82. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408211000 787935 **************************************************** PBO 2408211000 FORECAST PROJECTION= 4 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -79.0 4.9 4.7 58. 104. 45. 2. 43 -76.6 7.8 2.9 8. 112. 28. 7. 42 -74.1 10.9 4.3 312. 120. 17. 11. 41 -71.5 12.9 6.6 305. 129. 13. 13. 40 -68.5 13.8 8.9 319. 139. 12. 12. 39 -65.3 13.6 14.1 331. 149. 14. 10. 38 -62.4 9.7 15.0 337. 161. 26. 7. 37 -59.3 7.5 8.0 354. 173. 37. 6. 36 -56.7 7.3 13.5 50. 186. 39. 9. 35 -53.6 6.8 19.7 58. 199. 43. 14. 34 -49.5 5.2 17.2 51. 213. 54. 17. 33 -45.1 8.3 16.6 50. 228. 39. 18. 32 -41.1 11.4 7.8 12. 244. 28. 18. 31 -38.2 13.0 4.0 278. 261. 24. 17. 30 -34.8 14.0 7.1 226. 278. 23. 14. 29 -31.0 16.1 10.4 217. 297. 19. 11. 28 -27.1 18.6 12.4 221. 316. 15. 6. 27 -23.4 18.2 10.7 224. 336. 17. 0. 26 -20.2 15.2 5.3 207. 357. 25. -8. 25 -17.0 10.0 5.6 134. 380. 41. -16. 24 -14.0 3.9 10.5 127. 403. 72. -22. 23 -11.3 1.3 12.6 135. 428. 90. -22. 22 -8.8 4.4 8.6 124. 454. 71. -20. 21 -6.5 6.9 7.7 115. 481. 58. -19. 20 -4.8 3.2 9.1 110. 509. 78. -19. 19 -2.7 0.0 10.8 103. 539. 100. -23. 18 0.3 0.0 11.8 90. 570. 100. -35. 17 2.8 0.0 13.3 79. 603. 100. -51. 16 5.2 0.0 14.6 77. 637. 100. -60. 15 7.6 0.0 14.9 79. 672. 100. -55. 14 10.4 0.7 13.4 83. 710. 95. -32. 13 12.9 0.9 9.7 80. 749. 94. 5. 12 14.8 0.2 7.9 53. 790. 99. 44. 11 16.6 0.5 8.1 34. 822. 97. 73. 10 17.7 0.6 8.4 19. 844. 96. 91. 9 19.0 1.1 8.6 7. 866. 93. 107. 8 20.3 1.7 8.7 356. 888. 90. 116. 7 21.6 2.1 8.6 348. 913. 88. 114. 6 22.9 2.5 8.1 345. 938. 86. 97. 5 24.1 2.6 7.1 339. 958. 85. 73. 4 24.9 2.7 6.5 323. 975. 85. 49. 3 25.4 2.6 7.1 301. 988. 85. 28. 2 25.3 2.5 8.9 285. 999. 86. 14. 1 25.1 1.5 7.4 286. 1004. 91. 4. PRCP(HR)=.016 PRCP(TOT)= 0.016 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408211100 787935 **************************************************** PBO 2408211100 FORECAST PROJECTION= 5 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -81.8 4.6 17.8 243. 104. 46. 1. 43 -81.2 4.8 17.2 248. 112. 45. 1. 42 -78.4 4.6 12.4 257. 120. 47. -1. 41 -75.2 4.7 9.8 295. 129. 48. -4. 40 -71.7 4.7 10.8 335. 139. 49. -8. 39 -68.0 4.7 12.8 357. 150. 51. -8. 38 -63.7 4.6 12.7 5. 161. 53. -6. 37 -59.6 4.6 9.0 359. 173. 55. -2. 36 -55.8 4.5 4.0 1. 186. 57. 3. 35 -52.2 6.9 3.1 94. 199. 43. 6. 34 -48.6 8.1 6.4 105. 214. 38. 4. 33 -45.1 8.3 7.1 104. 229. 39. 1. 32 -41.4 10.9 3.5 187. 244. 30. -1. 31 -37.7 14.6 9.4 237. 261. 20. -1. 30 -34.1 17.1 11.1 245. 279. 16. -2. 29 -30.4 18.8 11.3 256. 297. 14. -4. 28 -26.7 20.2 13.1 270. 316. 13. -7. 27 -23.2 18.9 14.0 286. 337. 16. -11. 26 -20.0 14.4 10.8 302. 358. 27. -13. 25 -17.1 6.6 3.0 346. 380. 57. -10. 24 -14.4 1.6 7.9 76. 404. 88. -2. 23 -12.7 1.7 23.9 83. 429. 87. 5. 22 -10.4 2.6 27.0 85. 455. 81. 4. 21 -7.4 4.2 24.5 84. 482. 72. -5. 20 -3.9 6.4 21.3 81. 510. 61. -11. 19 -0.4 8.8 17.6 76. 540. 51. -9. 18 2.6 10.5 14.4 73. 571. 46. -4. 17 4.3 7.7 11.7 70. 603. 57. 0. 16 5.5 2.7 10.5 66. 638. 83. 7. 15 7.0 1.1 12.0 72. 673. 93. 19. 14 9.3 2.7 14.5 82. 711. 83. 31. 13 12.1 4.5 15.0 84. 750. 74. 38. 12 14.9 5.7 13.5 72. 790. 69. 35. 11 16.8 5.9 13.5 58. 822. 68. 29. 10 17.9 5.3 14.9 44. 845. 71. 23. 9 19.0 4.4 15.3 32. 867. 76. 18. 8 20.1 3.3 13.0 28. 889. 81. 13. 7 21.2 1.3 8.7 10. 914. 92. 8. 6 22.3 0.7 9.9 350. 938. 96. 3. 5 23.4 1.2 11.8 344. 959. 93. 1. 4 24.4 2.0 11.6 342. 976. 89. -0. 3 25.0 2.4 8.9 344. 989. 87. 0. 2 25.0 1.8 6.2 356. 1000. 89. 1. 1 24.8 1.1 5.2 24. 1005. 94. 1. PRCP(HR)=.022 PRCP(TOT)= 0.022 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408211200 787935 **************************************************** PBO 2408211200 FORECAST PROJECTION= 6 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -80.1 4.7 9.5 78. 104. 46. 5. 43 -77.0 7.8 6.4 38. 112. 28. 16. 42 -74.2 10.6 7.7 336. 120. 18. 23. 41 -71.5 12.9 11.9 303. 129. 13. 25. 40 -68.7 14.2 13.7 284. 139. 11. 22. 39 -65.7 14.4 12.2 265. 150. 12. 15. 38 -62.7 12.3 10.2 243. 161. 17. 7. 37 -59.4 11.0 8.7 229. 173. 23. -1. 36 -55.7 9.6 5.7 231. 186. 29. -11. 35 -51.7 8.0 4.4 218. 199. 38. -22. 34 -48.3 7.7 5.2 200. 214. 40. -31. 33 -45.3 8.2 5.0 206. 229. 39. -36. 32 -41.9 11.5 7.3 226. 244. 27. -36. 31 -38.4 14.2 9.5 232. 261. 21. -32. 30 -34.9 15.4 10.9 244. 279. 19. -25. 29 -31.3 15.4 11.8 261. 297. 21. -14. 28 -27.9 13.9 11.6 275. 316. 25. -2. 27 -24.6 9.2 8.4 292. 337. 42. 7. 26 -21.0 6.1 4.9 289. 358. 58. 14. 25 -17.3 4.0 1.5 61. 381. 71. 18. 24 -15.2 1.6 11.2 74. 404. 87. 21. 23 -12.9 1.3 13.3 64. 429. 90. 22. 22 -9.8 2.8 12.7 66. 455. 80. 21. 21 -6.6 5.5 10.9 66. 482. 65. 17. 20 -4.2 6.7 11.3 64. 510. 60. 13. 19 -2.0 5.7 12.9 77. 540. 65. 12. 18 0.6 5.2 14.8 89. 571. 68. 13. 17 3.4 5.1 16.5 89. 604. 69. 14. 16 5.7 3.7 17.5 82. 638. 77. 13. 15 8.0 2.4 17.8 75. 674. 85. 9. 14 10.0 1.5 17.2 67. 711. 90. 1. 13 12.4 2.2 15.7 64. 750. 87. -8. 12 15.4 4.3 14.0 57. 791. 76. -11. 11 17.2 4.4 12.8 50. 823. 75. -10. 10 17.8 3.0 11.6 47. 845. 83. -10. 9 18.8 2.2 8.0 31. 868. 87. -9. 8 19.8 1.7 6.3 329. 890. 90. -7. 7 20.7 1.0 9.4 317. 914. 94. -9. 6 21.9 0.9 11.5 320. 939. 95. -12. 5 23.4 2.4 11.7 324. 960. 87. -11. 4 24.2 3.4 10.8 330. 976. 81. -7. 3 24.8 5.1 9.8 343. 990. 73. -3. 2 24.6 5.3 9.7 343. 1000. 73. 0. 1 23.8 3.0 5.6 326. 1006. 83. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408211300 787935 **************************************************** PBO 2408211300 FORECAST PROJECTION= 7 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.2 4.9 14.8 30. 104. 45. -1. 43 -75.8 7.5 20.5 318. 112. 30. -4. 42 -73.1 10.4 20.7 311. 120. 19. -5. 41 -71.1 10.0 17.4 304. 129. 22. -1. 40 -69.0 7.9 10.4 299. 139. 31. 5. 39 -66.8 6.5 3.8 249. 150. 39. 11. 38 -64.1 4.7 4.3 201. 161. 53. 11. 37 -60.4 4.6 5.6 216. 173. 55. 10. 36 -56.4 4.5 7.9 218. 186. 57. 9. 35 -52.7 4.4 9.2 212. 199. 59. 9. 34 -49.0 5.6 8.9 207. 214. 52. 10. 33 -45.3 8.9 6.9 204. 229. 36. 12. 32 -41.7 12.6 4.9 200. 245. 24. 14. 31 -38.1 15.7 4.2 213. 261. 18. 14. 30 -34.6 14.0 5.4 250. 279. 23. 14. 29 -31.0 12.5 10.7 273. 297. 28. 12. 28 -27.5 11.1 13.7 281. 317. 34. 9. 27 -23.9 12.9 10.0 294. 337. 30. 6. 26 -20.5 8.8 4.2 327. 358. 45. 3. 25 -17.7 3.6 5.6 54. 381. 74. 1. 24 -15.0 3.3 10.7 58. 404. 76. 0. 23 -12.1 2.5 13.8 76. 429. 82. -0. 22 -9.3 3.2 11.4 97. 455. 78. -1. 21 -6.6 4.9 11.9 105. 482. 68. -1. 20 -4.0 5.7 12.8 98. 510. 65. -1. 19 -1.1 7.0 13.8 91. 540. 59. 2. 18 1.4 7.3 16.4 85. 571. 58. 7. 17 3.9 7.1 18.5 79. 604. 60. 12. 16 6.3 6.0 17.3 76. 638. 65. 15. 15 8.4 4.1 15.3 77. 674. 75. 16. 14 10.0 1.5 13.3 78. 711. 91. 16. 13 12.0 0.0 11.3 75. 750. 100. 13. 12 14.2 0.2 10.1 69. 791. 98. 7. 11 15.9 1.0 10.2 68. 823. 94. 1. 10 17.1 1.3 9.3 69. 845. 92. -1. 9 18.4 1.4 5.2 30. 868. 92. -1. 8 19.7 1.1 8.8 323. 890. 93. 0. 7 20.7 1.5 9.4 313. 915. 91. 1. 6 22.5 4.2 9.2 322. 939. 77. 1. 5 23.3 3.3 10.5 314. 960. 82. 1. 4 23.6 1.1 12.9 305. 977. 94. 1. 3 23.8 1.2 11.8 303. 990. 93. -0. 2 24.1 2.0 8.1 296. 1001. 89. -0. 1 24.5 2.0 6.4 287. 1006. 89. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408211400 787935 **************************************************** PBO 2408211400 FORECAST PROJECTION= 8 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.8 4.6 23.2 19. 104. 47. -3. 43 -76.6 5.5 13.4 346. 112. 42. -9. 42 -74.1 9.2 13.8 300. 120. 23. -15. 41 -72.2 9.4 16.0 282. 129. 23. -20. 40 -70.4 5.8 10.2 284. 139. 42. -25. 39 -67.9 4.7 2.3 342. 150. 51. -27. 38 -64.5 4.7 1.8 73. 161. 53. -28. 37 -60.4 4.6 2.2 216. 173. 55. -27. 36 -56.3 4.5 3.8 243. 186. 57. -22. 35 -52.3 6.7 2.7 297. 199. 44. -17. 34 -48.5 10.8 4.2 1. 214. 27. -13. 33 -44.8 12.3 7.3 22. 229. 24. -8. 32 -41.1 13.3 10.3 30. 244. 22. -3. 31 -37.5 15.6 9.5 32. 261. 18. 4. 30 -34.1 12.7 6.0 9. 279. 27. 10. 29 -30.7 15.4 7.9 308. 297. 21. 13. 28 -27.1 19.0 11.9 292. 316. 15. 13. 27 -23.5 15.5 11.6 296. 337. 23. 11. 26 -20.1 12.5 8.2 311. 358. 32. 6. 25 -16.6 13.2 5.4 329. 381. 31. -2. 24 -13.3 11.1 6.1 31. 404. 39. -9. 23 -10.5 7.8 11.2 87. 429. 53. -14. 22 -8.1 8.9 13.5 110. 455. 49. -16. 21 -5.7 10.5 14.0 114. 482. 43. -18. 20 -3.5 8.4 14.4 111. 510. 52. -18. 19 -1.7 3.9 15.0 107. 540. 75. -15. 18 0.1 0.0 16.0 98. 571. 100. -7. 17 3.0 0.0 15.7 87. 604. 100. 2. 16 5.1 0.0 14.1 72. 638. 100. 10. 15 7.2 0.1 14.2 64. 674. 99. 14. 14 9.7 0.7 14.1 60. 711. 95. 14. 13 12.4 1.1 12.5 59. 750. 93. 11. 12 14.9 1.3 10.1 63. 791. 92. 6. 11 16.8 1.5 8.5 67. 823. 91. 3. 10 17.4 0.7 6.7 78. 846. 96. 2. 9 18.5 1.2 2.7 44. 868. 93. 1. 8 20.0 2.8 6.1 337. 890. 84. -2. 7 21.1 1.9 9.3 356. 915. 89. -6. 6 22.3 1.8 10.0 360. 939. 89. -8. 5 24.0 3.6 10.0 331. 960. 80. -6. 4 24.1 2.1 12.5 310. 977. 88. -3. 3 24.2 1.3 11.9 300. 990. 93. -1. 2 25.0 1.7 9.2 302. 1001. 90. 0. 1 25.5 2.0 8.2 302. 1007. 89. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408211500 787935 **************************************************** PBO 2408211500 FORECAST PROJECTION= 9 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.3 5.3 22.4 86. 104. 43. -0. 43 -74.2 7.4 8.6 34. 112. 31. -1. 42 -73.3 7.2 6.6 260. 120. 33. -2. 41 -73.1 4.8 9.5 232. 129. 48. -4. 40 -72.1 4.7 6.2 187. 139. 49. -9. 39 -69.2 4.7 5.9 174. 150. 50. -15. 38 -65.0 4.7 8.2 196. 161. 52. -21. 37 -60.8 4.6 9.9 197. 173. 54. -24. 36 -56.7 4.5 8.1 191. 186. 57. -24. 35 -52.5 4.4 4.4 166. 200. 59. -20. 34 -48.6 4.2 4.5 85. 214. 61. -11. 33 -44.8 4.0 9.7 51. 229. 64. 2. 32 -41.1 3.9 14.4 36. 245. 66. 18. 31 -37.5 5.7 11.2 21. 261. 55. 32. 30 -34.4 10.2 9.9 334. 279. 35. 40. 29 -31.2 11.6 13.1 318. 297. 31. 39. 28 -27.7 9.9 13.8 330. 317. 38. 31. 27 -24.1 6.2 13.6 351. 337. 57. 17. 26 -20.2 -0.0 6.9 37. 359. 100. -6. 25 -16.4 -0.0 5.3 87. 381. 100. -33. 24 -13.8 -0.0 7.9 74. 405. 100. -54. 23 -11.2 0.0 9.1 71. 430. 100. -57. 22 -8.7 0.0 9.9 81. 456. 100. -44. 21 -6.3 0.0 11.1 94. 483. 100. -17. 20 -4.0 0.0 11.2 101. 511. 100. 15. 19 -1.5 0.3 8.3 102. 541. 98. 46. 18 0.5 0.2 2.9 72. 573. 98. 70. 17 2.7 0.9 7.7 339. 605. 94. 80. 16 6.0 3.0 11.0 346. 640. 81. 73. 15 8.3 3.9 11.2 8. 675. 76. 48. 14 9.9 3.9 9.9 30. 713. 76. 6. 13 11.1 2.5 9.1 9. 752. 85. -42. 12 13.3 1.0 10.9 351. 793. 94. -80. 11 15.4 0.4 10.1 2. 825. 97. -95. 10 17.1 0.6 8.5 8. 847. 96. -89. 9 18.4 0.5 7.5 12. 870. 97. -76. 8 19.4 0.4 7.3 6. 892. 97. -65. 7 20.5 1.0 8.6 342. 916. 94. -56. 6 21.6 2.5 11.0 328. 941. 85. -46. 5 22.7 3.7 11.5 330. 962. 80. -35. 4 23.6 3.4 10.6 325. 979. 81. -23. 3 24.6 3.2 9.8 321. 992. 82. -13. 2 25.2 2.5 8.1 328. 1003. 86. -6. 1 25.3 1.7 5.0 352. 1008. 90. -1. PRCP(HR)=.020 PRCP(TOT)= 0.020 SFC PRES=1011. **************************************************** STATION = 9.35N 82.25W PBO 2408211600 787935 **************************************************** PBO 2408211600 FORECAST PROJECTION=10 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.3 5.2 13.5 97. 104. 44. 4. 43 -74.4 8.1 12.0 35. 112. 28. 5. 42 -71.3 11.8 14.8 15. 120. 16. -0. 41 -69.9 10.9 7.8 297. 129. 19. -6. 40 -69.3 7.2 11.4 255. 139. 34. -7. 39 -67.9 5.7 11.4 218. 150. 44. -4. 38 -65.1 4.9 13.7 189. 161. 50. 1. 37 -61.2 4.6 13.4 188. 173. 54. 6. 36 -57.1 4.5 10.6 201. 186. 56. 8. 35 -53.0 4.4 6.6 212. 199. 59. 9. 34 -49.0 4.9 2.5 188. 214. 57. 11. 33 -45.4 5.5 11.3 45. 229. 54. 12. 32 -41.9 4.0 13.1 36. 245. 65. 8. 31 -38.4 3.7 9.5 358. 261. 68. 2. 30 -35.1 6.4 7.9 311. 279. 52. -1. 29 -31.5 8.7 6.8 305. 297. 42. -4. 28 -27.5 4.5 6.0 311. 317. 65. -13. 27 -23.2 2.4 4.6 303. 337. 81. -20. 26 -19.2 1.6 5.8 234. 358. 87. -16. 25 -16.2 1.2 8.9 202. 381. 91. -6. 24 -13.6 1.3 7.0 156. 404. 90. 0. 23 -11.4 1.6 10.7 87. 429. 88. 2. 22 -9.0 2.4 19.2 76. 455. 82. 9. 21 -6.5 3.0 20.4 86. 482. 79. 16. 20 -4.2 2.4 20.4 88. 511. 83. 20. 19 -1.8 1.7 19.8 85. 540. 88. 22. 18 1.5 2.8 20.4 82. 572. 82. 29. 17 2.3 1.5 21.2 84. 604. 90. 37. 16 5.1 1.5 18.9 87. 639. 90. 38. 15 8.2 2.9 15.9 83. 674. 82. 36. 14 10.8 5.3 13.5 73. 712. 70. 34. 13 13.3 5.0 13.3 59. 751. 72. 31. 12 15.3 2.2 13.2 52. 792. 87. 24. 11 16.9 1.7 10.6 50. 824. 90. 21. 10 18.0 1.9 7.0 42. 846. 88. 24. 9 19.2 2.6 4.5 28. 868. 85. 27. 8 20.5 3.3 3.1 17. 891. 82. 26. 7 21.6 3.5 2.1 20. 915. 80. 20. 6 22.2 3.9 1.7 357. 940. 78. 15. 5 22.9 3.4 5.0 315. 961. 81. 14. 4 23.7 2.7 8.2 300. 977. 85. 13. 3 24.1 2.1 9.5 288. 990. 88. 11. 2 24.5 1.3 7.5 277. 1001. 92. 7. 1 25.1 1.5 6.5 274. 1007. 92. 2. PRCP(HR)=.075 PRCP(TOT)= 0.075 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408211700 787935 **************************************************** PBO 2408211700 FORECAST PROJECTION=11 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.3 5.1 14.2 110. 104. 43. 2. 43 -75.5 6.3 13.9 69. 112. 37. 6. 42 -72.6 9.6 10.9 16. 120. 22. 8. 41 -69.9 12.3 14.9 341. 129. 15. 9. 40 -67.6 12.0 14.8 317. 139. 17. 10. 39 -66.4 8.7 13.6 273. 150. 28. 11. 38 -64.8 6.0 11.7 222. 161. 44. 10. 37 -61.7 4.6 15.0 185. 173. 54. 8. 36 -57.6 4.5 16.0 193. 186. 56. 4. 35 -53.3 4.4 15.1 215. 199. 58. 0. 34 -49.2 4.2 11.3 219. 214. 61. -2. 33 -45.4 4.1 6.2 175. 229. 63. -3. 32 -41.8 3.9 5.5 137. 245. 66. -2. 31 -38.2 3.7 3.4 301. 261. 68. 1. 30 -34.3 9.6 9.6 298. 279. 37. 2. 29 -30.7 15.1 11.4 294. 297. 21. 2. 28 -27.2 15.0 11.6 295. 316. 23. 0. 27 -23.6 11.6 9.4 295. 337. 34. -3. 26 -20.1 2.8 2.4 279. 358. 78. -6. 25 -17.7 1.4 15.3 82. 381. 89. -5. 24 -14.5 2.7 16.3 89. 404. 80. -1. 23 -11.4 3.7 15.0 87. 429. 74. 1. 22 -8.6 4.0 15.1 83. 455. 73. -2. 21 -5.8 4.7 15.1 83. 482. 69. -4. 20 -3.2 5.7 15.3 94. 510. 65. -4. 19 -0.6 6.8 16.3 106. 540. 60. -4. 18 2.2 8.7 16.4 103. 571. 52. -6. 17 4.3 8.0 15.2 95. 604. 56. -10. 16 6.1 4.9 11.9 91. 638. 71. -12. 15 8.5 4.5 8.6 80. 674. 73. -13. 14 10.5 5.3 9.8 62. 711. 70. -15. 13 13.0 5.2 8.9 54. 750. 71. -20. 12 15.0 2.0 6.0 50. 791. 88. -24. 11 16.1 0.0 6.5 60. 823. 100. -26. 10 17.2 0.0 8.3 58. 845. 100. -25. 9 18.1 0.0 9.1 46. 868. 100. -18. 8 19.5 0.8 8.2 18. 890. 95. -6. 7 21.1 2.4 9.8 335. 914. 86. 8. 6 22.5 3.5 9.2 315. 939. 80. 17. 5 23.5 3.8 7.4 300. 960. 79. 19. 4 24.3 3.6 6.5 289. 976. 80. 17. 3 24.9 3.4 5.9 286. 990. 81. 12. 2 25.1 2.2 4.1 272. 1000. 87. 6. 1 25.7 2.3 3.4 262. 1006. 87. 2. PRCP(HR)=.048 PRCP(TOT)= 0.048 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408211800 787935 **************************************************** PBO 2408211800 FORECAST PROJECTION=12 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.9 5.8 17.8 108. 104. 39. -1. 43 -75.1 8.0 12.8 99. 112. 28. -2. 42 -72.7 11.9 10.5 11. 120. 15. -1. 41 -71.0 12.4 12.9 339. 129. 15. -0. 40 -69.2 9.1 13.9 314. 139. 26. 2. 39 -67.2 6.7 10.9 284. 150. 38. 4. 38 -64.8 5.5 10.3 236. 161. 47. 7. 37 -61.8 5.2 14.1 194. 173. 50. 10. 36 -57.9 5.2 16.1 190. 186. 51. 13. 35 -53.6 5.6 14.2 205. 199. 50. 15. 34 -49.5 5.8 10.5 225. 214. 50. 14. 33 -45.4 5.5 4.9 221. 229. 54. 11. 32 -41.6 4.3 3.5 151. 244. 63. 6. 31 -37.8 3.8 4.7 355. 261. 67. -0. 30 -34.0 6.1 8.1 320. 279. 54. -4. 29 -30.2 9.9 11.4 308. 297. 37. -3. 28 -26.7 7.5 12.7 318. 316. 49. -0. 27 -23.4 5.7 7.8 290. 337. 59. 2. 26 -20.1 3.7 1.2 14. 358. 72. 3. 25 -17.2 2.6 7.8 31. 380. 80. 3. 24 -14.3 2.3 8.6 50. 404. 82. 4. 23 -11.5 3.1 10.2 76. 429. 78. 6. 22 -8.7 4.5 11.0 91. 455. 70. 10. 21 -6.0 5.9 11.2 109. 482. 63. 12. 20 -3.8 6.2 12.1 113. 510. 62. 12. 19 -1.5 6.0 13.3 102. 540. 63. 12. 18 0.9 6.8 14.5 86. 571. 61. 12. 17 3.5 7.9 14.8 79. 603. 56. 12. 16 6.1 5.8 14.3 79. 637. 66. 11. 15 8.6 3.6 13.4 76. 673. 78. 11. 14 10.9 4.1 13.1 66. 710. 76. 10. 13 13.0 3.9 9.2 47. 749. 77. 10. 12 14.8 1.9 6.2 38. 790. 89. 12. 11 16.3 1.1 4.7 37. 822. 93. 14. 10 17.5 1.2 4.9 35. 845. 93. 17. 9 18.9 1.9 5.8 26. 867. 88. 19. 8 20.4 2.6 6.6 22. 889. 85. 20. 7 21.9 3.0 6.4 10. 914. 83. 20. 6 23.4 3.3 7.3 352. 938. 82. 17. 5 24.8 4.3 8.7 341. 959. 77. 13. 4 26.0 6.3 9.2 323. 976. 68. 9. 3 26.8 5.9 9.2 307. 989. 70. 6. 2 27.7 5.7 8.5 301. 1000. 71. 3. 1 28.3 5.6 7.4 296. 1005. 71. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408211900 787935 **************************************************** PBO 2408211900 FORECAST PROJECTION=13 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.6 5.4 12.7 99. 104. 41. 2. 43 -76.4 7.2 8.7 97. 112. 31. 7. 42 -73.5 10.1 6.3 62. 120. 20. 9. 41 -70.9 11.4 6.7 5. 129. 17. 10. 40 -68.6 10.9 5.6 299. 139. 19. 10. 39 -66.3 10.2 8.1 253. 150. 23. 8. 38 -63.2 10.4 9.1 249. 161. 23. 4. 37 -60.4 8.8 9.6 218. 173. 31. 1. 36 -57.3 6.6 10.3 216. 186. 43. -1. 35 -53.5 5.7 8.1 226. 199. 50. -1. 34 -49.4 6.1 5.0 225. 213. 49. -3. 33 -45.2 6.4 3.6 194. 228. 48. -8. 32 -41.6 4.0 2.9 148. 244. 65. -11. 31 -38.1 3.7 2.0 6. 261. 68. -11. 30 -34.3 8.6 6.2 305. 278. 42. -9. 29 -30.5 15.2 10.1 299. 297. 21. -5. 28 -26.9 12.8 10.8 299. 316. 29. -2. 27 -23.3 6.8 6.0 301. 337. 54. -0. 26 -20.1 4.0 2.8 333. 358. 70. 2. 25 -17.3 2.8 6.5 353. 380. 79. 5. 24 -14.6 3.1 6.4 41. 404. 77. 10. 23 -11.7 4.3 8.9 75. 428. 71. 15. 22 -8.8 4.3 10.2 98. 454. 71. 16. 21 -6.1 3.8 10.8 105. 481. 75. 12. 20 -3.6 4.2 10.8 95. 510. 73. 7. 19 -1.2 4.9 10.9 81. 540. 69. 1. 18 1.2 4.8 11.8 75. 571. 70. -4. 17 3.7 6.1 11.6 69. 603. 64. -7. 16 6.4 8.6 10.4 61. 637. 54. -8. 15 8.7 7.5 8.8 54. 673. 59. -6. 14 10.6 5.1 7.5 46. 710. 71. -5. 13 12.4 2.8 5.6 30. 749. 83. -4. 12 14.3 1.6 4.9 11. 790. 90. -4. 11 16.0 1.8 5.2 4. 822. 89. -4. 10 17.4 2.1 5.5 6. 844. 88. -4. 9 18.8 2.1 5.9 14. 866. 88. -5. 8 20.1 2.0 6.4 26. 889. 88. -8. 7 21.7 2.4 6.6 34. 913. 86. -10. 6 23.5 3.2 6.3 28. 938. 82. -10. 5 25.0 3.8 6.5 8. 959. 80. -9. 4 26.3 4.5 6.9 1. 975. 76. -8. 3 27.6 5.3 7.0 3. 989. 73. -7. 2 28.6 6.0 6.9 5. 999. 70. -4. 1 29.3 6.4 6.5 6. 1005. 68. -0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408212000 787935 **************************************************** PBO 2408212000 FORECAST PROJECTION=14 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.5 6.9 11.9 109. 104. 32. -0. 43 -75.8 7.7 5.5 136. 112. 29. -1. 42 -73.0 10.6 0.1 169. 120. 19. 1. 41 -70.4 12.0 5.7 348. 129. 16. 2. 40 -67.8 13.2 7.9 331. 139. 14. 3. 39 -65.6 11.7 6.7 310. 149. 18. 1. 38 -63.7 7.6 5.6 257. 161. 35. -1. 37 -61.5 4.6 9.0 209. 173. 54. -2. 36 -58.0 4.5 9.0 219. 186. 56. -2. 35 -54.0 4.4 6.3 255. 199. 58. -2. 34 -49.8 4.3 4.9 225. 213. 61. -3. 33 -45.7 4.1 5.9 185. 228. 63. -3. 32 -41.6 3.9 4.1 160. 244. 66. -1. 31 -38.0 3.7 2.2 249. 261. 68. 3. 30 -34.4 9.0 7.8 276. 278. 40. 5. 29 -30.8 13.4 10.8 287. 297. 26. 6. 28 -27.3 12.9 12.1 296. 316. 28. 7. 27 -23.6 7.7 9.6 294. 336. 49. 7. 26 -20.1 4.0 5.3 293. 358. 70. 6. 25 -17.2 3.7 7.3 344. 380. 73. 3. 24 -14.2 5.4 4.9 26. 404. 64. 2. 23 -11.2 6.5 5.5 70. 428. 59. 3. 22 -8.5 4.4 7.6 93. 454. 71. 3. 21 -6.2 2.1 10.0 92. 481. 85. 2. 20 -4.1 1.4 10.8 94. 509. 90. 0. 19 -1.9 2.4 11.4 92. 539. 84. -2. 18 0.6 4.6 11.7 86. 570. 71. -4. 17 3.4 6.9 10.3 79. 603. 60. -3. 16 6.4 10.3 9.6 70. 637. 48. -1. 15 9.0 9.9 9.8 64. 672. 50. 1. 14 11.3 7.8 9.6 57. 710. 59. 3. 13 13.3 6.1 7.4 39. 749. 66. 4. 12 15.4 4.4 6.3 10. 789. 75. 1. 11 17.2 3.8 5.6 356. 821. 78. -2. 10 18.0 2.9 5.2 342. 843. 83. -4. 9 19.0 2.4 5.1 339. 866. 86. -4. 8 20.3 2.3 5.0 355. 888. 87. -3. 7 21.8 2.7 5.5 18. 912. 85. -0. 6 23.6 3.5 6.1 26. 937. 81. 3. 5 25.0 4.1 7.0 20. 958. 78. 5. 4 25.9 4.3 8.4 7. 974. 77. 6. 3 26.8 4.1 9.8 358. 988. 78. 5. 2 27.8 4.8 9.7 359. 998. 75. 3. 1 28.5 5.2 9.1 1. 1004. 74. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1006. **************************************************** STATION = 9.35N 82.25W PBO 2408212100 787935 **************************************************** PBO 2408212100 FORECAST PROJECTION=15 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.8 6.6 4.9 308. 104. 34. -2. 43 -76.5 6.8 7.8 251. 112. 34. -5. 42 -73.4 8.9 2.7 310. 120. 25. -7. 41 -70.6 9.2 7.0 26. 129. 25. -5. 40 -67.4 11.6 7.3 34. 139. 18. -0. 39 -65.5 10.6 2.4 302. 149. 22. 3. 38 -64.1 5.9 9.2 230. 161. 44. 4. 37 -61.4 4.6 15.4 224. 173. 54. 4. 36 -57.8 4.5 17.2 223. 186. 56. 6. 35 -53.9 4.8 11.3 234. 199. 55. 8. 34 -49.8 4.3 6.7 227. 213. 61. 6. 33 -45.6 4.1 5.6 193. 228. 63. 1. 32 -41.6 3.9 4.0 197. 244. 66. -3. 31 -38.2 3.7 4.2 269. 261. 68. -3. 30 -34.9 8.1 8.7 279. 278. 43. -3. 29 -31.2 11.3 12.2 291. 297. 32. -3. 28 -27.5 10.4 13.9 300. 316. 37. -3. 27 -23.8 8.1 12.4 303. 336. 47. -3. 26 -20.2 5.0 8.7 308. 358. 64. -3. 25 -17.0 4.8 6.5 329. 380. 66. -2. 24 -14.0 6.8 2.7 37. 403. 57. -1. 23 -11.1 6.9 5.5 91. 428. 57. 1. 22 -8.3 6.1 8.3 99. 454. 61. 5. 21 -5.6 8.3 10.2 107. 481. 52. 9. 20 -3.1 10.8 11.5 104. 509. 43. 12. 19 -0.7 9.9 11.4 89. 539. 47. 14. 18 1.6 9.2 11.3 73. 570. 50. 14. 17 4.1 13.6 10.2 64. 602. 37. 11. 16 6.5 14.8 8.6 55. 636. 34. 7. 15 8.7 10.3 8.3 48. 672. 48. -0. 14 10.7 6.8 7.5 49. 709. 63. -8. 13 12.9 5.3 6.1 37. 748. 70. -16. 12 14.9 2.6 6.3 18. 789. 84. -21. 11 16.2 0.7 7.0 10. 821. 96. -22. 10 17.4 0.5 6.3 5. 843. 97. -21. 9 18.8 1.1 5.9 9. 865. 94. -19. 8 20.4 1.9 7.1 24. 887. 89. -15. 7 22.0 2.9 8.5 34. 912. 84. -12. 6 23.7 3.7 8.8 36. 937. 80. -10. 5 24.9 4.3 9.3 25. 957. 77. -8. 4 25.7 4.2 11.1 14. 974. 78. -6. 3 26.5 3.8 10.8 9. 987. 80. -3. 2 27.5 4.4 10.6 10. 998. 77. -1. 1 28.1 4.8 9.8 11. 1004. 75. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1006. **************************************************** STATION = 9.35N 82.25W PBO 2408212200 787935 **************************************************** PBO 2408212200 FORECAST PROJECTION=16 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.1 7.5 8.3 8. 104. 30. -0. 43 -76.2 8.0 9.3 267. 112. 27. -2. 42 -73.9 9.7 8.7 237. 120. 21. -3. 41 -70.8 10.6 4.3 208. 129. 20. -5. 40 -67.7 12.0 2.7 156. 139. 17. -6. 39 -65.0 10.7 3.2 212. 149. 22. -5. 38 -61.9 11.2 9.8 236. 161. 21. -3. 37 -60.5 6.5 10.6 242. 173. 42. -2. 36 -58.3 4.5 8.8 252. 186. 56. -7. 35 -53.9 4.4 8.0 249. 199. 58. -14. 34 -49.6 4.3 8.0 247. 213. 61. -19. 33 -45.4 4.1 8.1 250. 228. 63. -19. 32 -41.4 3.9 7.8 255. 244. 66. -16. 31 -37.8 3.7 8.2 266. 261. 68. -13. 30 -34.7 3.5 9.2 283. 278. 71. -12. 29 -31.2 5.4 10.9 306. 297. 59. -13. 28 -27.6 6.6 13.1 319. 316. 53. -14. 27 -24.0 5.8 12.2 315. 336. 59. -15. 26 -20.5 4.5 9.3 311. 358. 67. -14. 25 -17.2 4.5 7.3 341. 380. 68. -11. 24 -14.1 6.3 7.6 41. 404. 59. -7. 23 -10.9 8.0 9.4 67. 428. 52. -5. 22 -8.1 7.7 10.1 90. 454. 54. -3. 21 -5.6 9.5 11.6 92. 481. 47. -1. 20 -3.1 9.4 13.6 80. 509. 48. -0. 19 -0.5 6.0 14.9 66. 539. 64. -1. 18 1.9 8.2 13.0 58. 570. 54. -3. 17 4.2 14.6 11.4 57. 603. 34. -4. 16 6.6 15.5 9.2 62. 637. 32. 0. 15 8.3 9.2 6.9 62. 672. 52. 6. 14 10.3 5.4 6.8 58. 709. 69. 10. 13 12.7 4.1 6.2 48. 748. 76. 14. 12 14.9 2.1 5.4 13. 789. 87. 19. 11 16.7 1.5 4.8 338. 821. 91. 23. 10 17.6 1.0 3.9 314. 843. 94. 24. 9 18.8 1.2 3.3 320. 865. 93. 23. 8 20.2 1.8 3.4 5. 888. 90. 21. 7 21.7 2.2 5.4 38. 912. 87. 17. 6 23.3 2.8 7.4 37. 937. 84. 13. 5 24.6 3.7 9.6 26. 958. 80. 8. 4 25.4 3.8 11.8 16. 974. 80. 6. 3 25.9 2.9 11.5 4. 987. 84. 5. 2 26.8 3.3 10.8 2. 998. 82. 4. 1 27.3 3.6 9.4 1. 1004. 81. 3. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1006. **************************************************** STATION = 9.35N 82.25W PBO 2408212300 787935 **************************************************** PBO 2408212300 FORECAST PROJECTION=17 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.3 6.0 18.5 60. 104. 38. 1. 43 -75.9 7.2 13.0 37. 112. 32. 2. 42 -73.6 8.5 10.5 18. 120. 27. -1. 41 -71.2 9.5 6.7 359. 129. 23. -4. 40 -68.8 9.4 5.8 309. 139. 25. -5. 39 -66.0 8.6 11.0 273. 150. 29. -5. 38 -63.5 5.5 18.1 257. 161. 47. -5. 37 -60.7 4.6 17.7 252. 173. 54. -5. 36 -57.7 4.5 9.1 257. 186. 56. -4. 35 -54.1 4.4 3.0 278. 199. 58. -1. 34 -49.8 4.3 2.1 238. 213. 61. 2. 33 -45.7 4.1 4.9 219. 228. 63. 5. 32 -41.7 4.6 10.2 235. 244. 61. 9. 31 -37.9 5.2 9.5 261. 261. 58. 14. 30 -34.5 5.8 9.9 296. 278. 55. 17. 29 -31.0 8.1 13.4 317. 297. 45. 18. 28 -27.3 12.3 17.2 318. 316. 30. 18. 27 -23.5 14.1 17.1 317. 337. 26. 18. 26 -20.1 8.8 12.2 316. 358. 46. 17. 25 -17.1 5.1 5.7 327. 380. 65. 17. 24 -14.2 6.3 4.7 63. 404. 59. 16. 23 -11.4 7.9 8.8 77. 428. 52. 14. 22 -8.4 8.8 10.3 91. 454. 49. 9. 21 -5.8 8.8 13.1 97. 481. 50. 4. 20 -3.3 5.7 14.2 86. 510. 65. -2. 19 -1.0 4.0 14.8 69. 539. 74. -6. 18 1.5 8.5 13.2 66. 571. 53. -7. 17 3.8 10.6 11.5 68. 603. 46. -5. 16 6.1 11.7 9.9 69. 637. 43. -2. 15 8.2 8.5 8.2 60. 673. 55. 1. 14 10.0 4.1 7.7 56. 710. 76. 4. 13 12.2 2.7 6.0 42. 749. 83. 6. 12 14.4 1.9 5.9 8. 790. 89. 7. 11 16.2 1.8 6.5 350. 822. 89. 6. 10 17.4 1.8 5.6 345. 844. 89. 4. 9 18.7 1.6 4.2 351. 866. 90. 2. 8 20.2 1.9 3.9 7. 888. 89. 0. 7 22.0 3.0 4.9 28. 913. 83. -1. 6 23.8 4.0 5.9 44. 938. 78. -2. 5 25.3 4.9 5.2 38. 958. 74. -1. 4 26.0 5.0 4.8 347. 975. 74. -0. 3 26.0 3.3 7.8 321. 988. 82. 0. 2 26.5 2.7 6.5 319. 999. 85. 0. 1 27.0 2.9 5.6 317. 1005. 84. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408220000 787935 **************************************************** PBO 2408220000 FORECAST PROJECTION=18 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.2 7.6 9.7 75. 104. 29. 1. 43 -75.4 8.4 4.5 49. 112. 26. 2. 42 -73.4 8.5 5.2 3. 120. 26. 4. 41 -70.8 9.7 4.1 337. 129. 23. 6. 40 -68.0 11.6 3.0 304. 139. 18. 8. 39 -65.2 9.6 6.4 263. 150. 25. 9. 38 -63.3 5.8 12.9 253. 161. 45. 7. 37 -61.0 4.6 15.3 252. 173. 54. 5. 36 -57.8 4.9 9.0 272. 186. 54. 6. 35 -54.1 4.7 4.7 297. 199. 56. 10. 34 -50.1 4.9 4.6 270. 213. 56. 12. 33 -46.1 4.4 10.7 244. 229. 61. 12. 32 -41.8 3.9 13.8 237. 244. 66. 9. 31 -37.8 3.7 9.7 254. 261. 68. 6. 30 -34.5 5.9 9.9 290. 278. 55. 6. 29 -30.9 10.5 13.3 307. 297. 35. 5. 28 -27.3 14.1 17.3 313. 316. 25. 3. 27 -23.7 14.7 16.9 314. 337. 25. 3. 26 -20.2 9.9 11.6 313. 358. 41. 4. 25 -17.0 5.2 4.9 336. 380. 64. 5. 24 -14.1 5.0 7.2 54. 404. 66. 6. 23 -11.4 3.4 11.0 70. 428. 76. 5. 22 -8.7 6.7 12.0 88. 454. 58. 3. 21 -6.1 8.5 13.6 94. 481. 51. 0. 20 -3.5 8.8 14.5 92. 510. 50. -1. 19 -1.0 6.9 14.4 93. 539. 59. 1. 18 1.0 2.4 12.9 88. 571. 84. 5. 17 3.3 2.9 11.9 75. 603. 81. 10. 16 5.8 7.4 11.1 65. 637. 59. 14. 15 8.2 8.1 9.2 59. 673. 57. 17. 14 10.4 4.7 8.4 49. 710. 72. 20. 13 12.4 1.9 6.9 38. 749. 88. 21. 12 14.7 1.3 6.2 16. 790. 92. 21. 11 16.5 2.0 6.1 356. 822. 88. 21. 10 17.4 1.8 5.9 340. 844. 89. 19. 9 18.5 1.4 5.0 335. 867. 92. 15. 8 19.9 1.4 4.3 346. 889. 92. 11. 7 21.6 1.9 4.3 12. 913. 89. 6. 6 23.2 2.4 6.2 28. 938. 86. 2. 5 24.8 3.8 6.8 11. 959. 80. -0. 4 25.9 4.7 6.0 323. 975. 75. 0. 3 26.2 3.8 8.1 313. 989. 80. 2. 2 26.5 2.7 8.6 316. 999. 85. 2. 1 26.4 1.8 5.9 314. 1005. 90. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408220100 787935 **************************************************** PBO 2408220100 FORECAST PROJECTION=19 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.4 7.8 7.8 66. 104. 28. 1. 43 -78.0 4.8 8.9 324. 112. 46. 1. 42 -75.8 5.8 10.1 345. 120. 40. 1. 41 -72.3 7.8 7.5 356. 129. 30. 2. 40 -68.8 8.5 2.9 305. 139. 29. 3. 39 -65.8 7.7 8.6 241. 150. 34. 3. 38 -63.1 6.6 14.7 232. 161. 41. -1. 37 -60.6 5.9 14.3 235. 173. 46. -6. 36 -57.8 5.1 11.4 251. 186. 52. -10. 35 -54.2 5.1 7.2 255. 199. 53. -11. 34 -50.0 6.6 4.2 264. 214. 46. -9. 33 -46.0 6.3 4.7 279. 229. 49. -7. 32 -42.1 4.8 7.5 276. 244. 59. -3. 31 -38.2 3.9 10.7 288. 261. 67. -0. 30 -34.6 5.1 13.4 307. 278. 59. 2. 29 -30.9 9.3 14.6 313. 297. 40. 4. 28 -27.2 11.6 14.7 314. 316. 32. 6. 27 -23.7 12.2 13.6 313. 337. 32. 6. 26 -20.3 8.6 8.8 317. 358. 46. 6. 25 -17.1 5.0 3.3 6. 380. 65. 4. 24 -14.1 4.2 7.1 77. 404. 71. 2. 23 -11.1 6.0 12.5 95. 429. 61. 1. 22 -8.2 8.5 14.8 101. 454. 50. 0. 21 -5.7 9.2 15.9 98. 481. 48. 0. 20 -3.0 9.6 16.3 89. 510. 48. 1. 19 -0.3 9.7 16.5 77. 540. 48. 0. 18 1.8 8.6 15.5 72. 571. 53. -1. 17 3.6 3.2 13.3 71. 603. 80. -3. 16 5.5 1.0 10.3 72. 637. 94. -4. 15 7.9 3.6 8.6 61. 673. 78. -5. 14 10.2 4.6 6.7 46. 710. 73. -6. 13 11.9 1.3 5.4 17. 749. 92. -8. 12 14.1 0.8 6.8 6. 790. 95. -8. 11 15.7 0.9 6.1 349. 822. 95. -7. 10 16.8 0.6 5.6 335. 844. 96. -5. 9 18.0 0.2 4.9 336. 867. 99. -3. 8 19.4 0.2 4.7 347. 889. 99. -2. 7 21.0 0.4 4.8 357. 914. 98. -3. 6 22.8 1.3 5.9 355. 938. 93. -2. 5 24.6 3.5 5.5 316. 959. 81. 2. 4 25.3 3.2 8.7 302. 976. 83. 5. 3 25.7 1.9 11.2 305. 989. 89. 5. 2 26.3 1.8 11.6 305. 1000. 90. 4. 1 26.4 1.5 7.8 302. 1005. 91. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408220200 787935 **************************************************** PBO 2408220200 FORECAST PROJECTION=20 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.0 6.9 16.6 103. 104. 33. 1. 43 -77.5 6.5 6.5 22. 112. 35. 3. 42 -76.1 5.8 9.3 359. 120. 40. 5. 41 -73.3 5.4 9.8 0. 129. 44. 6. 40 -69.9 4.9 6.0 335. 139. 49. 6. 39 -66.9 4.7 11.0 231. 150. 51. 7. 38 -63.8 4.7 21.7 215. 161. 53. 8. 37 -60.5 5.5 21.7 215. 173. 49. 7. 36 -57.2 6.1 16.8 218. 186. 45. 5. 35 -53.9 5.9 9.5 227. 199. 48. 3. 34 -50.2 4.8 6.3 258. 214. 57. 2. 33 -46.2 4.1 4.9 265. 229. 63. 3. 32 -42.2 3.9 5.3 287. 244. 65. 6. 31 -38.3 3.7 7.7 297. 261. 68. 8. 30 -34.6 6.5 11.7 306. 279. 52. 10. 29 -30.9 10.3 15.0 317. 297. 36. 10. 28 -27.3 11.4 15.9 321. 316. 33. 12. 27 -23.9 9.2 13.0 320. 337. 43. 13. 26 -20.9 5.1 6.9 325. 358. 63. 14. 25 -17.8 3.1 3.5 45. 381. 77. 14. 24 -14.6 4.1 8.3 87. 404. 71. 15. 23 -11.6 6.1 12.1 97. 429. 61. 14. 22 -8.9 6.7 13.6 99. 455. 59. 12. 21 -6.5 6.0 14.6 95. 482. 62. 9. 20 -3.7 5.4 15.9 93. 510. 66. 4. 19 -1.0 5.1 15.9 90. 540. 68. -0. 18 1.7 7.7 14.3 83. 571. 56. -3. 17 4.2 10.6 12.4 75. 604. 46. -7. 16 6.1 6.4 10.1 68. 638. 63. -10. 15 7.7 1.7 8.6 64. 673. 89. -13. 14 10.0 1.3 7.9 60. 711. 92. -15. 13 12.7 2.8 7.4 50. 750. 83. -14. 12 15.0 2.7 6.8 26. 791. 84. -11. 11 16.9 2.7 6.9 8. 823. 84. -8. 10 17.8 2.1 6.6 354. 845. 88. -6. 9 18.8 1.9 5.3 344. 867. 89. -5. 8 20.0 1.6 4.6 353. 889. 90. -5. 7 21.4 1.5 5.5 5. 914. 91. -5. 6 23.2 2.4 6.0 4. 939. 86. -4. 5 24.7 3.7 5.1 328. 960. 80. -1. 4 25.5 3.2 7.5 308. 976. 82. 3. 3 25.9 2.4 10.3 307. 989. 87. 4. 2 26.4 1.9 11.1 310. 1000. 89. 4. 1 26.3 1.4 7.3 307. 1006. 92. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408220300 787935 **************************************************** PBO 2408220300 FORECAST PROJECTION=21 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.2 6.7 16.1 94. 104. 34. 2. 43 -75.2 9.2 7.9 67. 112. 23. 6. 42 -73.6 9.7 10.0 14. 120. 21. 9. 41 -72.2 8.3 12.9 357. 129. 28. 9. 40 -69.6 7.2 13.0 349. 139. 35. 8. 39 -66.0 7.8 9.9 334. 150. 33. 5. 38 -62.7 9.0 11.9 240. 161. 29. 2. 37 -59.7 8.5 21.5 218. 173. 32. -0. 36 -56.4 7.8 22.0 223. 186. 37. -4. 35 -53.1 9.0 19.2 229. 199. 33. -7. 34 -49.8 8.5 11.8 230. 214. 36. -10. 33 -46.1 5.9 6.5 241. 229. 51. -11. 32 -42.1 4.9 5.9 243. 244. 58. -11. 31 -38.2 5.0 6.1 253. 261. 59. -9. 30 -34.5 6.1 7.4 285. 279. 54. -7. 29 -30.9 9.8 11.0 308. 297. 38. -4. 28 -27.5 10.0 13.6 312. 316. 38. -3. 27 -24.4 6.2 12.7 309. 337. 56. -2. 26 -21.0 4.8 8.2 308. 358. 66. -2. 25 -17.7 3.8 1.6 332. 381. 72. -3. 24 -14.5 4.8 4.9 95. 404. 67. -4. 23 -11.4 6.2 9.3 99. 429. 60. -5. 22 -8.6 6.0 12.4 94. 455. 62. -5. 21 -6.0 6.3 14.8 85. 482. 61. -5. 20 -3.1 7.5 16.6 80. 510. 56. -2. 19 -0.2 9.3 17.2 80. 540. 50. 1. 18 2.4 10.0 17.1 82. 571. 48. 5. 17 4.8 9.4 16.1 81. 604. 51. 8. 16 7.1 10.1 14.3 76. 638. 49. 7. 15 9.0 8.9 12.6 70. 673. 54. 4. 14 10.5 4.1 10.4 62. 711. 76. -2. 13 11.9 0.7 8.3 51. 750. 95. -7. 12 14.0 1.0 7.3 33. 791. 94. -12. 11 15.5 0.4 6.0 357. 823. 97. -14. 10 16.8 0.1 5.6 328. 845. 100. -13. 9 17.9 0.1 5.2 318. 867. 100. -11. 8 19.1 0.1 4.9 333. 890. 100. -10. 7 20.8 0.7 5.7 348. 914. 96. -9. 6 22.8 2.0 6.0 344. 939. 89. -4. 5 24.4 2.9 6.9 319. 960. 84. 3. 4 25.1 2.5 9.9 310. 976. 86. 7. 3 25.8 2.1 12.0 309. 990. 88. 6. 2 26.3 1.9 12.3 307. 1000. 89. 4. 1 26.2 1.2 7.8 304. 1006. 93. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408220400 787935 **************************************************** PBO 2408220400 FORECAST PROJECTION=22 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.7 7.5 9.9 106. 104. 29. -0. 43 -74.0 10.2 3.3 86. 112. 20. -1. 42 -72.4 11.4 5.0 327. 120. 17. -0. 41 -71.5 8.9 12.6 336. 129. 26. 1. 40 -69.8 6.4 16.0 344. 139. 39. 1. 39 -66.8 5.6 12.6 336. 150. 45. 1. 38 -63.8 4.8 8.3 264. 161. 52. -0. 37 -61.0 4.6 15.1 215. 173. 54. -1. 36 -57.3 4.5 20.2 205. 186. 56. -1. 35 -53.4 7.8 19.5 211. 199. 38. 1. 34 -49.7 9.7 16.3 224. 214. 31. 3. 33 -46.0 7.8 12.0 235. 229. 41. 6. 32 -42.2 5.4 8.4 242. 244. 56. 8. 31 -38.4 5.4 8.7 253. 261. 56. 8. 30 -34.6 8.3 9.6 272. 279. 43. 8. 29 -30.9 11.3 11.4 290. 297. 32. 7. 28 -27.5 11.5 12.7 297. 316. 33. 4. 27 -24.2 8.1 11.4 300. 337. 47. -0. 26 -20.9 5.4 7.8 306. 358. 62. -5. 25 -17.6 4.7 3.8 328. 381. 67. -11. 24 -14.3 5.7 3.3 41. 404. 62. -16. 23 -11.3 6.3 8.3 72. 429. 60. -18. 22 -8.7 5.8 13.3 79. 455. 63. -16. 21 -6.0 5.9 16.4 83. 482. 63. -13. 20 -3.4 5.7 17.4 89. 510. 65. -8. 19 -1.0 4.3 17.6 93. 540. 72. -3. 18 1.5 5.4 16.0 92. 571. 67. 3. 17 3.8 8.0 14.3 82. 604. 56. 6. 16 6.0 8.1 13.7 73. 638. 56. 6. 15 8.3 7.5 13.0 62. 674. 59. 4. 14 10.4 5.7 11.7 49. 711. 68. 3. 13 12.1 2.3 9.1 37. 750. 86. 1. 12 14.1 1.0 7.1 31. 791. 93. -1. 11 15.8 1.0 5.6 21. 823. 94. -4. 10 17.0 0.8 4.5 2. 845. 95. -6. 9 18.3 0.9 4.2 316. 867. 94. -8. 8 19.6 1.2 3.8 291. 890. 93. -8. 7 21.1 1.4 3.0 304. 914. 91. -9. 6 22.7 1.5 3.6 346. 939. 91. -8. 5 24.2 2.0 4.5 359. 960. 89. -5. 4 25.4 2.9 5.5 333. 976. 84. -2. 3 25.9 2.7 8.0 317. 990. 85. 1. 2 26.3 2.3 10.3 308. 1000. 87. 1. 1 26.0 1.3 6.1 309. 1006. 93. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408220500 787935 **************************************************** PBO 2408220500 FORECAST PROJECTION=23 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.6 7.8 13.9 88. 104. 28. 1. 43 -74.9 9.5 3.8 33. 112. 22. 4. 42 -73.9 7.8 8.5 358. 120. 29. 6. 41 -72.4 6.2 14.0 4. 129. 39. 6. 40 -70.1 5.5 14.1 6. 139. 44. 5. 39 -67.3 5.2 8.2 0. 150. 48. 3. 38 -63.7 6.5 4.7 226. 161. 41. 2. 37 -60.2 7.0 17.2 194. 173. 40. 2. 36 -56.6 6.8 22.0 187. 186. 42. 4. 35 -52.9 8.6 19.0 193. 199. 35. 6. 34 -49.3 9.5 16.7 212. 214. 32. 5. 33 -45.6 11.8 16.3 230. 229. 25. 2. 32 -41.7 11.8 14.0 243. 244. 27. -0. 31 -38.0 10.6 10.5 254. 261. 32. 0. 30 -34.2 11.4 8.6 271. 279. 31. 1. 29 -30.5 13.2 10.1 294. 297. 26. 2. 28 -27.1 11.1 13.1 308. 316. 34. 4. 27 -23.6 9.9 14.2 316. 337. 40. 5. 26 -20.1 9.6 12.1 322. 358. 42. 6. 25 -16.9 8.0 8.1 338. 380. 50. 7. 24 -13.7 7.9 6.0 24. 404. 51. 7. 23 -10.8 8.7 10.0 67. 429. 49. 6. 22 -8.3 8.2 14.4 79. 454. 52. 5. 21 -6.0 8.2 16.6 91. 481. 52. 2. 20 -3.8 5.7 18.4 99. 510. 65. -0. 19 -1.6 1.8 18.1 97. 540. 88. -2. 18 0.6 0.9 15.9 91. 571. 94. -3. 17 3.2 4.4 13.2 84. 603. 73. -3. 16 5.6 7.9 11.4 68. 637. 57. -4. 15 7.6 6.6 11.5 49. 673. 63. -7. 14 9.8 4.7 11.9 36. 710. 73. -11. 13 12.1 3.0 10.7 27. 749. 82. -12. 12 14.5 2.1 8.5 18. 790. 87. -9. 11 16.4 2.5 6.1 1. 822. 85. -5. 10 17.1 1.3 5.0 330. 844. 92. -2. 9 18.2 0.7 5.6 305. 867. 96. -2. 8 19.6 0.8 5.6 292. 889. 95. -2. 7 21.0 1.1 4.4 292. 913. 93. -1. 6 22.7 1.7 2.6 309. 938. 90. 0. 5 24.2 1.9 2.6 331. 959. 89. 1. 4 25.3 2.6 3.4 311. 976. 86. 1. 3 25.8 2.6 7.3 297. 989. 86. 1. 2 26.2 2.0 10.3 294. 1000. 89. 1. 1 25.9 1.3 7.0 279. 1005. 92. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408220600 787935 **************************************************** PBO 2408220600 FORECAST PROJECTION=24 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.3 6.4 12.7 100. 104. 35. 0. 43 -76.2 7.6 7.2 84. 112. 30. -2. 42 -74.8 6.4 8.3 39. 120. 37. -4. 41 -73.0 5.4 9.6 355. 129. 44. -6. 40 -70.9 4.7 12.2 334. 139. 50. -5. 39 -67.8 4.7 11.2 325. 149. 51. -4. 38 -64.3 4.8 9.0 267. 161. 52. -3. 37 -61.1 4.7 14.7 205. 173. 54. -3. 36 -57.3 5.0 20.2 190. 186. 53. -3. 35 -53.3 4.6 19.2 186. 199. 57. -4. 34 -49.3 6.8 15.7 202. 213. 45. -4. 33 -45.5 11.8 15.1 225. 228. 25. -3. 32 -41.8 13.8 13.5 250. 244. 21. -4. 31 -38.1 11.9 11.5 266. 261. 27. -5. 30 -34.3 11.7 9.2 277. 278. 30. -7. 29 -30.6 12.6 9.2 299. 297. 28. -9. 28 -27.2 10.7 10.4 313. 316. 36. -11. 27 -24.1 7.4 10.4 325. 336. 50. -14. 26 -20.9 5.8 9.2 334. 358. 60. -17. 25 -17.7 5.8 6.0 3. 380. 60. -18. 24 -14.4 7.6 8.7 56. 404. 53. -16. 23 -11.1 9.3 14.3 70. 428. 46. -14. 22 -8.4 8.1 15.5 79. 454. 52. -15. 21 -5.9 5.7 16.5 87. 481. 64. -18. 20 -3.3 4.8 15.4 88. 510. 70. -20. 19 -1.1 2.1 12.3 77. 539. 85. -21. 18 0.9 1.0 11.6 69. 571. 93. -21. 17 3.1 2.4 13.0 72. 603. 84. -18. 16 5.8 5.9 12.8 73. 637. 66. -13. 15 8.5 8.4 10.4 64. 673. 56. -9. 14 10.7 7.9 9.4 52. 710. 58. -8. 13 12.8 5.7 8.2 45. 749. 68. -8. 12 14.9 3.1 4.7 28. 790. 82. -7. 11 16.6 2.8 3.4 348. 822. 84. -5. 10 17.6 2.4 4.3 320. 844. 86. -4. 9 18.6 1.8 5.7 306. 866. 89. -4. 8 19.8 1.6 6.3 303. 888. 90. -5. 7 21.2 1.7 5.4 313. 913. 90. -6. 6 22.6 1.5 3.7 339. 938. 91. -6. 5 23.9 1.6 3.9 345. 958. 91. -4. 4 24.8 1.7 6.3 322. 975. 90. -2. 3 25.3 1.6 10.5 314. 988. 91. -0. 2 25.6 1.6 11.4 311. 999. 91. 0. 1 25.4 1.6 6.8 302. 1005. 91. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408220700 787935 **************************************************** PBO 2408220700 FORECAST PROJECTION=25 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.9 7.0 11.5 75. 104. 32. -0. 43 -75.3 9.3 10.0 106. 112. 22. -2. 42 -73.0 10.4 10.0 126. 120. 19. -4. 41 -70.7 10.6 5.0 127. 129. 20. -6. 40 -68.6 10.2 2.6 325. 139. 22. -6. 39 -66.5 8.5 7.0 324. 149. 29. -6. 38 -63.8 7.3 6.9 320. 161. 37. -5. 37 -60.5 7.0 4.6 263. 173. 39. -5. 36 -57.1 6.2 9.6 201. 186. 45. -5. 35 -53.5 5.4 14.2 187. 199. 51. -5. 34 -49.5 6.1 13.9 187. 213. 48. -4. 33 -45.4 9.5 10.1 211. 228. 34. -2. 32 -41.8 13.5 7.9 256. 244. 22. 1. 31 -38.2 13.0 9.0 296. 261. 24. 4. 30 -34.6 11.4 10.5 312. 278. 31. 5. 29 -31.0 9.2 12.5 323. 297. 40. 6. 28 -27.3 7.3 15.5 330. 316. 50. 6. 27 -23.8 6.0 16.4 330. 336. 58. 4. 26 -20.5 6.4 12.9 324. 358. 56. 3. 25 -17.3 7.5 6.0 330. 380. 52. 3. 24 -14.1 9.6 4.1 54. 403. 44. 3. 23 -11.4 8.1 7.9 91. 428. 51. 3. 22 -9.0 5.8 13.1 101. 454. 63. 5. 21 -6.2 6.9 16.5 102. 481. 58. 5. 20 -3.4 7.4 16.3 99. 509. 56. 4. 19 -1.0 5.1 13.7 95. 539. 68. 0. 18 1.3 2.3 10.8 90. 570. 85. -5. 17 3.3 1.0 11.8 79. 603. 93. -10. 16 5.6 2.2 13.7 69. 637. 86. -15. 15 8.5 6.2 13.7 62. 672. 65. -18. 14 11.3 9.0 12.8 53. 710. 54. -19. 13 13.5 8.2 10.2 44. 748. 58. -15. 12 15.3 4.4 7.5 28. 789. 75. -9. 11 16.9 3.4 5.1 1. 821. 80. -4. 10 18.0 3.4 6.0 327. 843. 80. -1. 9 19.2 3.5 7.5 315. 865. 80. 1. 8 20.4 3.3 8.1 311. 888. 81. 1. 7 21.6 2.7 7.3 311. 912. 84. 1. 6 22.8 2.0 5.3 314. 937. 88. 1. 5 23.9 1.7 5.3 317. 958. 90. 1. 4 24.8 1.6 7.2 317. 974. 91. 2. 3 25.1 1.4 11.7 313. 988. 92. 4. 2 25.2 1.0 12.5 306. 998. 94. 3. 1 25.0 1.0 8.1 300. 1004. 94. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1006. **************************************************** STATION = 9.35N 82.25W PBO 2408220800 787935 **************************************************** PBO 2408220800 FORECAST PROJECTION=26 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.6 6.4 8.0 342. 104. 35. 1. 43 -77.0 7.4 1.1 326. 112. 30. 2. 42 -74.3 8.2 2.8 56. 120. 27. 3. 41 -71.6 9.3 5.6 44. 129. 24. 4. 40 -69.0 9.5 9.5 27. 139. 24. 4. 39 -66.6 8.4 12.6 17. 149. 30. 3. 38 -63.7 7.2 12.0 7. 161. 37. 3. 37 -60.5 7.2 7.4 348. 173. 38. 3. 36 -56.9 7.9 3.2 257. 186. 36. 5. 35 -53.5 6.5 9.6 199. 199. 45. 7. 34 -49.8 6.7 14.2 192. 213. 45. 9. 33 -45.7 9.2 13.5 194. 228. 35. 11. 32 -41.7 13.1 9.8 207. 244. 23. 12. 31 -37.7 15.9 6.6 236. 261. 17. 12. 30 -33.9 14.6 5.6 279. 278. 22. 13. 29 -30.2 12.1 6.6 308. 297. 30. 13. 28 -26.6 10.1 9.0 317. 316. 38. 13. 27 -23.2 8.8 10.8 320. 336. 44. 14. 26 -20.0 8.5 10.5 325. 358. 47. 16. 25 -16.8 9.7 8.1 334. 380. 43. 18. 24 -13.5 11.7 4.6 4. 403. 37. 20. 23 -10.5 11.4 5.3 72. 428. 39. 21. 22 -7.9 8.7 9.7 94. 454. 50. 22. 21 -5.9 5.0 14.0 97. 481. 68. 20. 20 -4.0 4.0 16.1 95. 509. 73. 16. 19 -1.7 3.5 14.6 91. 539. 77. 11. 18 0.6 2.1 12.9 89. 570. 86. 5. 17 2.8 0.6 12.4 84. 603. 96. -2. 16 4.8 0.9 12.7 74. 637. 94. -8. 15 7.2 3.6 12.0 63. 672. 78. -14. 14 9.5 4.6 9.6 47. 710. 73. -17. 13 11.4 1.5 6.9 19. 749. 91. -18. 12 13.9 0.0 5.2 335. 789. 100. -17. 11 15.4 0.8 7.3 321. 821. 95. -16. 10 16.6 0.6 8.1 330. 844. 96. -15. 9 17.9 0.7 8.1 336. 866. 96. -15. 8 19.2 0.6 7.6 342. 888. 96. -16. 7 20.7 0.7 7.2 348. 913. 96. -15. 6 22.3 0.9 7.3 348. 937. 95. -12. 5 23.6 1.2 7.5 339. 958. 93. -8. 4 24.4 1.3 9.0 321. 975. 92. -3. 3 24.9 1.5 12.4 311. 988. 92. 0. 2 24.9 1.1 12.1 304. 999. 93. 1. 1 24.9 1.2 7.5 301. 1004. 93. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408220900 787935 **************************************************** PBO 2408220900 FORECAST PROJECTION=27 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -79.4 5.4 12.7 218. 104. 41. 1. 43 -78.8 4.9 13.0 192. 112. 45. 4. 42 -76.7 4.8 7.2 172. 120. 47. 6. 41 -74.3 4.7 5.1 75. 129. 49. 7. 40 -71.8 4.7 14.4 38. 139. 49. 7. 39 -68.5 4.7 20.5 28. 149. 51. 7. 38 -64.6 4.7 15.8 16. 161. 53. 6. 37 -60.7 4.7 10.3 3. 173. 54. 3. 36 -56.7 8.5 3.5 320. 186. 33. -1. 35 -52.8 10.7 7.4 218. 199. 26. -4. 34 -48.8 13.8 11.6 204. 213. 18. -6. 33 -45.0 14.9 12.3 192. 228. 17. -6. 32 -41.1 15.4 10.1 194. 244. 17. -5. 31 -37.2 17.7 4.9 226. 261. 14. -1. 30 -33.5 17.2 4.5 310. 278. 16. 3. 29 -30.0 13.7 7.9 335. 297. 25. 7. 28 -26.6 11.6 11.5 334. 316. 32. 10. 27 -23.4 10.2 13.4 331. 336. 39. 11. 26 -20.3 9.2 11.8 339. 358. 44. 10. 25 -17.0 10.0 8.7 354. 380. 41. 6. 24 -13.6 12.1 5.9 20. 403. 35. 3. 23 -10.7 10.3 4.9 71. 428. 43. 1. 22 -8.6 5.7 7.9 102. 454. 63. 2. 21 -6.7 6.1 12.1 100. 481. 62. 5. 20 -4.5 5.9 15.4 96. 509. 64. 9. 19 -2.1 3.3 15.2 89. 539. 78. 13. 18 0.0 1.1 13.1 81. 570. 93. 14. 17 2.3 0.3 13.6 75. 603. 98. 10. 16 4.7 0.9 13.9 73. 637. 94. 2. 15 7.1 2.8 10.9 68. 672. 82. -8. 14 9.3 4.2 7.5 50. 710. 75. -18. 13 11.6 3.5 5.8 19. 749. 79. -26. 12 14.1 2.2 5.9 352. 789. 87. -32. 11 15.5 0.7 7.3 340. 821. 96. -34. 10 16.9 1.0 8.6 338. 844. 94. -33. 9 18.1 1.1 9.5 336. 866. 93. -31. 8 19.5 1.2 9.9 338. 888. 93. -27. 7 21.0 1.3 10.0 342. 913. 92. -22. 6 22.4 1.2 10.4 345. 937. 93. -16. 5 23.5 1.1 11.1 342. 958. 93. -9. 4 24.5 1.6 11.8 331. 975. 91. -5. 3 25.2 2.1 13.4 320. 988. 88. -1. 2 25.4 2.0 13.3 316. 999. 89. 1. 1 24.9 1.2 7.9 322. 1004. 93. 1. PRCP(HR)=.004 PRCP(TOT)= 0.004 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408221000 787935 **************************************************** PBO 2408221000 FORECAST PROJECTION=28 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -79.7 4.9 4.9 263. 104. 44. -0. 43 -79.0 4.7 7.2 196. 112. 47. -2. 42 -76.4 4.8 5.3 163. 120. 47. -5. 41 -73.8 4.7 5.7 114. 129. 48. -8. 40 -71.5 4.7 12.1 62. 139. 50. -11. 39 -68.7 4.7 20.4 43. 149. 51. -13. 38 -65.0 4.7 17.4 31. 161. 52. -15. 37 -60.9 4.6 8.9 13. 173. 54. -17. 36 -56.8 7.7 2.7 299. 186. 37. -19. 35 -52.8 12.2 6.1 225. 199. 21. -20. 34 -48.9 14.0 9.0 214. 213. 18. -21. 33 -45.0 14.5 9.9 211. 228. 18. -21. 32 -41.2 15.0 9.0 210. 244. 18. -21. 31 -37.3 17.1 6.3 230. 261. 15. -21. 30 -33.3 18.7 5.2 304. 278. 13. -23. 29 -29.6 16.7 9.0 341. 297. 18. -24. 28 -26.3 14.0 13.0 342. 316. 26. -23. 27 -23.3 11.7 14.5 337. 336. 33. -20. 26 -20.4 10.1 12.6 342. 358. 40. -17. 25 -17.6 9.4 9.1 3. 380. 44. -14. 24 -14.7 8.5 6.9 35. 404. 48. -10. 23 -12.3 6.7 7.3 76. 428. 57. -4. 22 -9.6 6.2 12.4 98. 454. 61. 4. 21 -6.6 4.9 15.9 99. 481. 68. 11. 20 -4.0 3.9 17.9 94. 509. 74. 16. 19 -1.7 3.6 19.1 86. 539. 77. 20. 18 0.6 2.6 17.7 81. 570. 83. 22. 17 2.9 1.5 16.4 81. 603. 90. 22. 16 5.4 1.5 15.8 77. 637. 90. 19. 15 7.8 2.8 13.9 67. 673. 83. 14. 14 10.0 4.7 8.6 49. 710. 73. 8. 13 12.0 4.4 5.6 9. 749. 75. 4. 12 14.0 2.8 7.3 334. 790. 83. -2. 11 15.5 1.5 9.2 327. 821. 91. -8. 10 16.6 0.9 9.7 327. 844. 95. -12. 9 17.9 0.8 9.2 330. 866. 95. -15. 8 19.1 0.6 8.7 335. 888. 96. -19. 7 20.5 0.7 9.2 338. 913. 96. -20. 6 22.0 0.8 10.4 337. 938. 95. -18. 5 23.1 0.9 12.6 339. 958. 95. -11. 4 24.1 0.9 14.2 339. 975. 95. -4. 3 24.9 1.0 14.3 334. 988. 94. 1. 2 25.3 1.5 12.8 322. 999. 91. 2. 1 24.9 1.2 7.8 317. 1005. 93. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408221100 787935 **************************************************** PBO 2408221100 FORECAST PROJECTION=29 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.7 6.0 14.7 301. 104. 38. -1. 43 -77.2 6.9 12.4 256. 112. 32. -4. 42 -75.7 6.4 11.4 229. 120. 36. -5. 41 -73.7 5.5 5.7 179. 129. 43. -5. 40 -71.5 4.7 12.7 82. 139. 49. -3. 39 -68.8 4.7 18.6 62. 150. 51. -0. 38 -65.2 4.7 14.5 43. 161. 52. 2. 37 -61.1 4.6 6.3 17. 173. 54. 4. 36 -57.1 4.7 2.8 279. 186. 55. 7. 35 -53.1 11.0 5.0 252. 199. 25. 9. 34 -49.2 12.7 5.2 245. 213. 21. 11. 33 -45.3 13.9 4.5 255. 228. 20. 12. 32 -41.5 15.1 4.8 294. 244. 18. 12. 31 -37.6 15.4 6.6 335. 261. 19. 12. 30 -33.9 13.5 11.0 352. 278. 24. 12. 29 -30.3 12.3 14.8 349. 297. 29. 12. 28 -26.8 11.2 16.8 339. 316. 34. 12. 27 -23.7 9.9 16.2 331. 337. 40. 9. 26 -20.6 10.0 13.2 329. 358. 40. 4. 25 -17.4 10.7 7.2 336. 380. 39. 0. 24 -14.6 9.9 3.1 32. 404. 43. -2. 23 -11.9 9.1 6.1 89. 428. 47. -5. 22 -8.8 9.1 9.6 95. 454. 48. -9. 21 -6.1 7.1 11.9 105. 481. 57. -14. 20 -4.2 3.2 14.2 107. 510. 78. -17. 19 -2.1 0.7 14.8 101. 539. 95. -19. 18 0.1 0.1 13.9 94. 571. 99. -19. 17 2.3 0.2 12.1 87. 603. 99. -16. 16 4.9 0.7 10.9 77. 637. 95. -9. 15 7.2 1.2 10.7 55. 673. 92. -0. 14 9.4 1.2 11.8 32. 710. 92. 10. 13 11.8 2.1 9.2 356. 749. 87. 27. 12 13.9 1.2 7.7 333. 790. 92. 42. 11 15.4 0.5 6.7 337. 822. 97. 44. 10 16.7 0.0 7.4 349. 844. 100. 31. 9 17.9 0.0 9.1 358. 867. 100. 14. 8 19.1 0.2 10.0 358. 889. 99. 3. 7 20.3 0.1 10.7 351. 914. 99. 1. 6 21.8 0.6 11.8 353. 938. 96. 5. 5 23.5 2.8 15.1 20. 959. 84. 8. 4 24.8 4.4 17.0 30. 976. 76. 6. 3 25.3 4.4 15.1 28. 989. 77. 3. 2 24.8 2.4 11.7 9. 1000. 87. 2. 1 24.8 1.8 8.8 0. 1005. 90. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408221200 787935 **************************************************** PBO 2408221200 FORECAST PROJECTION=30 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.8 6.0 21.6 85. 104. 37. 1. 43 -77.2 7.0 12.3 109. 112. 32. 2. 42 -75.0 7.7 7.0 150. 120. 30. 3. 41 -72.3 8.9 4.7 162. 129. 25. 4. 40 -69.3 10.9 6.1 90. 139. 19. 2. 39 -66.6 11.2 11.6 60. 150. 19. -1. 38 -64.7 5.1 11.0 32. 161. 49. -5. 37 -61.3 4.6 8.6 346. 173. 54. -9. 36 -57.2 4.5 10.2 308. 186. 56. -12. 35 -53.2 8.5 10.7 292. 199. 35. -12. 34 -49.2 12.3 10.3 288. 214. 23. -11. 33 -45.2 14.9 9.7 293. 229. 17. -8. 32 -41.2 17.0 9.2 309. 244. 14. -4. 31 -37.4 17.4 9.2 340. 261. 15. -0. 30 -33.7 13.3 11.3 4. 278. 25. 3. 29 -30.4 8.0 12.5 14. 297. 45. 4. 28 -27.2 4.7 12.2 12. 316. 64. 2. 27 -24.3 3.7 11.3 4. 337. 71. -2. 26 -21.1 6.6 9.8 355. 358. 56. -7. 25 -17.8 9.5 7.8 6. 380. 43. -9. 24 -14.7 10.0 7.3 47. 404. 42. -10. 23 -11.6 10.3 9.7 80. 428. 42. -11. 22 -8.5 8.4 10.3 95. 454. 51. -13. 21 -6.1 5.1 11.2 104. 481. 67. -12. 20 -3.8 4.0 13.6 106. 510. 74. -7. 19 -1.1 4.8 15.4 112. 540. 70. 4. 18 1.3 4.6 15.2 119. 571. 71. 14. 17 3.4 2.9 14.6 119. 603. 82. 22. 16 5.3 1.2 12.2 108. 637. 92. 23. 15 7.7 2.7 14.4 60. 673. 83. 19. 14 9.0 0.7 13.2 47. 710. 95. 15. 13 11.3 0.1 8.3 24. 750. 99. 17. 12 13.7 0.8 8.6 353. 790. 95. 22. 11 15.0 0.0 11.2 347. 822. 100. 23. 10 16.2 0.0 13.0 350. 845. 100. 19. 9 17.1 0.1 14.5 352. 867. 99. 14. 8 18.4 0.4 15.3 352. 889. 98. 11. 7 19.8 0.4 15.2 357. 914. 98. 9. 6 21.0 0.1 13.9 10. 939. 100. 7. 5 22.0 0.8 14.3 5. 959. 95. 1. 4 23.6 2.6 14.4 359. 976. 85. -4. 3 24.6 3.3 12.3 347. 989. 82. -3. 2 24.9 2.4 9.0 328. 1000. 86. -0. 1 25.2 2.1 7.0 323. 1006. 88. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408221300 787935 **************************************************** PBO 2408221300 FORECAST PROJECTION=31 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -80.6 4.6 20.0 195. 104. 46. -1. 43 -80.4 4.7 16.3 220. 112. 46. -5. 42 -78.0 4.7 10.8 242. 120. 47. -5. 41 -75.1 4.7 10.8 333. 129. 48. -1. 40 -71.4 4.7 16.6 348. 139. 49. 6. 39 -68.0 4.7 14.2 350. 150. 51. 8. 38 -64.6 4.7 13.0 346. 161. 53. 8. 37 -61.1 4.6 12.4 336. 173. 54. 8. 36 -57.3 5.1 12.0 322. 186. 52. 6. 35 -53.3 7.1 12.2 311. 199. 42. 5. 34 -49.3 11.1 11.1 308. 214. 26. 5. 33 -45.4 14.4 9.8 314. 229. 18. 6. 32 -41.5 11.7 10.0 333. 244. 27. 7. 31 -37.7 7.0 12.4 355. 261. 48. 9. 30 -34.0 4.3 15.9 11. 279. 65. 11. 29 -30.3 4.1 17.6 18. 297. 68. 13. 28 -26.6 4.1 16.6 20. 316. 68. 14. 27 -23.0 4.5 14.2 19. 337. 66. 15. 26 -20.3 4.6 9.7 15. 358. 67. 16. 25 -17.8 7.5 4.3 36. 381. 52. 18. 24 -15.1 4.9 5.4 110. 404. 66. 16. 23 -12.1 1.0 6.1 122. 429. 92. 7. 22 -9.9 0.5 8.2 137. 455. 96. 1. 21 -7.4 1.9 14.4 129. 482. 86. 3. 20 -4.5 3.1 16.0 114. 510. 79. 5. 19 -2.0 0.6 15.2 106. 540. 95. 4. 18 0.4 0.2 9.9 95. 571. 98. 1. 17 2.5 0.8 10.2 59. 604. 95. -5. 16 5.3 2.4 14.3 39. 638. 84. -8. 15 7.7 3.4 17.7 31. 674. 79. -4. 14 9.3 2.4 17.4 32. 711. 85. 4. 13 11.3 1.9 14.7 36. 750. 88. 9. 12 14.1 2.5 12.8 41. 791. 85. 6. 11 16.4 2.6 12.4 39. 823. 84. -2. 10 17.2 1.5 12.3 26. 845. 91. -8. 9 17.9 0.9 13.1 9. 867. 95. -12. 8 19.2 1.4 13.5 352. 890. 92. -14. 7 20.7 2.0 12.9 347. 914. 88. -17. 6 21.9 2.4 12.8 350. 939. 86. -21. 5 22.7 2.3 13.5 349. 960. 87. -22. 4 23.4 2.1 13.9 343. 976. 88. -19. 3 24.4 2.5 13.3 336. 990. 86. -13. 2 25.1 2.8 11.5 329. 1000. 84. -6. 1 25.5 2.7 8.6 323. 1006. 85. -1. PRCP(HR)=.005 PRCP(TOT)= 0.005 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408221400 787935 **************************************************** PBO 2408221400 FORECAST PROJECTION=32 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.8 4.7 15.4 111. 104. 46. 0. 43 -76.9 6.8 15.3 85. 112. 34. -1. 42 -75.2 8.6 14.7 71. 120. 25. -4. 41 -72.9 10.1 11.2 54. 129. 21. -7. 40 -70.0 11.5 10.8 16. 139. 17. -8. 39 -66.7 11.1 13.1 355. 150. 20. -9. 38 -63.5 6.9 11.3 343. 161. 39. -11. 37 -60.6 4.6 7.9 319. 173. 54. -16. 36 -57.3 4.5 9.1 294. 186. 56. -20. 35 -53.4 4.4 11.6 291. 199. 58. -23. 34 -49.4 4.3 12.3 297. 214. 61. -23. 33 -45.4 4.1 11.8 309. 229. 63. -20. 32 -41.6 3.9 10.4 329. 244. 66. -17. 31 -37.9 3.7 10.1 355. 261. 68. -15. 30 -34.2 3.4 11.3 16. 279. 71. -12. 29 -30.6 3.2 14.5 37. 297. 74. -7. 28 -26.8 3.7 19.5 58. 316. 71. -0. 27 -23.1 4.9 22.1 64. 337. 64. 7. 26 -19.7 5.2 17.0 57. 358. 63. 12. 25 -16.7 4.3 10.6 30. 381. 69. 14. 24 -14.1 3.6 3.9 6. 404. 74. 16. 23 -11.8 3.5 2.9 154. 429. 75. 17. 22 -9.4 4.9 14.8 124. 455. 67. 15. 21 -6.3 5.0 21.2 113. 482. 68. 8. 20 -3.8 4.6 21.5 109. 510. 71. -2. 19 -1.6 5.0 20.0 106. 540. 69. -13. 18 1.1 5.4 18.4 105. 571. 67. -21. 17 3.5 4.3 18.0 112. 604. 73. -26. 16 5.7 2.2 18.8 118. 638. 86. -30. 15 7.6 0.8 15.5 108. 674. 95. -33. 14 10.0 2.6 9.7 72. 711. 84. -35. 13 11.7 2.4 10.2 44. 750. 85. -34. 12 13.6 1.7 10.5 32. 791. 89. -29. 11 15.6 2.4 8.6 29. 823. 86. -22. 10 17.0 2.9 7.1 31. 845. 83. -18. 9 18.4 3.0 5.5 27. 867. 83. -14. 8 19.6 2.8 4.7 351. 890. 84. -10. 7 20.9 2.8 7.5 297. 914. 84. -4. 6 21.9 2.3 10.6 285. 939. 87. 3. 5 22.2 1.3 12.6 291. 960. 92. 6. 4 22.5 0.6 15.5 300. 976. 97. 7. 3 23.0 0.3 15.2 292. 990. 98. 6. 2 24.0 1.0 14.4 289. 1000. 94. 4. 1 24.7 1.5 13.2 287. 1006. 92. 2. PRCP(HR)=.002 PRCP(TOT)= 0.002 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408221500 787935 **************************************************** PBO 2408221500 FORECAST PROJECTION=33 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.8 6.0 20.0 122. 104. 38. -2. 43 -75.7 6.5 22.7 112. 112. 36. -5. 42 -73.4 7.9 21.3 101. 120. 29. -7. 41 -70.5 11.1 16.3 95. 129. 18. -6. 40 -67.8 12.2 9.5 81. 139. 16. -4. 39 -65.9 7.7 5.2 48. 150. 34. -3. 38 -64.3 4.6 6.1 15. 161. 53. -5. 37 -61.4 4.6 9.5 4. 173. 54. -8. 36 -57.4 4.5 12.1 357. 186. 56. -10. 35 -53.4 5.1 13.7 349. 199. 53. -9. 34 -49.3 8.2 13.1 339. 214. 38. -7. 33 -45.3 9.0 12.2 327. 229. 35. -7. 32 -41.4 8.7 10.8 326. 244. 38. -8. 31 -37.5 8.4 8.5 355. 261. 41. -10. 30 -33.6 8.0 11.8 46. 279. 44. -10. 29 -29.7 9.4 17.1 66. 297. 40. -11. 28 -26.0 9.1 20.2 77. 316. 42. -13. 27 -22.8 7.1 18.8 80. 337. 52. -18. 26 -20.0 4.5 12.0 73. 358. 68. -24. 25 -17.6 2.4 4.1 44. 380. 81. -30. 24 -15.3 2.8 3.0 213. 404. 79. -30. 23 -12.2 4.8 8.9 160. 429. 68. -25. 22 -8.7 5.8 14.4 127. 455. 63. -18. 21 -6.0 4.2 18.2 115. 482. 72. -12. 20 -3.8 3.3 19.6 108. 510. 78. -6. 19 -1.4 3.3 18.3 104. 540. 78. -2. 18 0.9 3.0 15.1 99. 571. 81. 2. 17 3.2 2.4 11.6 96. 604. 84. 7. 16 5.5 1.6 11.3 95. 638. 90. 13. 15 7.7 1.0 12.8 95. 674. 93. 15. 14 9.9 1.3 12.4 94. 711. 92. 11. 13 12.0 1.3 12.6 73. 750. 92. 7. 12 13.8 0.0 14.1 65. 791. 100. 5. 11 15.8 0.5 11.0 59. 823. 97. 2. 10 17.3 1.7 5.8 41. 845. 90. -0. 9 18.7 3.2 1.5 42. 867. 81. -2. 8 20.2 3.9 2.9 278. 890. 78. -2. 7 21.7 3.8 9.5 278. 914. 79. -2. 6 22.9 3.7 13.0 283. 939. 79. -3. 5 23.4 3.2 13.8 289. 960. 82. -3. 4 23.6 2.4 14.8 298. 976. 87. -3. 3 23.4 1.0 13.2 293. 990. 94. -2. 2 24.3 1.5 11.9 289. 1000. 92. -1. 1 25.0 1.9 10.9 288. 1006. 89. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408221600 787935 **************************************************** PBO 2408221600 FORECAST PROJECTION=34 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.8 5.2 19.4 202. 104. 42. 1. 43 -77.9 4.7 10.5 177. 112. 46. 4. 42 -76.7 4.7 13.9 56. 120. 47. 6. 41 -73.4 4.7 23.2 50. 129. 48. 9. 40 -69.2 4.7 26.9 56. 139. 50. 11. 39 -65.3 7.6 22.3 60. 150. 34. 13. 38 -62.7 8.2 13.8 48. 161. 32. 14. 37 -59.9 8.1 10.7 39. 173. 34. 13. 36 -56.9 7.4 8.6 20. 186. 39. 11. 35 -53.3 7.1 9.4 4. 199. 42. 9. 34 -49.3 7.9 8.5 356. 214. 39. 8. 33 -45.2 7.5 8.4 335. 229. 42. 6. 32 -41.3 7.5 7.8 329. 244. 44. 3. 31 -37.4 8.6 7.0 8. 261. 40. 1. 30 -33.3 11.0 8.4 57. 279. 32. -0. 29 -29.7 9.5 14.4 93. 297. 39. -2. 28 -26.8 5.8 18.2 93. 316. 58. -4. 27 -23.8 4.2 16.1 83. 337. 68. -5. 26 -20.7 3.7 12.1 65. 358. 72. -6. 25 -17.8 3.3 6.3 55. 380. 75. -6. 24 -15.3 4.1 3.6 136. 404. 71. -6. 23 -11.8 5.6 9.5 123. 429. 63. -5. 22 -8.4 5.0 14.2 105. 454. 67. -4. 21 -5.7 3.7 18.0 101. 482. 75. -3. 20 -3.3 4.4 19.2 99. 510. 71. -2. 19 -1.1 5.5 17.8 96. 540. 66. -2. 18 1.1 5.4 15.0 95. 571. 67. -3. 17 3.2 4.0 12.3 94. 603. 75. -2. 16 5.4 2.4 10.2 90. 638. 85. -2. 15 7.6 1.4 9.7 90. 673. 91. -3. 14 10.0 1.3 11.0 87. 711. 92. -3. 13 12.3 1.0 11.4 78. 750. 94. 2. 12 14.1 0.1 10.6 70. 790. 99. 10. 11 15.5 0.2 6.4 43. 823. 99. 17. 10 16.9 1.7 2.6 337. 845. 90. 19. 9 18.6 3.0 3.3 286. 867. 83. 19. 8 20.2 3.5 5.6 286. 889. 80. 16. 7 21.5 3.3 8.1 300. 914. 81. 12. 6 22.4 3.0 10.2 313. 939. 83. 9. 5 23.1 2.9 12.2 318. 959. 84. 6. 4 23.7 2.9 11.6 323. 976. 84. 3. 3 24.7 3.0 8.1 332. 989. 83. 2. 2 25.7 3.7 7.5 333. 1000. 80. 1. 1 26.4 4.1 6.7 333. 1005. 78. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408221700 787935 **************************************************** PBO 2408221700 FORECAST PROJECTION=35 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.7 6.7 10.5 157. 104. 33. 0. 43 -75.2 8.3 9.7 107. 112. 27. 1. 42 -72.8 10.0 12.1 87. 120. 21. 0. 41 -70.4 11.2 12.1 65. 129. 18. -2. 40 -68.3 9.4 13.0 59. 139. 25. -4. 39 -66.2 6.9 14.5 67. 150. 37. -7. 38 -63.4 5.7 11.8 69. 161. 46. -8. 37 -60.3 6.1 6.6 54. 173. 45. -6. 36 -56.8 8.0 6.3 21. 186. 35. -2. 35 -53.2 8.9 9.0 12. 199. 33. 2. 34 -49.4 8.1 9.4 1. 213. 38. 5. 33 -45.3 6.8 7.9 351. 229. 46. 5. 32 -41.4 7.0 6.9 4. 244. 47. 5. 31 -37.5 8.2 7.6 46. 261. 42. 5. 30 -33.8 8.0 9.7 81. 278. 44. 5. 29 -30.3 6.7 14.1 94. 297. 52. 7. 28 -27.2 5.2 15.7 90. 316. 61. 8. 27 -24.1 4.7 15.4 81. 337. 65. 6. 26 -20.9 4.3 14.2 73. 358. 68. 2. 25 -17.7 4.5 7.5 67. 380. 68. -3. 24 -14.6 5.3 2.1 114. 404. 64. -6. 23 -11.4 6.0 5.5 129. 428. 61. -6. 22 -8.3 5.2 10.7 109. 454. 66. -5. 21 -6.2 3.3 15.7 104. 481. 77. -3. 20 -4.4 2.4 18.2 96. 510. 84. 0. 19 -2.2 2.9 18.9 88. 540. 80. 4. 18 0.5 4.2 17.7 84. 571. 73. 5. 17 3.4 5.2 15.7 84. 603. 69. 4. 16 6.1 5.5 14.1 88. 637. 68. 0. 15 8.7 5.2 13.4 92. 673. 70. -4. 14 11.0 4.0 12.9 92. 710. 76. -7. 13 12.8 1.8 13.0 90. 749. 89. -9. 12 14.4 0.5 11.3 91. 790. 97. -11. 11 15.4 0.0 2.9 107. 822. 100. -10. 10 16.9 1.7 3.7 232. 844. 89. -10. 9 18.8 3.4 5.1 241. 867. 81. -9. 8 20.4 4.0 5.2 269. 889. 78. -7. 7 21.7 4.0 6.9 311. 913. 78. -6. 6 22.7 3.9 9.0 329. 938. 79. -7. 5 23.6 3.8 10.4 340. 959. 79. -9. 4 24.3 3.2 12.6 359. 975. 82. -9. 3 25.5 4.1 12.8 2. 989. 78. -7. 2 26.6 4.8 12.6 4. 999. 75. -2. 1 27.3 5.4 11.8 6. 1005. 73. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408221800 787935 **************************************************** PBO 2408221800 FORECAST PROJECTION=36 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.7 6.4 18.1 119. 104. 35. 1. 43 -74.6 9.4 17.8 100. 112. 22. 3. 42 -72.3 10.5 19.8 77. 120. 19. 4. 41 -70.8 9.7 17.7 67. 129. 23. 4. 40 -69.3 7.5 14.1 74. 139. 33. 1. 39 -66.9 6.0 13.1 89. 149. 42. -2. 38 -63.7 5.6 11.1 92. 161. 46. -5. 37 -60.3 5.4 8.5 63. 173. 49. -6. 36 -57.0 4.7 9.2 25. 186. 55. -4. 35 -53.2 6.9 9.2 22. 199. 43. -0. 34 -49.1 9.3 8.6 24. 213. 33. 3. 33 -45.1 11.0 8.0 9. 228. 28. 5. 32 -41.0 11.3 7.5 357. 244. 29. 6. 31 -37.3 10.2 6.4 18. 261. 34. 7. 30 -33.7 8.5 6.1 56. 278. 42. 9. 29 -30.4 7.0 10.7 89. 297. 50. 14. 28 -27.0 6.7 16.1 91. 316. 53. 19. 27 -23.7 6.0 17.6 90. 336. 58. 21. 26 -20.7 4.7 16.1 90. 358. 66. 21. 25 -17.6 4.8 12.5 94. 380. 66. 18. 24 -14.3 6.3 7.5 108. 403. 59. 14. 23 -10.9 7.6 7.6 118. 428. 53. 7. 22 -7.9 6.4 12.6 104. 454. 60. -0. 21 -5.6 4.4 18.5 104. 481. 71. -7. 20 -3.4 3.7 19.6 98. 509. 75. -10. 19 -1.1 3.4 18.5 88. 539. 77. -11. 18 1.2 4.1 17.0 83. 570. 74. -11. 17 3.6 5.0 15.4 84. 603. 70. -12. 16 5.8 4.9 13.8 87. 637. 71. -14. 15 8.0 3.9 12.1 92. 672. 76. -17. 14 10.0 2.4 9.9 101. 709. 85. -18. 13 12.1 0.7 7.0 93. 748. 96. -16. 12 14.6 0.0 6.9 63. 789. 100. -13. 11 16.0 0.0 3.0 59. 821. 100. -14. 10 17.9 2.4 3.2 256. 844. 86. -16. 9 19.6 4.5 6.3 261. 866. 75. -17. 8 21.0 5.3 6.9 278. 888. 72. -14. 7 22.4 5.6 7.5 305. 912. 71. -10. 6 24.0 6.3 9.3 322. 937. 68. -6. 5 25.2 6.7 10.0 329. 958. 66. -3. 4 25.9 6.8 10.0 341. 974. 66. -1. 3 26.0 6.5 11.6 352. 987. 68. 1. 2 25.5 3.9 10.6 5. 998. 79. 2. 1 26.2 4.3 9.5 6. 1004. 77. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1006. **************************************************** STATION = 9.35N 82.25W PBO 2408221900 787935 **************************************************** PBO 2408221900 FORECAST PROJECTION=37 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -75.6 9.2 27.8 106. 104. 23. -1. 43 -73.9 9.4 13.0 95. 112. 23. -4. 42 -72.9 8.2 7.1 95. 120. 28. -4. 41 -72.5 5.1 6.0 54. 129. 46. -3. 40 -70.7 4.7 8.1 33. 139. 50. 0. 39 -67.7 5.3 9.2 24. 149. 47. 4. 38 -64.3 6.3 10.2 23. 161. 41. 7. 37 -60.2 8.6 14.2 16. 173. 31. 6. 36 -56.0 11.0 17.9 20. 186. 24. 1. 35 -52.4 9.9 17.3 21. 199. 29. -6. 34 -48.8 9.1 12.6 21. 213. 34. -13. 33 -44.9 10.6 8.0 30. 228. 29. -17. 32 -41.0 12.1 5.7 31. 244. 26. -20. 31 -37.3 10.9 5.7 44. 261. 31. -21. 30 -33.7 9.4 7.4 78. 278. 38. -20. 29 -30.1 9.4 9.7 95. 297. 39. -17. 28 -26.5 9.0 10.3 96. 316. 42. -13. 27 -23.4 7.7 8.2 85. 336. 49. -10. 26 -20.5 6.5 5.8 76. 358. 56. -8. 25 -17.6 5.6 5.2 100. 380. 62. -9. 24 -14.7 5.0 5.6 136. 403. 66. -10. 23 -12.1 3.3 10.1 133. 428. 76. -10. 22 -9.6 2.1 15.3 123. 454. 84. -10. 21 -7.0 2.5 17.4 112. 481. 83. -7. 20 -4.4 3.4 17.6 99. 509. 77. -2. 19 -1.9 4.2 17.6 91. 539. 73. 4. 18 0.7 4.7 16.7 89. 570. 71. 9. 17 3.1 4.7 15.1 88. 603. 71. 12. 16 5.4 4.0 13.1 85. 637. 76. 12. 15 7.6 2.9 11.6 80. 672. 82. 8. 14 10.0 2.4 10.9 76. 710. 85. 1. 13 12.7 2.2 10.4 74. 749. 86. -6. 12 15.1 1.8 9.7 71. 789. 89. -7. 11 17.0 1.9 6.2 51. 821. 89. -2. 10 18.3 2.7 2.4 1. 843. 84. 0. 9 19.9 4.5 2.7 297. 866. 76. -0. 8 21.3 5.6 3.7 308. 888. 71. -2. 7 22.6 5.9 3.6 351. 912. 69. -4. 6 24.0 6.6 5.1 29. 937. 67. -6. 5 25.0 6.9 7.2 25. 958. 65. -6. 4 25.5 6.4 9.4 14. 974. 68. -4. 3 25.9 3.6 10.1 19. 987. 80. -3. 2 27.0 4.4 10.0 21. 998. 77. -1. 1 27.8 4.9 9.5 22. 1004. 75. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1006. **************************************************** STATION = 9.35N 82.25W PBO 2408222000 787935 **************************************************** PBO 2408222000 FORECAST PROJECTION=38 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.5 8.5 29.8 102. 104. 25. -0. 43 -75.0 8.8 11.7 74. 112. 24. -2. 42 -73.9 6.9 7.4 42. 120. 34. -5. 41 -71.8 6.7 5.7 32. 129. 36. -8. 40 -69.6 5.9 4.9 55. 139. 42. -10. 39 -67.0 5.3 8.0 66. 149. 47. -11. 38 -63.8 6.0 14.3 56. 161. 44. -12. 37 -60.3 7.6 18.6 47. 173. 36. -11. 36 -56.8 8.5 19.0 35. 185. 33. -9. 35 -53.0 9.0 17.2 27. 199. 32. -8. 34 -48.9 7.5 14.0 23. 213. 41. -5. 33 -45.0 6.4 11.2 40. 228. 49. -2. 32 -41.1 9.5 8.7 55. 244. 35. 1. 31 -37.4 10.4 7.2 77. 261. 33. 5. 30 -33.7 9.2 8.6 110. 278. 39. 9. 29 -29.9 9.5 11.2 120. 296. 39. 13. 28 -26.3 9.6 10.8 119. 316. 40. 15. 27 -23.2 8.6 6.8 111. 336. 45. 16. 26 -20.3 7.6 3.8 98. 357. 51. 15. 25 -17.4 6.5 4.6 121. 380. 57. 12. 24 -14.4 6.1 5.1 137. 403. 60. 8. 23 -11.5 5.1 8.0 123. 428. 66. 7. 22 -8.7 4.6 13.2 110. 453. 70. 5. 21 -6.1 4.7 15.8 101. 480. 69. 3. 20 -3.3 5.7 16.8 92. 509. 64. 0. 19 -0.5 6.9 17.3 88. 538. 59. -3. 18 2.0 7.5 16.3 88. 569. 58. -6. 17 4.2 7.1 14.3 87. 602. 60. -8. 16 6.2 6.0 12.4 82. 636. 65. -11. 15 8.2 4.5 10.3 76. 671. 73. -14. 14 10.0 2.7 8.2 70. 709. 83. -18. 13 12.2 1.6 7.0 62. 748. 90. -21. 12 14.6 1.3 6.1 47. 788. 92. -22. 11 16.4 1.4 5.0 12. 820. 92. -21. 10 18.0 2.7 5.4 333. 842. 84. -19. 9 19.4 3.9 6.4 325. 865. 78. -19. 8 20.6 4.3 5.1 350. 887. 76. -20. 7 22.2 4.7 5.8 32. 911. 75. -21. 6 23.6 5.1 8.1 43. 936. 73. -19. 5 24.7 5.8 7.9 25. 956. 70. -14. 4 25.3 5.1 8.6 353. 973. 73. -11. 3 26.3 4.1 9.0 345. 986. 78. -7. 2 27.3 4.7 8.5 345. 997. 76. -3. 1 28.0 5.1 7.9 345. 1003. 74. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1005. **************************************************** STATION = 9.35N 82.25W PBO 2408222100 787935 **************************************************** PBO 2408222100 FORECAST PROJECTION=39 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.3 8.0 38.8 95. 104. 27. -1. 43 -75.7 8.1 23.1 99. 112. 27. -3. 42 -75.2 4.8 11.3 89. 120. 47. -2. 41 -73.6 4.8 2.6 33. 129. 48. 1. 40 -70.5 4.7 1.6 51. 139. 50. 6. 39 -67.5 5.0 6.6 104. 149. 49. 9. 38 -64.0 6.2 10.9 99. 161. 42. 9. 37 -60.2 9.3 12.8 89. 173. 28. 9. 36 -56.2 12.9 13.0 82. 186. 18. 8. 35 -52.2 15.1 12.4 85. 199. 15. 8. 34 -48.4 16.4 10.5 84. 213. 13. 7. 33 -44.9 9.9 7.4 77. 228. 32. 6. 32 -41.4 7.9 6.3 91. 244. 42. 6. 31 -37.7 7.4 7.3 117. 261. 46. 8. 30 -33.8 7.3 9.2 132. 278. 48. 10. 29 -29.9 8.3 9.4 131. 296. 44. 12. 28 -26.3 9.2 6.7 107. 316. 42. 14. 27 -23.0 9.3 5.5 44. 336. 42. 15. 26 -20.0 8.8 7.3 23. 357. 45. 12. 25 -17.3 7.0 7.4 39. 380. 55. 8. 24 -14.5 5.6 8.4 62. 403. 62. 3. 23 -11.5 5.3 11.3 79. 428. 65. -1. 22 -8.6 5.9 14.1 87. 454. 63. -3. 21 -6.1 5.7 14.8 84. 481. 64. -4. 20 -3.6 5.6 15.4 85. 509. 65. -3. 19 -1.2 5.7 16.0 87. 539. 65. -2. 18 1.1 6.0 16.1 84. 570. 64. -2. 17 3.6 6.1 15.5 79. 602. 65. -3. 16 6.0 5.6 13.9 75. 636. 67. -3. 15 8.1 4.4 11.3 74. 672. 74. -2. 14 10.0 2.7 7.6 79. 709. 83. -1. 13 11.9 1.2 4.3 88. 748. 92. 2. 12 14.3 0.8 1.8 65. 789. 95. 5. 11 16.1 1.0 2.7 340. 820. 94. 7. 10 16.9 0.6 4.4 342. 843. 96. 6. 9 18.0 0.9 6.2 3. 865. 95. 3. 8 19.5 2.1 8.7 357. 887. 88. 2. 7 21.4 3.9 10.1 354. 912. 78. 1. 6 23.2 5.4 11.0 354. 936. 72. 1. 5 24.4 5.8 11.9 351. 957. 70. 0. 4 24.9 4.4 13.3 344. 973. 76. 1. 3 25.5 2.6 13.1 336. 987. 85. 1. 2 26.5 3.5 12.6 336. 997. 81. 2. 1 27.3 4.0 11.4 336. 1003. 79. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1005. **************************************************** STATION = 9.35N 82.25W PBO 2408222200 787935 **************************************************** PBO 2408222200 FORECAST PROJECTION=40 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.3 7.8 33.0 92. 104. 28. -1. 43 -75.7 8.5 24.2 102. 112. 26. -3. 42 -74.4 6.8 16.5 110. 120. 34. -4. 41 -72.8 5.6 8.7 115. 129. 42. -5. 40 -70.8 4.7 9.0 120. 139. 50. -7. 39 -68.0 4.7 12.6 117. 149. 51. -8. 38 -64.4 6.4 13.7 111. 161. 41. -9. 37 -60.5 9.1 12.3 107. 173. 29. -9. 36 -56.6 11.5 9.6 101. 186. 22. -7. 35 -52.8 11.1 6.9 85. 199. 25. -4. 34 -48.9 10.2 6.5 45. 213. 30. -1. 33 -45.0 10.1 8.2 29. 228. 31. 3. 32 -41.1 10.0 7.7 39. 244. 33. 5. 31 -37.4 9.4 6.1 72. 261. 37. 7. 30 -33.5 9.0 5.2 104. 278. 40. 8. 29 -29.7 9.3 4.7 107. 296. 40. 8. 28 -26.1 10.1 3.8 38. 316. 38. 7. 27 -22.9 9.3 8.0 347. 336. 42. 6. 26 -20.0 7.1 10.6 348. 357. 53. 4. 25 -17.3 6.4 8.7 7. 380. 57. 4. 24 -14.4 6.0 8.3 43. 403. 60. 3. 23 -11.4 6.5 9.4 72. 428. 58. 1. 22 -8.7 6.5 11.8 81. 453. 60. -1. 21 -6.1 6.3 14.0 83. 480. 61. -3. 20 -3.4 6.2 15.5 88. 509. 62. -5. 19 -1.0 6.2 16.6 88. 538. 63. -8. 18 1.4 6.0 17.0 85. 569. 64. -12. 17 3.7 5.9 16.4 81. 602. 65. -13. 16 6.1 5.8 15.2 76. 636. 66. -12. 15 8.4 5.0 13.0 73. 671. 71. -7. 14 10.4 3.6 10.3 67. 709. 78. -4. 13 12.5 2.6 8.5 55. 748. 84. -4. 12 15.0 2.4 7.4 43. 788. 85. -6. 11 17.3 3.2 6.9 34. 820. 82. -8. 10 18.5 2.9 6.6 18. 842. 83. -7. 9 19.4 2.7 6.5 357. 865. 84. -4. 8 20.5 2.8 6.3 332. 887. 84. 1. 7 21.5 2.8 6.9 324. 911. 84. 5. 6 22.1 2.1 8.3 325. 936. 88. 5. 5 22.9 0.6 10.4 326. 957. 96. 1. 4 24.1 0.9 11.8 331. 973. 94. -2. 3 25.3 1.9 11.7 332. 987. 89. -1. 2 26.3 2.6 11.4 333. 997. 85. 0. 1 26.9 3.1 10.5 333. 1003. 83. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1005. **************************************************** STATION = 9.35N 82.25W PBO 2408222300 787935 **************************************************** PBO 2408222300 FORECAST PROJECTION=41 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.8 6.6 14.3 84. 104. 34. -1. 43 -75.5 8.1 16.2 103. 112. 27. -6. 42 -73.6 8.6 15.7 103. 120. 26. -12. 41 -72.3 6.8 17.3 90. 129. 35. -18. 40 -70.4 5.2 22.7 85. 139. 46. -22. 39 -67.1 6.4 25.3 86. 149. 40. -23. 38 -63.3 9.7 20.5 81. 161. 26. -24. 37 -60.0 10.8 14.4 83. 173. 23. -25. 36 -56.4 11.0 11.2 94. 186. 24. -26. 35 -52.6 10.4 8.1 86. 199. 27. -26. 34 -48.9 8.8 5.1 39. 213. 35. -26. 33 -45.0 6.9 6.8 359. 228. 46. -24. 32 -41.2 7.0 6.3 344. 244. 46. -21. 31 -37.3 9.1 1.9 320. 261. 38. -17. 30 -33.4 10.2 2.9 205. 278. 35. -17. 29 -29.7 9.6 2.8 238. 297. 39. -20. 28 -26.5 6.7 5.0 313. 316. 53. -23. 27 -23.6 3.7 8.0 342. 336. 71. -23. 26 -20.7 3.7 7.1 16. 358. 72. -17. 25 -17.9 4.4 7.0 62. 380. 68. -8. 24 -14.9 5.0 10.6 89. 404. 66. 2. 23 -12.0 5.7 15.1 95. 428. 63. 12. 22 -9.0 6.4 18.9 94. 454. 60. 21. 21 -5.9 7.1 20.9 91. 481. 57. 27. 20 -3.0 7.5 21.4 90. 509. 56. 29. 19 -0.4 7.2 20.6 87. 539. 58. 27. 18 1.8 6.1 17.9 86. 570. 64. 22. 17 3.5 4.6 14.2 84. 603. 72. 15. 16 5.3 3.6 11.4 80. 637. 78. 6. 15 7.1 2.2 9.4 67. 672. 86. -2. 14 9.2 1.1 8.4 48. 710. 93. -11. 13 11.6 1.1 7.3 34. 749. 93. -19. 12 14.0 1.0 6.9 17. 790. 94. -27. 11 15.6 0.1 7.6 359. 822. 100. -33. 10 16.9 0.1 8.9 349. 844. 100. -36. 9 18.0 0.2 10.8 341. 866. 98. -36. 8 19.4 1.2 12.5 335. 888. 93. -33. 7 21.0 2.5 13.4 329. 913. 86. -26. 6 22.4 3.3 13.8 321. 938. 82. -18. 5 23.5 3.5 14.6 318. 958. 81. -10. 4 24.3 3.2 14.9 320. 975. 83. -5. 3 25.1 2.4 14.3 319. 988. 87. -1. 2 26.0 3.1 13.4 319. 999. 83. 1. 1 26.5 3.4 11.0 319. 1004. 82. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408230000 787935 **************************************************** PBO 2408230000 FORECAST PROJECTION=42 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.5 6.4 22.2 115. 104. 36. -1. 43 -78.1 4.7 13.3 115. 112. 47. -2. 42 -77.5 4.6 18.4 94. 120. 47. -3. 41 -74.7 4.7 22.3 91. 129. 48. -4. 40 -71.4 4.7 20.0 83. 139. 49. -3. 39 -67.8 4.7 15.2 76. 149. 51. -1. 38 -64.1 5.4 11.5 77. 161. 48. 1. 37 -60.4 9.9 9.7 85. 173. 26. 2. 36 -56.6 10.3 8.9 94. 186. 26. 4. 35 -52.7 10.4 8.1 83. 199. 27. 7. 34 -48.7 10.2 6.9 59. 213. 30. 9. 33 -44.8 10.1 6.2 26. 228. 31. 12. 32 -40.9 9.7 4.6 12. 244. 34. 15. 31 -37.1 10.3 2.3 65. 261. 34. 18. 30 -33.3 11.1 3.6 129. 278. 32. 20. 29 -29.6 10.2 3.4 152. 297. 37. 21. 28 -26.2 8.3 1.2 29. 316. 46. 21. 27 -22.7 7.5 5.7 12. 336. 50. 19. 26 -19.5 7.1 7.3 35. 358. 53. 16. 25 -16.7 7.3 7.8 74. 380. 53. 13. 24 -13.8 7.8 9.8 100. 404. 52. 9. 23 -11.0 8.7 11.3 95. 428. 49. 6. 22 -8.3 9.3 12.5 76. 454. 47. 3. 21 -6.0 7.8 14.6 68. 481. 54. 0. 20 -4.1 5.1 16.6 70. 510. 67. -3. 19 -2.1 3.1 17.5 75. 539. 79. -6. 18 0.1 2.3 17.0 78. 570. 84. -7. 17 2.5 2.3 16.1 78. 603. 85. -7. 16 4.9 2.4 15.0 75. 637. 85. -3. 15 7.3 2.2 13.0 72. 673. 86. 2. 14 9.5 1.7 10.5 71. 710. 89. 8. 13 11.9 1.8 7.8 61. 749. 89. 15. 12 14.2 1.6 5.9 24. 790. 90. 19. 11 15.5 0.4 6.4 356. 822. 97. 20. 10 16.6 0.1 8.0 344. 844. 100. 17. 9 17.9 0.4 9.5 341. 866. 98. 13. 8 19.2 0.8 9.8 346. 889. 95. 11. 7 20.8 1.5 9.7 350. 913. 91. 11. 6 22.4 2.4 10.1 343. 938. 86. 12. 5 23.5 2.8 12.2 327. 959. 84. 12. 4 24.1 2.0 16.1 315. 975. 89. 10. 3 24.9 1.6 15.7 312. 989. 91. 8. 2 25.8 2.2 14.2 313. 999. 88. 5. 1 26.2 2.4 10.6 314. 1005. 87. 3. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408230100 787935 **************************************************** PBO 2408230100 FORECAST PROJECTION=43 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.9 4.9 37.1 123. 104. 46. -0. 43 -78.8 4.6 19.1 128. 112. 47. -2. 42 -78.1 4.6 16.6 104. 120. 47. -3. 41 -75.6 4.7 15.2 86. 129. 48. -3. 40 -72.3 4.7 11.9 74. 139. 49. -4. 39 -68.6 4.7 9.4 77. 150. 51. -4. 38 -64.8 4.7 7.8 98. 161. 52. -4. 37 -60.9 6.2 7.1 107. 173. 44. -3. 36 -56.9 8.3 6.4 88. 186. 34. -1. 35 -52.9 8.8 6.4 56. 199. 34. 2. 34 -48.9 9.3 5.9 33. 213. 33. 3. 33 -45.1 8.3 3.8 26. 228. 39. 3. 32 -41.4 7.5 1.7 69. 244. 44. 3. 31 -37.7 7.7 2.8 119. 261. 44. 3. 30 -34.1 6.9 1.8 136. 278. 50. 3. 29 -30.5 5.5 1.3 329. 297. 58. 2. 28 -26.8 5.2 4.1 344. 316. 62. 2. 27 -23.3 5.4 5.1 13. 337. 61. 4. 26 -20.3 5.6 5.0 54. 358. 61. 6. 25 -17.3 6.3 6.5 92. 380. 58. 7. 24 -14.3 7.7 9.5 102. 404. 52. 5. 23 -11.3 9.2 11.8 101. 428. 46. 2. 22 -8.8 4.3 15.3 89. 454. 71. 0. 21 -6.5 1.8 17.7 77. 481. 87. -1. 20 -4.1 2.5 20.5 80. 510. 83. -2. 19 -1.3 3.5 21.7 78. 540. 77. -4. 18 1.6 3.9 21.3 77. 571. 75. -7. 17 3.4 2.4 19.2 77. 603. 84. -9. 16 5.3 1.8 14.1 63. 637. 88. -11. 15 7.0 1.0 14.6 41. 673. 93. -6. 14 9.7 1.2 18.7 14. 710. 92. 4. 13 11.7 0.7 11.7 6. 749. 95. 4. 12 13.6 0.0 3.7 22. 790. 100. -7. 11 15.5 0.5 6.7 319. 822. 97. -11. 10 17.1 1.3 8.1 322. 845. 92. -8. 9 18.4 1.5 7.7 322. 867. 91. -7. 8 19.5 1.3 6.4 318. 889. 92. -9. 7 20.5 1.0 7.2 314. 914. 94. -13. 6 21.4 0.7 13.6 317. 938. 96. -17. 5 22.4 0.5 18.4 321. 959. 97. -18. 4 23.7 0.7 16.9 319. 976. 96. -18. 3 24.7 1.2 14.6 320. 989. 93. -13. 2 25.5 1.7 11.9 320. 1000. 90. -7. 1 26.0 1.9 8.7 321. 1005. 89. -1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408230200 787935 **************************************************** PBO 2408230200 FORECAST PROJECTION=44 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.2 4.7 33.3 124. 104. 47. 1. 43 -80.2 4.6 30.4 103. 112. 47. 4. 42 -79.0 4.8 36.0 94. 120. 46. 5. 41 -75.9 4.7 29.5 94. 129. 48. 3. 40 -72.4 4.7 16.4 94. 139. 49. 2. 39 -68.7 4.7 9.3 83. 150. 51. 3. 38 -65.1 4.7 7.2 80. 161. 52. 4. 37 -61.3 4.6 5.9 69. 173. 54. 2. 36 -57.3 4.5 6.8 28. 186. 56. -2. 35 -53.1 4.4 12.1 4. 199. 59. -7. 34 -49.0 4.2 10.3 359. 214. 61. -9. 33 -45.2 4.9 2.1 336. 229. 58. -11. 32 -41.3 8.5 2.9 239. 244. 39. -12. 31 -37.4 9.8 4.2 207. 261. 35. -13. 30 -33.6 10.1 4.9 202. 278. 35. -13. 29 -29.9 9.0 4.2 214. 297. 41. -12. 28 -26.5 7.0 2.3 242. 316. 52. -10. 27 -23.5 5.0 1.7 72. 337. 63. -5. 26 -20.7 4.7 6.7 79. 358. 66. 2. 25 -17.7 4.6 9.3 86. 380. 67. 6. 24 -14.6 2.4 11.5 87. 404. 82. 5. 23 -11.7 0.9 16.4 82. 429. 93. 5. 22 -9.2 2.8 19.5 75. 454. 80. 10. 21 -6.1 6.8 23.5 77. 482. 59. 15. 20 -3.1 7.2 26.4 80. 510. 57. 14. 19 -0.1 5.8 25.5 83. 540. 65. 11. 18 0.6 0.7 19.2 75. 571. 95. -1. 17 2.7 0.0 18.2 60. 603. 100. -21. 16 5.1 0.0 16.9 50. 638. 100. -26. 15 7.5 0.0 13.9 35. 673. 100. -16. 14 9.7 0.0 13.8 30. 711. 100. -10. 13 11.9 0.0 14.6 30. 750. 100. -8. 12 14.2 0.2 13.1 25. 791. 99. -3. 11 16.7 1.9 8.5 356. 823. 88. -1. 10 17.3 2.5 7.4 323. 845. 85. -6. 9 18.1 1.8 9.6 310. 867. 89. -11. 8 19.3 1.4 10.8 311. 890. 92. -12. 7 20.8 1.8 12.7 312. 914. 90. -10. 6 22.3 2.1 13.9 312. 939. 88. -8. 5 23.1 1.5 14.6 307. 960. 91. -5. 4 23.8 0.7 14.2 307. 976. 96. -3. 3 24.5 1.3 14.1 318. 989. 93. -0. 2 24.6 1.5 12.4 334. 1000. 91. 2. 1 24.9 1.5 8.9 334. 1006. 91. 2. PRCP(HR)=.002 PRCP(TOT)= 0.002 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408230300 787935 **************************************************** PBO 2408230300 FORECAST PROJECTION=45 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.4 6.3 48.9 92. 104. 37. -2. 43 -77.8 4.7 30.6 83. 112. 47. -5. 42 -77.7 4.8 29.1 68. 120. 46. -8. 41 -75.8 4.7 25.2 67. 129. 48. -8. 40 -72.7 4.7 20.7 76. 139. 49. -5. 39 -68.9 4.8 14.4 83. 150. 49. 0. 38 -65.0 5.0 9.2 95. 161. 50. 6. 37 -61.2 5.1 6.0 81. 173. 51. 10. 36 -57.3 5.6 4.1 36. 186. 49. 11. 35 -53.4 5.4 3.7 21. 199. 51. 7. 34 -49.4 4.3 3.5 17. 214. 61. 1. 33 -45.3 4.1 3.8 336. 229. 63. -5. 32 -41.3 4.8 1.7 279. 244. 60. -8. 31 -37.3 9.0 2.8 173. 261. 38. -8. 30 -33.4 10.8 3.9 149. 279. 33. -9. 29 -29.7 10.4 4.2 122. 297. 36. -9. 28 -26.1 8.5 5.4 104. 316. 45. -7. 27 -22.8 6.6 10.9 111. 337. 55. -5. 26 -19.7 6.5 14.8 117. 358. 56. -3. 25 -16.8 8.0 14.9 109. 380. 50. -3. 24 -14.1 6.4 15.8 100. 404. 58. -4. 23 -11.6 3.4 18.0 96. 429. 76. -2. 22 -8.8 1.8 18.6 92. 454. 87. 1. 21 -6.2 0.5 17.7 84. 482. 96. 2. 20 -3.9 0.5 17.6 66. 510. 96. -0. 19 -1.5 1.2 16.4 51. 540. 91. -0. 18 0.5 0.4 15.2 45. 571. 97. 6. 17 3.1 0.3 14.0 38. 604. 98. 15. 16 5.6 0.5 12.9 30. 638. 97. 24. 15 7.9 1.0 18.0 7. 674. 94. 29. 14 10.0 0.8 22.1 357. 711. 95. 23. 13 11.7 0.0 20.5 358. 750. 100. 2. 12 14.0 0.0 15.0 2. 791. 100. -21. 11 15.5 0.0 9.3 354. 823. 100. -30. 10 16.7 0.0 6.8 331. 845. 100. -25. 9 17.9 0.0 7.1 314. 867. 100. -16. 8 19.0 0.1 8.5 310. 890. 99. -6. 7 20.3 0.5 10.8 307. 914. 97. 7. 6 21.6 0.6 13.2 315. 939. 97. 19. 5 22.5 0.6 14.8 328. 960. 96. 25. 4 23.3 0.7 16.6 336. 976. 96. 24. 3 23.9 0.8 18.0 341. 990. 95. 20. 2 24.3 0.9 16.6 340. 1000. 95. 13. 1 24.8 1.1 13.6 338. 1006. 94. 6. PRCP(HR)=.006 PRCP(TOT)= 0.006 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408230400 787935 **************************************************** PBO 2408230400 FORECAST PROJECTION=46 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -79.5 4.6 39.7 76. 104. 47. 1. 43 -82.1 4.8 27.8 54. 112. 44. 1. 42 -79.4 4.6 30.3 42. 120. 47. 1. 41 -75.3 4.7 32.5 43. 129. 48. -1. 40 -71.5 4.7 31.9 47. 139. 49. -10. 39 -67.6 4.7 29.8 55. 150. 51. -22. 38 -63.8 5.4 27.4 65. 161. 48. -35. 37 -60.3 8.1 21.7 80. 173. 34. -47. 36 -56.8 5.9 14.8 105. 186. 47. -55. 35 -52.9 4.4 11.2 127. 199. 59. -58. 34 -48.9 4.2 9.2 147. 214. 61. -59. 33 -44.9 4.1 10.4 146. 229. 64. -55. 32 -41.1 3.9 17.2 127. 244. 66. -48. 31 -37.4 3.7 23.6 121. 261. 69. -49. 30 -33.4 3.4 19.8 119. 279. 71. -62. 29 -30.2 0.1 15.2 113. 297. 99. -79. 28 -26.4 0.0 15.1 111. 316. 100. -87. 27 -22.8 -0.0 15.9 105. 337. 100. -86. 26 -19.7 -0.0 16.8 94. 358. 100. -80. 25 -16.8 -0.0 17.2 81. 381. 100. -71. 24 -14.1 -0.0 17.2 67. 404. 100. -58. 23 -11.6 -0.0 18.3 57. 429. 100. -41. 22 -9.2 -0.0 21.1 55. 455. 100. -19. 21 -6.7 0.1 25.5 58. 482. 99. 9. 20 -4.2 0.6 29.6 61. 510. 96. 33. 19 -1.7 0.8 29.3 61. 540. 94. 46. 18 0.5 0.8 24.6 56. 571. 94. 52. 17 1.5 0.0 19.0 50. 604. 100. 55. 16 4.3 0.4 14.4 43. 638. 98. 57. 15 7.6 1.6 12.7 27. 674. 90. 52. 14 10.2 1.6 11.3 12. 711. 90. 39. 13 11.9 0.6 10.8 352. 750. 96. 21. 12 14.4 1.1 10.9 325. 791. 93. 4. 11 16.7 2.3 13.0 316. 823. 86. -9. 10 17.7 2.2 15.5 312. 846. 87. -16. 9 18.3 1.5 17.9 305. 868. 91. -19. 8 19.2 1.1 19.3 300. 890. 93. -18. 7 20.6 1.8 20.1 302. 915. 90. -15. 6 22.0 2.3 20.8 310. 939. 87. -11. 5 23.0 1.9 21.0 318. 960. 89. -8. 4 23.7 1.9 19.7 326. 977. 89. -5. 3 24.2 2.4 16.8 337. 990. 86. -2. 2 24.9 2.7 14.1 339. 1001. 85. 0. 1 25.1 2.5 9.5 337. 1006. 86. 1. PRCP(HR)=.142 PRCP(TOT)= 0.142 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408230500 787935 **************************************************** PBO 2408230500 FORECAST PROJECTION=47 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.7 5.6 44.7 119. 104. 41. -0. 43 -78.4 4.7 30.1 107. 112. 46. -2. 42 -76.7 5.8 27.8 72. 120. 40. -5. 41 -75.4 4.7 25.9 37. 129. 48. -7. 40 -72.6 4.7 20.2 19. 139. 49. -8. 39 -68.5 4.7 6.9 22. 150. 51. -7. 38 -65.4 4.7 17.1 130. 161. 52. -10. 37 -61.6 4.6 17.9 133. 173. 54. -20. 36 -57.4 4.5 15.9 137. 186. 56. -32. 35 -53.2 4.4 14.5 141. 199. 59. -37. 34 -49.0 4.2 13.1 145. 214. 61. -35. 33 -44.9 4.1 11.8 150. 229. 64. -27. 32 -40.9 3.8 10.9 157. 244. 66. -17. 31 -37.0 3.6 11.3 163. 261. 69. -11. 30 -33.2 3.4 12.9 163. 279. 72. -12. 29 -29.5 3.1 13.3 158. 297. 74. -22. 28 -26.2 2.8 10.6 139. 316. 77. -33. 27 -23.2 2.4 8.9 94. 337. 81. -38. 26 -20.4 1.9 11.6 74. 358. 85. -35. 25 -17.8 1.4 13.4 61. 380. 89. -26. 24 -15.0 1.5 16.4 56. 404. 88. -11. 23 -11.8 2.0 22.1 59. 429. 85. 1. 22 -8.6 3.3 27.1 66. 455. 77. 6. 21 -5.7 2.9 27.7 79. 482. 80. 2. 20 -4.0 0.3 28.8 84. 510. 98. -5. 19 -2.1 0.0 24.9 77. 540. 100. -13. 18 0.0 0.0 19.3 67. 571. 100. -21. 17 2.4 0.0 17.6 65. 604. 100. -23. 16 4.8 0.0 14.6 63. 638. 100. -14. 15 7.1 0.0 10.0 51. 674. 100. -1. 14 9.9 0.8 6.7 356. 711. 95. 7. 13 12.1 0.8 5.8 313. 750. 95. 9. 12 14.2 1.0 7.8 286. 791. 94. 12. 11 16.0 1.6 11.5 286. 823. 90. 19. 10 17.0 1.6 16.4 286. 845. 90. 27. 9 17.9 1.4 18.7 289. 867. 91. 32. 8 18.7 1.2 18.3 292. 890. 93. 29. 7 19.8 0.8 17.1 299. 914. 95. 23. 6 21.2 0.3 18.3 304. 939. 98. 18. 5 22.6 0.1 18.4 307. 960. 100. 14. 4 23.1 0.1 13.8 307. 976. 100. 9. 3 23.6 0.6 8.5 300. 990. 96. 6. 2 24.0 0.8 4.6 278. 1000. 95. 3. 1 24.4 1.0 3.2 262. 1006. 94. 1. PRCP(HR)=.181 PRCP(TOT)= 0.181 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408230600 787935 **************************************************** PBO 2408230600 FORECAST PROJECTION=48 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.7 7.0 38.1 113. 104. 32. 1. 43 -75.1 8.9 41.7 112. 112. 24. 4. 42 -74.6 5.9 32.2 79. 120. 40. 9. 41 -75.4 4.7 25.1 47. 129. 48. 8. 40 -74.2 4.8 14.9 71. 139. 48. -13. 39 -70.1 4.7 13.2 68. 149. 50. -53. 38 -66.0 4.7 12.0 62. 161. 52. -96. 37 -61.7 4.6 12.6 57. 173. 54. -133. 36 -57.4 4.5 14.2 56. 186. 56. -161. 35 -53.1 4.4 16.5 57. 199. 59. -177. 34 -48.9 4.2 19.0 59. 213. 61. -183. 33 -44.7 4.1 21.3 61. 228. 64. -180. 32 -40.6 3.9 22.9 62. 244. 66. -171. 31 -37.1 -0.0 23.7 62. 261. 100. -157. 30 -33.3 -0.0 23.7 62. 278. 100. -142. 29 -29.7 0.0 23.3 61. 297. 100. -131. 28 -26.3 0.1 23.6 62. 316. 99. -125. 27 -22.6 1.0 24.9 65. 337. 91. -119. 26 -19.3 1.6 26.8 72. 358. 87. -109. 25 -16.5 1.3 29.2 81. 380. 90. -91. 24 -14.1 0.9 30.8 89. 404. 93. -62. 23 -11.2 1.6 29.6 98. 429. 88. -28. 22 -8.3 2.8 25.5 106. 455. 80. 6. 21 -5.3 3.6 21.6 117. 482. 76. 40. 20 -2.4 3.9 21.6 124. 510. 75. 74. 19 0.2 3.9 25.7 121. 540. 75. 100. 18 2.0 2.6 26.1 122. 571. 83. 100. 17 2.9 0.8 17.8 134. 604. 95. 71. 16 4.5 0.2 5.1 155. 638. 98. 31. 15 6.6 0.8 7.4 20. 673. 94. 3. 14 9.4 1.3 10.0 356. 711. 91. 2. 13 12.2 1.7 11.3 296. 750. 89. 18. 12 14.5 1.9 13.3 282. 791. 88. 31. 11 16.3 2.3 13.2 282. 823. 86. 34. 10 17.3 2.1 13.5 291. 845. 87. 31. 9 18.3 2.1 15.2 301. 867. 88. 29. 8 19.4 2.0 16.1 303. 889. 88. 26. 7 20.4 1.9 15.3 299. 914. 89. 21. 6 21.4 1.5 14.8 299. 939. 91. 13. 5 22.1 0.5 15.2 305. 959. 97. 3. 4 23.0 0.1 14.8 312. 976. 100. -4. 3 23.6 0.0 12.7 309. 989. 100. -6. 2 24.2 0.2 10.3 298. 1000. 99. -4. 1 24.6 0.5 8.5 295. 1006. 97. -1. PRCP(HR)=.299 PRCP(TOT)= 0.299 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408230700 787935 **************************************************** PBO 2408230700 FORECAST PROJECTION=49 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -75.1 8.6 21.3 106. 104. 25. 8. 43 -73.1 10.2 26.6 92. 112. 20. 27. 42 -71.1 13.5 34.3 89. 120. 12. 38. 41 -68.8 9.4 34.9 87. 129. 25. 40. 40 -69.5 4.7 34.2 68. 139. 50. 32. 39 -69.9 4.7 29.8 42. 149. 50. 16. 38 -66.2 4.7 29.7 33. 161. 52. -3. 37 -61.9 4.6 29.3 32. 173. 54. -20. 36 -57.6 4.5 28.5 30. 186. 56. -33. 35 -53.4 4.4 27.4 29. 199. 59. -39. 34 -49.2 4.2 26.8 33. 213. 61. -40. 33 -45.1 4.1 25.9 42. 228. 64. -36. 32 -41.1 3.9 24.2 54. 244. 66. -27. 31 -37.3 3.6 21.8 66. 261. 69. -18. 30 -33.7 3.4 20.0 79. 278. 71. -9. 29 -30.2 3.1 20.2 89. 297. 74. -3. 28 -26.7 3.1 20.5 96. 316. 75. 0. 27 -23.3 3.2 19.2 102. 336. 75. 2. 26 -20.1 3.0 15.8 115. 358. 77. 3. 25 -17.1 2.9 15.5 121. 380. 78. 3. 24 -14.4 2.8 17.0 119. 404. 79. 1. 23 -12.1 1.5 17.9 125. 428. 88. -4. 22 -9.4 0.4 18.2 133. 454. 97. -10. 21 -6.9 0.2 19.9 138. 481. 98. -13. 20 -4.5 0.3 22.4 139. 510. 98. -16. 19 -2.1 0.5 24.3 139. 540. 96. -20. 18 0.7 1.5 24.9 135. 571. 90. -25. 17 2.6 1.7 23.4 133. 603. 89. -27. 16 5.6 3.5 19.9 133. 637. 78. -27. 15 8.5 3.9 15.2 135. 673. 77. -27. 14 10.4 2.9 4.9 213. 710. 82. -28. 13 12.9 3.6 7.2 272. 749. 79. -31. 12 15.2 3.3 11.7 273. 790. 81. -34. 11 16.8 3.2 13.9 280. 822. 81. -36. 10 17.5 2.8 14.8 286. 844. 83. -37. 9 18.2 2.1 16.0 289. 866. 87. -38. 8 18.9 1.3 17.1 290. 889. 92. -34. 7 20.0 0.7 16.5 289. 913. 96. -25. 6 21.0 0.6 14.8 295. 938. 97. -15. 5 21.8 0.5 15.2 304. 959. 97. -11. 4 22.5 0.1 16.3 304. 975. 99. -11. 3 23.3 0.1 14.3 292. 988. 100. -10. 2 23.9 0.2 10.8 284. 999. 99. -6. 1 24.4 0.6 9.1 282. 1005. 96. -1. PRCP(HR)=.282 PRCP(TOT)= 0.282 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408230800 787935 **************************************************** PBO 2408230800 FORECAST PROJECTION=50 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -75.3 9.1 39.9 85. 104. 23. -1. 43 -74.2 9.0 37.0 88. 112. 24. -2. 42 -73.2 8.3 39.4 90. 120. 28. -2. 41 -71.5 5.9 39.2 78. 129. 41. -1. 40 -70.0 4.7 42.7 46. 139. 50. 3. 39 -68.7 4.7 50.1 32. 149. 51. 10. 38 -65.4 4.7 42.6 20. 161. 52. 16. 37 -61.5 4.6 34.4 15. 173. 54. 21. 36 -57.9 4.5 19.9 3. 186. 56. 24. 35 -53.8 4.4 16.9 8. 199. 58. 23. 34 -49.9 4.3 13.9 30. 213. 61. 21. 33 -46.0 4.1 9.8 68. 228. 63. 22. 32 -42.1 3.9 8.9 97. 244. 65. 23. 31 -38.2 3.7 11.8 97. 261. 68. 19. 30 -34.4 3.4 16.2 98. 278. 71. 15. 29 -30.7 3.2 19.0 99. 296. 74. 13. 28 -27.2 2.9 19.8 98. 316. 76. 11. 27 -23.8 2.5 19.6 98. 336. 80. 9. 26 -20.7 2.0 18.6 96. 357. 84. 5. 25 -17.7 1.5 16.6 97. 380. 88. 1. 24 -14.7 1.5 14.7 103. 403. 89. -1. 23 -11.9 1.4 16.6 110. 428. 89. -4. 22 -9.3 1.3 20.3 117. 454. 90. -5. 21 -6.7 1.5 22.1 122. 481. 89. -3. 20 -4.0 2.0 22.9 122. 509. 86. 2. 19 -1.4 2.4 23.8 121. 539. 84. 9. 18 1.5 3.5 25.0 121. 570. 78. 14. 17 3.6 3.7 25.2 125. 602. 77. 17. 16 6.3 4.4 24.0 134. 636. 73. 18. 15 9.1 5.1 19.6 137. 672. 71. 16. 14 11.5 4.8 12.7 140. 709. 72. 11. 13 13.6 4.6 7.0 206. 748. 74. 6. 12 15.6 4.5 9.2 255. 789. 74. 1. 11 17.3 4.9 9.9 275. 821. 73. -3. 10 18.2 4.6 11.5 292. 843. 75. -5. 9 19.0 3.9 15.2 307. 865. 78. -5. 8 19.3 3.1 20.3 304. 887. 82. -3. 7 20.4 2.4 20.6 293. 912. 86. -1. 6 21.6 1.9 20.1 289. 936. 89. 0. 5 22.3 1.7 21.1 292. 957. 90. 1. 4 22.8 1.7 21.2 295. 974. 90. 0. 3 23.1 1.4 19.3 296. 987. 92. -0. 2 23.6 1.0 14.7 289. 998. 94. -0. 1 24.0 1.2 12.8 288. 1003. 93. 1. PRCP(HR)=.006 PRCP(TOT)= 0.006 SFC PRES=1006. **************************************************** STATION = 9.35N 82.25W PBO 2408230900 787935 **************************************************** PBO 2408230900 FORECAST PROJECTION=51 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -75.3 8.4 23.9 145. 104. 26. 2. 43 -74.4 8.9 25.0 145. 112. 24. 5. 42 -74.2 7.5 18.2 113. 120. 31. 4. 41 -72.1 5.1 29.1 73. 129. 46. 1. 40 -70.6 4.7 62.8 38. 139. 50. -4. 39 -67.5 4.7 80.7 31. 149. 51. -8. 38 -63.7 4.6 72.3 28. 161. 53. -12. 37 -60.2 4.6 55.3 22. 173. 55. -15. 36 -56.7 4.5 44.9 16. 186. 57. -17. 35 -52.9 4.4 37.8 14. 199. 59. -20. 34 -49.2 4.2 27.6 6. 213. 61. -24. 33 -45.5 4.1 17.8 345. 228. 64. -25. 32 -41.9 3.9 7.5 317. 244. 66. -26. 31 -38.2 3.7 3.7 185. 261. 68. -26. 30 -34.5 3.4 6.6 145. 278. 71. -25. 29 -30.8 3.2 9.6 130. 297. 74. -22. 28 -27.3 2.9 12.8 127. 316. 76. -20. 27 -23.9 2.5 15.6 127. 336. 80. -18. 26 -20.9 1.9 17.1 130. 358. 85. -15. 25 -17.9 1.5 18.3 134. 380. 88. -12. 24 -15.0 1.3 20.4 136. 403. 90. -7. 23 -12.3 1.1 22.4 135. 428. 91. -1. 22 -9.7 0.9 23.1 134. 454. 93. 5. 21 -7.3 0.8 22.9 130. 481. 94. 8. 20 -4.9 0.8 24.2 122. 509. 94. 10. 19 -2.6 0.9 26.5 118. 539. 94. 10. 18 -0.2 1.2 27.5 120. 570. 92. 9. 17 2.3 1.3 25.3 127. 603. 91. 8. 16 5.3 1.7 20.3 141. 637. 89. 7. 15 7.7 1.8 16.1 143. 672. 88. 4. 14 10.1 2.3 11.1 151. 710. 85. -0. 13 12.7 3.1 8.1 214. 749. 81. -3. 12 14.9 3.4 6.7 281. 789. 80. -7. 11 16.3 2.8 10.7 309. 821. 83. -11. 10 17.4 3.0 14.0 304. 843. 83. -15. 9 18.7 3.4 14.7 297. 866. 81. -18. 8 19.7 2.8 15.2 297. 888. 84. -19. 7 20.6 2.2 16.9 305. 912. 87. -18. 6 21.5 2.1 17.7 318. 937. 88. -14. 5 22.4 2.1 18.5 328. 958. 88. -9. 4 23.0 1.8 18.3 333. 974. 89. -5. 3 23.5 1.7 15.1 334. 987. 90. -3. 2 23.8 1.4 10.9 331. 998. 92. -1. 1 24.0 1.2 7.0 330. 1004. 93. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1006. **************************************************** STATION = 9.35N 82.25W PBO 2408231000 787935 **************************************************** PBO 2408231000 FORECAST PROJECTION=52 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -75.4 8.4 26.7 139. 104. 26. 2. 43 -73.3 9.6 23.7 132. 112. 22. 4. 42 -72.5 10.0 23.4 113. 120. 21. 3. 41 -70.7 9.3 25.9 95. 129. 24. -2. 40 -69.3 5.2 30.3 51. 139. 47. -6. 39 -68.0 4.7 44.5 19. 149. 51. -10. 38 -65.4 4.7 51.9 13. 161. 52. -12. 37 -61.6 4.6 49.7 15. 173. 54. -12. 36 -57.4 4.5 46.1 18. 186. 56. -14. 35 -53.2 4.4 44.5 18. 199. 59. -19. 34 -49.2 4.2 38.5 22. 213. 61. -23. 33 -45.6 4.1 24.5 28. 228. 63. -21. 32 -42.0 4.0 5.6 39. 244. 65. -14. 31 -38.1 5.3 4.5 164. 261. 57. -10. 30 -34.3 5.4 9.5 159. 278. 58. -8. 29 -30.6 4.9 13.7 150. 297. 62. -7. 28 -27.0 4.4 17.3 140. 316. 66. -7. 27 -23.5 4.2 19.6 135. 336. 68. -8. 26 -20.3 3.7 20.5 135. 358. 73. -9. 25 -17.3 3.1 22.5 133. 380. 77. -9. 24 -14.4 3.1 24.9 131. 404. 77. -7. 23 -11.5 3.3 25.8 132. 428. 77. -5. 22 -8.9 3.0 26.1 136. 454. 79. -4. 21 -6.6 2.2 26.4 137. 481. 84. -4. 20 -4.4 2.1 27.4 131. 509. 86. -5. 19 -2.2 2.2 28.7 124. 539. 85. -4. 18 0.0 1.6 29.0 122. 570. 89. -1. 17 2.2 0.7 25.8 127. 603. 95. 3. 16 4.8 1.2 18.7 145. 637. 92. 7. 15 7.4 2.2 15.2 175. 673. 86. 12. 14 9.5 1.9 11.6 187. 710. 88. 16. 13 11.6 1.7 8.8 228. 749. 89. 19. 12 13.8 1.4 10.7 277. 790. 91. 21. 11 15.4 1.5 17.3 290. 822. 91. 22. 10 16.6 1.5 20.0 293. 844. 91. 23. 9 17.5 1.4 21.2 297. 866. 92. 23. 8 18.5 1.2 21.5 305. 888. 92. 20. 7 19.4 0.6 22.2 314. 913. 96. 11. 6 20.8 0.1 22.8 324. 938. 100. -2. 5 22.3 0.1 21.8 329. 958. 100. -12. 4 23.1 0.1 20.8 329. 975. 100. -14. 3 23.7 0.2 18.3 327. 988. 99. -8. 2 24.6 1.0 16.1 326. 999. 94. -2. 1 25.0 1.2 11.2 323. 1005. 93. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408231100 787935 **************************************************** PBO 2408231100 FORECAST PROJECTION=53 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -75.5 8.4 16.1 99. 104. 26. -1. 43 -72.9 10.0 17.7 95. 112. 21. -2. 42 -70.7 11.6 23.4 95. 120. 17. -2. 41 -69.2 12.1 28.1 88. 129. 16. -2. 40 -67.2 11.9 32.3 53. 139. 17. -2. 39 -65.9 8.7 39.7 23. 149. 29. -3. 38 -65.4 4.7 41.0 5. 161. 52. -6. 37 -62.0 4.6 39.1 12. 173. 54. -9. 36 -57.7 4.5 38.5 16. 186. 56. -12. 35 -53.7 4.4 32.6 19. 199. 58. -14. 34 -49.9 4.3 22.8 28. 213. 61. -12. 33 -46.1 4.1 7.2 36. 228. 63. -6. 32 -42.4 3.9 2.9 187. 244. 65. -3. 31 -38.6 3.7 8.4 178. 261. 68. -5. 30 -34.7 3.4 12.4 157. 278. 71. -10. 29 -30.9 3.2 15.5 149. 297. 73. -15. 28 -27.4 2.9 18.1 140. 316. 76. -19. 27 -24.1 2.5 21.9 131. 336. 80. -23. 26 -21.0 1.7 24.5 127. 358. 86. -27. 25 -17.8 1.4 22.7 129. 380. 89. -29. 24 -14.8 1.0 20.4 136. 404. 92. -31. 23 -12.1 0.6 19.8 144. 428. 96. -26. 22 -9.6 0.3 20.4 145. 454. 98. -14. 21 -7.1 0.2 21.9 139. 481. 98. -2. 20 -4.4 1.0 24.6 129. 510. 93. 4. 19 -1.8 2.0 26.9 122. 540. 86. 8. 18 1.0 3.1 27.8 118. 571. 80. 6. 17 3.2 2.6 27.7 117. 603. 83. 1. 16 5.9 2.7 23.5 125. 637. 83. -4. 15 8.4 3.4 14.4 146. 673. 79. -8. 14 10.5 3.6 10.9 194. 710. 78. -11. 13 12.5 3.1 10.4 242. 749. 81. -11. 12 14.6 3.0 12.4 275. 790. 82. -8. 11 16.1 3.3 16.5 294. 822. 81. -6. 10 17.0 3.1 19.1 302. 844. 82. -5. 9 18.2 3.5 21.8 300. 866. 80. -3. 8 19.4 3.6 23.2 298. 889. 80. -1. 7 20.4 2.6 25.2 305. 913. 85. 1. 6 20.8 0.4 25.0 311. 938. 98. 0. 5 21.7 0.1 20.1 311. 959. 100. -5. 4 22.8 0.1 16.7 308. 975. 100. -9. 3 23.8 0.6 15.0 305. 989. 97. -9. 2 24.7 1.2 12.8 299. 999. 93. -7. 1 25.1 1.4 10.5 294. 1005. 92. -2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408231200 787935 **************************************************** PBO 2408231200 FORECAST PROJECTION=54 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.2 7.7 24.6 129. 104. 29. 0. 43 -75.0 8.1 28.5 127. 112. 28. 0. 42 -73.2 8.5 31.6 121. 120. 26. -0. 41 -70.8 8.8 30.8 112. 129. 26. 1. 40 -69.8 6.4 33.9 38. 139. 39. 5. 39 -68.5 4.7 48.8 11. 149. 51. 9. 38 -65.1 4.6 50.5 8. 161. 52. 9. 37 -61.1 4.6 46.7 11. 173. 54. 6. 36 -57.1 4.5 39.7 13. 186. 56. 3. 35 -53.1 4.4 35.4 14. 199. 59. 2. 34 -49.2 4.2 31.1 19. 213. 61. -0. 33 -45.8 4.1 14.6 39. 228. 63. -3. 32 -42.1 3.9 4.2 45. 244. 66. -6. 31 -38.3 4.4 5.5 228. 261. 63. -7. 30 -34.7 4.0 12.4 200. 278. 67. -6. 29 -31.1 3.2 13.3 183. 297. 73. -4. 28 -27.5 2.9 15.1 169. 316. 76. -3. 27 -24.2 2.5 17.8 156. 336. 79. -2. 26 -21.3 2.2 17.7 138. 358. 82. 0. 25 -18.3 2.2 18.8 122. 380. 83. 3. 24 -15.1 2.4 21.4 125. 404. 82. 8. 23 -12.1 2.6 23.6 135. 428. 81. 12. 22 -9.2 2.6 24.5 142. 454. 81. 16. 21 -6.4 2.5 24.7 143. 481. 82. 17. 20 -3.9 2.3 25.3 139. 510. 84. 16. 19 -1.8 1.6 25.3 137. 540. 89. 13. 18 0.3 0.8 24.8 135. 571. 94. 10. 17 2.3 0.3 23.6 131. 603. 98. 9. 16 5.1 1.1 20.3 128. 637. 93. 8. 15 7.7 2.1 14.6 137. 673. 86. 6. 14 10.0 2.5 8.7 183. 710. 84. 4. 13 12.1 2.5 9.1 257. 749. 85. 2. 12 14.0 2.0 12.6 295. 790. 88. 5. 11 15.4 1.5 17.2 311. 822. 91. 15. 10 16.2 1.3 20.7 315. 844. 92. 29. 9 17.4 1.5 23.2 315. 867. 91. 45. 8 18.8 1.4 24.5 314. 889. 91. 56. 7 20.2 1.0 25.2 317. 913. 94. 59. 6 21.5 0.7 24.8 317. 938. 96. 50. 5 22.4 0.6 23.2 314. 959. 97. 34. 4 23.1 0.5 21.0 307. 975. 97. 19. 3 23.8 0.8 18.1 302. 989. 95. 10. 2 24.3 0.9 13.8 295. 999. 94. 5. 1 24.6 1.1 11.2 292. 1005. 93. 2. PRCP(HR)=.049 PRCP(TOT)= 0.049 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408231300 787935 **************************************************** PBO 2408231300 FORECAST PROJECTION=55 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.0 6.7 24.9 116. 104. 34. -1. 43 -76.2 6.4 26.7 118. 112. 36. -2. 42 -74.3 7.2 33.2 107. 120. 32. -2. 41 -72.1 8.0 40.0 91. 129. 29. -0. 40 -69.1 9.3 39.9 80. 139. 25. 2. 39 -65.9 8.8 28.8 62. 150. 28. 3. 38 -63.5 6.4 35.5 15. 161. 42. 3. 37 -61.5 5.2 39.6 8. 173. 50. 4. 36 -58.2 4.5 33.5 15. 186. 56. 4. 35 -54.3 4.4 25.9 26. 199. 58. 4. 34 -50.5 4.3 19.2 32. 213. 60. 3. 33 -46.4 4.1 11.6 24. 228. 63. 2. 32 -42.3 3.9 4.9 352. 244. 65. 3. 31 -38.5 3.9 5.9 246. 261. 66. 3. 30 -34.9 3.8 8.9 219. 278. 68. 1. 29 -31.1 3.6 10.0 193. 297. 70. -2. 28 -27.3 3.7 11.0 166. 316. 71. -4. 27 -24.0 4.2 13.2 131. 337. 68. -5. 26 -20.9 4.6 18.3 114. 358. 66. -5. 25 -17.8 5.0 20.3 114. 380. 65. -5. 24 -14.7 5.1 19.2 122. 404. 65. -5. 23 -11.6 4.9 18.1 132. 428. 67. -6. 22 -8.8 4.4 18.1 139. 454. 70. -7. 21 -6.2 3.8 18.3 144. 481. 75. -7. 20 -3.5 3.2 18.6 149. 510. 78. -6. 19 -1.1 2.5 18.7 152. 540. 83. -2. 18 1.1 2.2 18.3 150. 571. 85. 3. 17 3.3 2.2 17.2 142. 603. 86. 9. 16 5.7 2.4 16.6 129. 637. 85. 15. 15 8.1 2.7 14.2 124. 673. 83. 18. 14 9.6 1.4 4.3 124. 710. 91. 12. 13 12.3 0.0 6.8 322. 750. 100. 1. 12 14.2 0.0 11.3 296. 790. 100. -14. 11 15.6 0.0 14.6 290. 822. 100. -24. 10 16.4 0.0 17.1 294. 845. 100. -24. 9 17.5 1.2 20.8 296. 867. 93. -15. 8 18.9 1.8 21.6 300. 889. 89. -7. 7 19.9 0.8 19.7 306. 914. 95. -3. 6 20.8 0.4 19.6 315. 939. 97. 1. 5 21.9 0.1 18.3 320. 959. 100. 4. 4 22.7 0.1 15.5 318. 976. 99. 6. 3 23.1 0.7 13.3 307. 989. 96. 6. 2 23.5 0.9 9.3 302. 1000. 95. 5. 1 23.9 1.0 7.0 303. 1006. 94. 2. PRCP(HR)=.082 PRCP(TOT)= 0.082 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408231400 787935 **************************************************** PBO 2408231400 FORECAST PROJECTION=56 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.4 6.3 23.6 149. 104. 36. 1. 43 -78.3 4.7 23.8 135. 112. 47. 5. 42 -76.7 4.8 25.9 111. 120. 47. 8. 41 -74.1 5.0 30.2 84. 129. 46. 10. 40 -70.9 6.8 37.8 72. 139. 36. 10. 39 -67.5 7.3 38.3 63. 150. 35. 9. 38 -63.7 6.9 34.0 49. 161. 38. 8. 37 -60.6 5.5 36.6 23. 173. 48. 6. 36 -57.3 4.7 35.2 16. 186. 55. 5. 35 -53.6 4.8 28.8 30. 199. 56. 5. 34 -50.4 5.3 17.8 59. 214. 53. 7. 33 -46.5 5.6 10.9 76. 229. 53. 7. 32 -42.2 5.8 5.6 67. 244. 53. 7. 31 -38.2 6.1 1.9 211. 261. 52. 6. 30 -34.5 6.1 9.1 201. 279. 54. 7. 29 -31.0 4.7 12.6 186. 297. 63. 6. 28 -27.3 4.2 15.1 163. 316. 68. 6. 27 -24.1 4.4 19.0 137. 337. 67. 5. 26 -20.8 6.1 22.6 127. 358. 58. 5. 25 -17.7 6.3 22.7 131. 381. 58. 5. 24 -14.7 5.4 21.5 137. 404. 64. 3. 23 -12.0 4.3 20.7 138. 429. 71. -2. 22 -9.3 3.3 19.5 133. 455. 77. -8. 21 -6.7 2.5 17.5 131. 482. 82. -14. 20 -4.1 1.9 14.7 135. 510. 86. -19. 19 -1.7 1.4 12.9 145. 540. 90. -22. 18 0.7 1.2 12.2 152. 571. 92. -23. 17 3.1 1.7 11.4 149. 604. 89. -22. 16 5.7 2.6 11.1 134. 638. 83. -17. 15 8.1 2.9 10.4 131. 674. 82. -11. 14 10.3 3.0 5.7 155. 711. 82. -7. 13 12.3 2.6 7.0 274. 750. 84. -5. 12 14.3 2.5 13.2 298. 791. 85. -5. 11 16.1 2.9 18.7 305. 823. 83. -3. 10 17.0 2.3 21.9 305. 845. 86. 3. 9 17.9 1.6 22.3 307. 868. 90. 10. 8 18.8 0.7 20.2 310. 890. 96. 16. 7 19.7 0.2 19.0 314. 914. 99. 17. 6 20.9 0.5 18.7 317. 939. 97. 15. 5 21.8 0.3 15.1 329. 960. 98. 10. 4 22.7 0.4 10.9 340. 977. 97. 6. 3 23.9 1.3 9.9 339. 990. 93. 3. 2 24.8 1.9 8.4 337. 1000. 89. 2. 1 25.3 2.2 7.0 335. 1006. 88. 2. PRCP(HR)=.003 PRCP(TOT)= 0.003 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408231500 787935 **************************************************** PBO 2408231500 FORECAST PROJECTION=57 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.0 8.2 16.9 219. 104. 26. -2. 43 -75.8 7.3 14.7 180. 112. 31. -7. 42 -75.7 5.8 16.2 133. 120. 40. -12. 41 -73.4 6.8 21.8 100. 129. 35. -16. 40 -70.3 8.0 31.2 80. 139. 30. -17. 39 -67.5 7.8 34.6 70. 150. 32. -16. 38 -64.2 7.9 32.8 59. 161. 33. -14. 37 -60.6 7.3 29.3 49. 173. 37. -11. 36 -57.9 4.5 24.9 49. 186. 56. -11. 35 -54.7 4.4 21.1 67. 199. 58. -11. 34 -50.8 4.3 19.8 88. 214. 60. -10. 33 -46.6 5.2 17.0 91. 229. 56. -6. 32 -42.4 4.5 12.4 86. 245. 61. -2. 31 -38.5 4.6 5.8 124. 261. 62. 1. 30 -34.6 5.3 9.9 162. 279. 59. 4. 29 -30.6 5.4 14.0 159. 297. 59. 5. 28 -26.9 5.9 17.2 146. 317. 58. 6. 27 -23.4 7.5 18.4 133. 337. 50. 6. 26 -20.2 8.1 18.9 124. 358. 48. 6. 25 -17.4 7.1 18.6 122. 381. 54. 5. 24 -14.8 5.0 17.7 125. 404. 66. 5. 23 -12.3 3.4 17.3 128. 429. 76. 7. 22 -9.6 2.7 16.9 130. 455. 81. 9. 21 -6.9 2.4 15.4 133. 482. 83. 10. 20 -4.1 2.3 13.4 137. 510. 84. 8. 19 -1.3 2.5 12.4 145. 540. 83. 4. 18 1.5 2.8 11.6 156. 571. 82. -0. 17 3.9 3.0 9.8 151. 604. 81. -5. 16 5.8 2.6 8.7 127. 638. 83. -11. 15 8.1 3.0 10.1 112. 674. 81. -16. 14 10.9 3.9 7.5 122. 711. 77. -16. 13 13.1 4.0 4.1 256. 750. 77. -11. 12 14.9 3.6 11.0 287. 791. 79. -9. 11 16.5 3.4 15.3 290. 823. 80. -9. 10 16.7 1.6 19.3 292. 846. 90. -10. 9 17.4 1.1 20.8 294. 868. 94. -9. 8 18.4 0.8 20.3 300. 890. 95. -3. 7 19.4 0.3 18.1 309. 915. 98. 7. 6 20.7 0.2 15.9 317. 939. 99. 14. 5 21.8 0.9 14.0 334. 960. 95. 16. 4 23.0 1.7 13.0 341. 977. 90. 15. 3 24.1 2.4 11.9 341. 990. 87. 12. 2 25.0 2.7 10.0 341. 1001. 85. 7. 1 25.7 3.0 8.1 342. 1007. 84. 3. PRCP(HR)=.027 PRCP(TOT)= 0.027 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408231600 787935 **************************************************** PBO 2408231600 FORECAST PROJECTION=58 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.3 6.8 13.7 237. 104. 33. 1. 43 -77.5 5.1 11.2 181. 112. 44. 2. 42 -76.7 4.7 21.3 136. 120. 47. 2. 41 -74.2 5.2 29.1 113. 129. 45. 1. 40 -71.1 6.4 36.2 95. 139. 38. -0. 39 -68.1 7.2 36.0 84. 150. 35. -1. 38 -64.6 7.6 32.1 71. 161. 34. 1. 37 -61.0 7.2 27.8 48. 173. 38. 3. 36 -57.6 6.3 25.3 37. 186. 44. 4. 35 -54.1 8.1 21.9 44. 199. 36. 5. 34 -50.3 9.6 18.0 66. 214. 31. 5. 33 -46.4 5.3 19.7 98. 229. 55. 4. 32 -42.1 5.9 21.1 109. 245. 52. 2. 31 -37.9 9.2 14.8 124. 261. 37. 1. 30 -33.9 10.8 11.0 149. 279. 33. 1. 29 -29.9 11.6 14.2 159. 297. 31. 1. 28 -26.3 10.4 16.2 144. 317. 37. 2. 27 -23.1 9.6 18.6 122. 337. 41. 3. 26 -20.1 9.4 21.1 120. 358. 43. 3. 25 -17.1 8.2 22.0 128. 381. 49. 3. 24 -14.3 6.6 21.8 135. 404. 57. 3. 23 -11.8 4.7 21.1 137. 429. 68. 4. 22 -9.4 3.1 19.9 135. 455. 78. 5. 21 -7.0 2.2 17.5 133. 482. 84. 7. 20 -4.3 2.0 14.2 136. 510. 86. 10. 19 -1.7 1.8 11.4 149. 540. 87. 12. 18 0.9 1.9 9.5 165. 571. 87. 13. 17 2.9 1.6 9.1 160. 604. 89. 10. 16 4.7 0.9 9.1 140. 638. 94. 5. 15 7.0 0.9 6.3 122. 674. 94. -1. 14 9.6 1.8 2.0 61. 711. 88. -6. 13 12.3 2.8 7.3 311. 750. 83. -9. 12 14.9 3.6 13.6 301. 791. 79. -12. 11 16.6 3.8 17.4 300. 823. 78. -13. 10 17.2 2.8 20.3 301. 846. 84. -13. 9 17.9 2.0 21.3 301. 868. 88. -13. 8 18.8 1.5 20.5 301. 890. 91. -13. 7 19.7 0.6 18.4 304. 915. 96. -14. 6 20.7 0.5 17.1 323. 939. 97. -15. 5 22.1 0.5 14.6 341. 960. 97. -14. 4 23.6 1.7 14.5 341. 977. 90. -10. 3 24.8 2.6 14.3 342. 990. 85. -6. 2 25.8 3.4 13.7 342. 1001. 81. -2. 1 26.6 3.9 12.5 343. 1007. 79. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408231700 787935 **************************************************** PBO 2408231700 FORECAST PROJECTION=59 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.9 6.0 13.6 277. 104. 38. 1. 43 -78.3 5.0 8.4 193. 112. 45. 3. 42 -78.2 4.8 24.2 138. 120. 46. 4. 41 -75.2 4.7 29.8 132. 129. 48. 4. 40 -71.8 4.8 32.3 121. 139. 49. 4. 39 -68.3 6.1 31.3 110. 150. 41. 3. 38 -64.7 9.2 29.0 92. 161. 27. 1. 37 -61.0 9.5 27.6 70. 173. 27. -0. 36 -57.2 10.7 29.0 53. 186. 24. -1. 35 -53.4 11.5 29.5 48. 199. 23. -1. 34 -49.7 10.7 27.1 53. 214. 27. -0. 33 -45.8 11.7 22.2 69. 229. 26. 2. 32 -41.8 8.0 19.1 98. 244. 41. 6. 31 -37.5 10.1 17.2 114. 261. 34. 9. 30 -33.3 11.9 12.6 137. 279. 29. 9. 29 -29.4 11.7 10.4 158. 297. 31. 8. 28 -26.4 9.7 12.7 132. 316. 39. 6. 27 -23.1 10.8 18.0 116. 337. 36. 4. 26 -20.0 9.8 19.9 121. 358. 42. 1. 25 -17.1 8.2 19.9 131. 380. 49. -2. 24 -14.2 5.6 19.9 139. 404. 63. -4. 23 -11.6 2.2 20.1 146. 429. 84. -5. 22 -9.3 1.2 18.7 139. 455. 91. -5. 21 -7.0 1.7 16.5 130. 482. 88. -4. 20 -4.5 1.7 14.6 128. 510. 88. -2. 19 -1.5 2.2 11.3 135. 540. 85. 1. 18 1.4 2.9 8.9 153. 571. 81. 4. 17 4.0 3.2 8.5 169. 604. 79. 8. 16 5.8 2.8 8.7 161. 638. 82. 8. 15 7.6 1.9 7.6 143. 674. 88. 5. 14 9.8 2.0 3.1 123. 711. 87. 1. 13 12.4 2.9 4.2 319. 750. 82. -4. 12 15.0 4.1 10.5 303. 791. 77. -8. 11 17.2 4.6 15.3 310. 823. 75. -8. 10 16.6 0.0 19.1 314. 845. 100. -8. 9 18.0 0.1 17.4 312. 867. 100. -9. 8 18.7 0.1 17.2 317. 890. 100. -4. 7 19.2 0.0 20.8 326. 914. 100. 10. 6 20.7 1.3 23.8 331. 939. 92. 20. 5 21.8 1.6 21.4 334. 960. 91. 20. 4 23.0 1.8 18.1 337. 976. 89. 16. 3 24.1 2.5 16.7 338. 990. 86. 12. 2 25.0 3.2 15.3 338. 1000. 83. 8. 1 25.6 3.5 12.9 338. 1006. 81. 4. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408231800 787935 **************************************************** PBO 2408231800 FORECAST PROJECTION=60 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.7 7.2 10.4 289. 104. 31. 1. 43 -74.8 8.7 8.0 286. 112. 25. 4. 42 -74.4 9.0 8.7 60. 120. 24. 5. 41 -74.7 7.2 25.2 87. 129. 32. 6. 40 -72.4 6.1 28.4 106. 139. 40. 6. 39 -69.2 4.7 28.0 131. 150. 50. 4. 38 -65.0 4.7 30.6 135. 161. 52. 2. 37 -60.6 8.1 31.7 121. 173. 34. 0. 36 -56.4 15.1 32.2 97. 186. 13. 1. 35 -52.7 16.8 29.9 79. 199. 11. 1. 34 -49.2 12.6 26.6 70. 213. 21. -0. 33 -45.5 6.9 22.2 67. 229. 46. -2. 32 -41.8 4.6 16.3 97. 244. 61. -4. 31 -37.4 9.8 17.2 122. 261. 35. -6. 30 -33.3 10.8 15.0 132. 278. 33. -7. 29 -30.0 9.4 11.7 134. 297. 40. -7. 28 -26.8 9.3 14.5 124. 316. 41. -6. 27 -23.5 7.2 17.5 134. 337. 52. -5. 26 -20.1 4.6 20.6 146. 358. 67. -4. 25 -16.9 5.1 22.8 145. 380. 65. -3. 24 -14.4 2.2 18.1 145. 404. 84. -5. 23 -11.7 0.6 14.9 149. 429. 95. -7. 22 -9.3 0.4 16.1 137. 454. 97. -7. 21 -7.1 1.1 16.3 123. 482. 92. -3. 20 -4.5 1.4 14.4 116. 510. 90. -0. 19 -1.8 1.9 10.2 112. 540. 87. 1. 18 1.3 2.7 5.8 106. 571. 82. -0. 17 3.8 2.9 3.6 92. 604. 82. -3. 16 5.8 2.6 3.1 96. 638. 84. -3. 15 7.8 2.3 2.8 124. 673. 85. -1. 14 10.0 2.4 2.5 190. 711. 85. 2. 13 12.7 3.5 4.3 269. 750. 79. 3. 12 14.8 1.9 9.2 300. 790. 88. 6. 11 16.3 2.4 14.7 298. 822. 86. 9. 10 17.5 3.7 18.7 298. 845. 79. 10. 9 18.6 4.2 19.5 302. 867. 76. 9. 8 19.7 4.0 17.9 306. 889. 78. 7. 7 21.0 3.9 16.1 315. 914. 78. 5. 6 22.2 4.3 14.5 327. 938. 77. 1. 5 22.8 2.6 12.2 339. 959. 85. -4. 4 24.2 3.2 10.9 348. 976. 82. -7. 3 25.4 4.0 10.6 351. 989. 78. -5. 2 26.4 4.8 10.2 354. 999. 75. -2. 1 27.2 5.3 9.4 356. 1005. 73. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408231900 787935 **************************************************** PBO 2408231900 FORECAST PROJECTION=61 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.2 7.9 3.5 339. 104. 28. 1. 43 -74.8 9.0 6.1 119. 112. 24. 3. 42 -73.1 10.3 21.3 141. 120. 20. 2. 41 -72.0 11.4 23.9 141. 129. 17. -1. 40 -71.2 8.7 21.9 129. 139. 26. -5. 39 -68.9 4.7 21.4 143. 149. 51. -6. 38 -65.5 4.7 21.4 147. 161. 52. -6. 37 -61.2 5.9 22.4 122. 173. 46. -6. 36 -57.2 8.4 22.4 96. 186. 34. -6. 35 -53.4 7.1 21.3 78. 199. 42. -6. 34 -49.6 5.5 18.0 75. 213. 52. -5. 33 -45.7 4.1 13.2 81. 228. 63. -4. 32 -41.7 3.9 10.1 114. 244. 66. -3. 31 -37.6 4.9 12.4 145. 261. 60. -1. 30 -34.0 4.4 13.8 158. 278. 64. 0. 29 -30.4 7.2 15.1 159. 297. 49. 2. 28 -26.6 10.6 17.4 156. 316. 36. 2. 27 -22.9 12.8 19.4 150. 337. 30. 1. 26 -19.3 11.4 20.9 145. 358. 36. -0. 25 -16.4 6.7 19.3 141. 380. 56. -1. 24 -14.0 2.5 14.7 137. 404. 82. -2. 23 -11.6 1.0 13.6 136. 428. 92. -3. 22 -9.2 1.0 14.7 128. 454. 92. -3. 21 -7.2 1.2 16.5 115. 481. 91. -1. 20 -4.8 0.7 14.9 106. 510. 95. 1. 19 -2.1 1.0 11.3 101. 540. 93. 3. 18 0.9 2.0 6.1 96. 571. 87. 3. 17 3.1 1.9 3.4 109. 603. 87. 2. 16 5.4 2.0 3.8 141. 637. 87. 1. 15 7.6 2.1 4.2 137. 673. 87. 1. 14 10.0 2.4 2.5 135. 710. 85. 1. 13 12.5 2.8 1.5 309. 749. 83. 2. 12 15.0 3.7 8.6 305. 790. 78. 1. 11 17.0 4.6 12.7 308. 822. 74. -1. 10 17.6 3.2 12.3 320. 844. 81. -4. 9 18.4 2.5 10.3 343. 867. 85. -5. 8 19.5 2.6 11.0 6. 889. 85. -5. 7 20.8 2.9 12.2 14. 913. 84. -4. 6 22.2 3.4 11.9 17. 938. 81. -4. 5 23.4 4.3 12.5 3. 959. 77. -5. 4 24.5 3.4 12.0 357. 975. 81. -5. 3 25.7 4.3 11.8 359. 989. 77. -4. 2 26.8 5.1 11.4 0. 999. 74. -1. 1 27.5 5.6 10.5 2. 1005. 72. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408232000 787935 **************************************************** PBO 2408232000 FORECAST PROJECTION=62 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -75.8 8.3 1.1 179. 104. 26. -0. 43 -73.1 10.5 3.5 56. 112. 19. -2. 42 -70.7 12.9 7.3 128. 120. 13. -3. 41 -70.6 12.5 17.4 148. 129. 14. -1. 40 -70.6 9.4 19.7 135. 139. 24. 4. 39 -68.7 5.8 18.3 137. 149. 43. 9. 38 -65.5 4.8 17.1 147. 161. 52. 12. 37 -61.5 5.0 17.5 134. 173. 51. 14. 36 -57.4 8.7 17.1 109. 186. 32. 15. 35 -53.5 7.9 16.5 84. 199. 37. 16. 34 -49.8 5.3 12.9 68. 213. 53. 17. 33 -45.7 4.5 7.3 66. 228. 60. 15. 32 -41.5 4.7 3.4 125. 244. 60. 14. 31 -37.2 6.2 8.2 176. 261. 52. 10. 30 -33.1 9.2 12.6 175. 278. 39. 4. 29 -29.2 12.1 14.2 166. 297. 30. -3. 28 -25.8 8.4 14.4 153. 316. 45. -9. 27 -22.7 7.6 14.8 138. 336. 50. -12. 26 -19.7 6.6 15.4 130. 358. 56. -13. 25 -16.9 3.4 13.6 129. 380. 75. -14. 24 -14.3 1.8 12.3 130. 404. 86. -15. 23 -12.0 0.9 12.5 130. 428. 93. -12. 22 -9.5 1.2 14.9 122. 454. 91. -5. 21 -7.1 1.8 17.4 113. 481. 87. 4. 20 -4.5 1.9 17.7 110. 509. 86. 11. 19 -1.8 2.1 14.4 107. 539. 85. 15. 18 1.2 2.7 8.1 100. 570. 82. 15. 17 3.4 2.5 4.1 114. 603. 84. 12. 16 5.5 2.2 4.7 146. 637. 86. 6. 15 8.0 2.7 5.6 132. 673. 83. 2. 14 10.1 2.6 3.8 104. 710. 84. 2. 13 12.3 2.6 1.5 351. 749. 84. 1. 12 14.8 2.7 7.2 318. 790. 84. -0. 11 16.1 1.9 7.2 319. 822. 89. -2. 10 17.1 2.0 5.8 329. 844. 88. -2. 9 18.4 2.6 5.5 353. 866. 85. -1. 8 19.6 2.9 5.7 5. 888. 83. -0. 7 20.8 2.8 4.9 11. 913. 84. -3. 6 22.0 2.9 3.6 8. 937. 84. -7. 5 23.4 3.0 4.2 345. 958. 83. -10. 4 24.9 4.1 4.2 348. 975. 78. -10. 3 26.1 5.1 4.1 351. 988. 74. -8. 2 27.1 5.8 4.0 353. 999. 70. -4. 1 27.8 6.3 3.7 355. 1004. 69. -1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408232100 787935 **************************************************** PBO 2408232100 FORECAST PROJECTION=63 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.2 8.0 7.3 295. 104. 27. 0. 43 -73.4 10.4 3.7 282. 112. 19. 0. 42 -71.3 11.9 11.3 197. 120. 16. 1. 41 -70.2 12.0 16.2 168. 129. 16. 1. 40 -70.3 9.4 16.8 125. 139. 24. 0. 39 -68.7 5.3 16.6 128. 149. 47. -1. 38 -65.7 4.7 16.0 142. 161. 52. -2. 37 -61.7 4.6 17.5 139. 173. 54. -3. 36 -57.7 4.5 16.8 127. 186. 56. -4. 35 -53.8 4.4 13.2 108. 199. 58. -4. 34 -50.0 4.3 9.8 89. 213. 61. -4. 33 -45.9 4.1 5.8 100. 228. 63. -3. 32 -41.6 4.9 8.7 155. 244. 59. -2. 31 -37.4 7.1 13.7 164. 261. 47. -2. 30 -33.8 4.0 15.9 167. 278. 67. -1. 29 -30.5 3.2 15.6 165. 297. 74. -3. 28 -26.9 2.9 15.5 157. 316. 76. -9. 27 -23.4 2.4 15.7 154. 336. 81. -14. 26 -20.3 1.8 13.7 149. 358. 85. -15. 25 -17.3 1.3 11.6 146. 380. 89. -13. 24 -14.6 1.0 10.9 141. 404. 92. -9. 23 -12.0 1.2 12.2 126. 428. 91. -4. 22 -9.5 2.2 15.6 116. 454. 84. -0. 21 -6.9 2.5 17.8 114. 481. 82. 2. 20 -4.2 3.0 18.2 109. 509. 80. 5. 19 -1.8 2.6 16.1 103. 539. 82. 8. 18 1.0 2.5 11.0 89. 570. 83. 10. 17 3.8 3.2 7.4 76. 603. 80. 10. 16 5.9 2.9 4.2 93. 637. 82. 9. 15 7.9 2.6 4.6 113. 673. 83. 5. 14 10.4 3.0 4.4 109. 710. 82. 0. 13 12.7 3.1 0.6 66. 749. 81. -2. 12 14.7 2.3 4.1 328. 790. 86. -2. 11 15.5 1.2 5.0 334. 821. 92. -3. 10 16.7 1.6 4.4 345. 844. 91. -4. 9 18.0 1.8 4.7 347. 866. 89. -4. 8 19.1 1.8 5.2 343. 888. 90. -2. 7 20.4 1.8 4.6 334. 913. 89. -1. 6 21.6 1.6 6.0 329. 937. 91. -5. 5 23.3 2.6 8.7 335. 958. 86. -10. 4 24.7 3.7 8.6 336. 975. 80. -10. 3 25.9 4.7 8.5 338. 988. 75. -7. 2 26.9 5.4 8.3 339. 998. 72. -4. 1 27.5 5.8 7.8 340. 1004. 71. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408232200 787935 **************************************************** PBO 2408232200 FORECAST PROJECTION=64 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -75.1 8.9 5.4 14. 104. 24. -1. 43 -74.3 9.5 8.5 219. 112. 22. -3. 42 -72.3 10.5 19.2 212. 120. 19. -4. 41 -70.7 10.2 18.5 192. 129. 21. -2. 40 -70.7 7.5 14.6 122. 139. 32. 0. 39 -69.4 4.7 19.0 106. 149. 50. 1. 38 -65.8 4.7 20.9 112. 161. 52. 1. 37 -61.6 4.6 20.4 113. 173. 54. 2. 36 -57.6 4.5 16.8 111. 186. 56. 3. 35 -53.7 4.4 11.0 107. 199. 58. 3. 34 -49.8 4.3 6.7 86. 213. 61. 2. 33 -45.7 4.4 6.0 68. 228. 61. 2. 32 -41.4 8.3 1.3 82. 244. 40. 1. 31 -37.5 6.6 8.3 187. 261. 50. -2. 30 -34.0 3.5 12.0 177. 278. 71. -7. 29 -30.2 3.1 10.4 168. 297. 74. -13. 28 -26.5 2.8 9.1 167. 316. 77. -16. 27 -23.2 2.4 8.7 158. 336. 81. -12. 26 -20.2 1.9 9.4 145. 358. 85. -6. 25 -17.0 2.6 10.3 140. 380. 80. -1. 24 -14.3 3.1 12.2 132. 404. 77. 2. 23 -11.7 3.3 15.7 126. 428. 76. 4. 22 -9.2 2.9 18.4 122. 454. 80. 4. 21 -6.7 2.9 19.3 116. 481. 80. 2. 20 -3.9 3.7 19.6 106. 510. 75. -1. 19 -1.4 3.5 18.2 102. 539. 77. -3. 18 0.8 2.4 14.1 101. 570. 84. -5. 17 3.4 2.4 7.4 93. 603. 84. -5. 16 5.4 2.1 3.6 118. 637. 86. -2. 15 7.6 2.1 2.8 148. 673. 87. 3. 14 10.0 2.4 1.9 189. 710. 85. 7. 13 12.6 3.0 3.2 257. 749. 82. 10. 12 14.8 2.7 6.0 317. 790. 84. 11. 11 16.2 2.3 7.3 343. 822. 86. 11. 10 17.2 1.8 6.6 355. 844. 89. 9. 9 18.3 1.7 5.4 351. 866. 90. 7. 8 19.6 1.9 5.3 352. 888. 89. 5. 7 21.1 2.7 5.4 352. 913. 85. 5. 6 22.6 3.5 5.7 345. 938. 81. 6. 5 23.8 4.1 6.1 336. 958. 78. 6. 4 24.7 4.0 8.5 327. 975. 78. 5. 3 25.6 3.5 8.2 322. 988. 81. 4. 2 26.5 4.2 7.8 321. 999. 78. 2. 1 27.0 4.5 7.0 320. 1004. 77. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408232300 787935 **************************************************** PBO 2408232300 FORECAST PROJECTION=65 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.0 8.1 1.9 42. 104. 27. 1. 43 -75.7 7.9 10.9 199. 112. 28. 1. 42 -73.9 9.8 15.8 184. 120. 21. 2. 41 -71.7 10.7 15.4 150. 129. 19. 2. 40 -69.6 9.2 19.8 114. 139. 25. 3. 39 -67.9 7.5 18.3 102. 149. 34. 2. 38 -65.4 6.0 16.9 103. 161. 43. 1. 37 -61.9 5.0 17.2 110. 173. 51. 0. 36 -57.9 4.8 15.6 111. 186. 54. 1. 35 -53.8 5.2 10.2 105. 199. 52. 3. 34 -49.8 5.1 7.3 80. 213. 55. 3. 33 -45.8 4.7 7.4 58. 228. 59. 0. 32 -41.5 7.2 4.8 50. 244. 46. -2. 31 -37.9 5.8 0.3 163. 261. 54. -2. 30 -33.9 5.9 5.6 169. 278. 55. -1. 29 -30.1 4.7 7.1 162. 297. 63. -0. 28 -26.8 5.0 11.9 112. 316. 63. -2. 27 -23.2 9.5 14.7 112. 336. 42. -5. 26 -19.9 8.7 13.4 126. 358. 46. -7. 25 -16.8 6.6 12.1 130. 380. 56. -9. 24 -14.2 4.6 12.7 124. 404. 68. -11. 23 -11.8 2.6 15.8 124. 428. 81. -11. 22 -9.3 2.5 17.6 120. 454. 82. -9. 21 -6.6 3.5 17.4 111. 481. 76. -5. 20 -4.0 4.1 18.2 105. 510. 73. 0. 19 -1.4 4.0 17.3 102. 539. 74. 5. 18 1.0 3.0 12.5 96. 570. 81. 7. 17 3.1 1.9 6.9 86. 603. 87. 5. 16 5.3 1.8 2.8 112. 637. 88. 1. 15 7.8 2.4 2.6 166. 673. 85. -1. 14 10.2 2.7 1.4 151. 710. 83. -1. 13 12.3 2.4 2.4 275. 749. 85. -1. 12 14.5 2.2 4.3 333. 790. 87. 1. 11 15.8 0.5 4.8 359. 822. 97. 4. 10 16.8 0.0 3.3 1. 844. 100. 4. 9 18.1 0.6 2.0 347. 866. 96. 4. 8 19.5 1.2 1.9 33. 889. 93. 2. 7 21.1 2.4 3.8 63. 913. 86. 1. 6 22.7 3.4 2.2 39. 938. 81. -1. 5 24.1 4.8 3.4 332. 959. 75. -2. 4 25.0 4.8 7.3 317. 975. 75. -0. 3 25.6 3.7 10.6 316. 988. 80. 1. 2 26.1 2.7 8.8 321. 999. 85. 2. 1 26.5 2.7 6.3 324. 1005. 85. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408240000 787935 **************************************************** PBO 2408240000 FORECAST PROJECTION=66 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.2 7.8 5.4 279. 104. 28. 0. 43 -75.3 9.1 12.6 234. 112. 23. 1. 42 -73.8 10.8 13.6 193. 120. 18. 1. 41 -71.5 11.3 15.0 150. 129. 17. 1. 40 -69.1 11.5 19.6 107. 139. 18. -0. 39 -67.4 8.1 22.2 91. 150. 31. -1. 38 -65.3 5.4 18.3 93. 161. 47. -2. 37 -62.2 4.6 13.9 97. 173. 54. -3. 36 -58.2 4.5 13.1 96. 186. 56. -4. 35 -54.0 4.4 12.2 92. 199. 58. -3. 34 -49.9 5.6 10.0 80. 213. 52. 0. 33 -45.8 6.1 8.8 66. 229. 50. 2. 32 -41.6 7.0 6.5 72. 244. 46. 2. 31 -37.9 5.2 4.9 137. 261. 58. 2. 30 -34.2 3.4 9.3 125. 278. 71. 0. 29 -30.7 5.8 15.5 111. 297. 57. -1. 28 -27.0 8.5 17.5 116. 316. 44. -2. 27 -23.8 5.9 15.9 128. 337. 58. -3. 26 -21.0 2.7 13.5 139. 358. 79. -1. 25 -17.9 1.9 12.1 140. 380. 85. 2. 24 -14.9 1.5 13.0 131. 404. 88. 4. 23 -12.2 1.3 15.2 124. 429. 90. 3. 22 -9.4 2.2 15.5 119. 454. 84. 2. 21 -6.6 3.5 15.1 113. 482. 76. -1. 20 -3.9 4.8 16.7 105. 510. 69. -3. 19 -1.2 4.9 18.1 102. 540. 69. -5. 18 1.5 4.3 16.9 100. 571. 73. -6. 17 3.9 3.6 11.6 89. 603. 78. -4. 16 6.1 3.1 5.8 75. 638. 81. 0. 15 8.4 3.3 1.1 135. 673. 80. 2. 14 10.7 3.6 0.5 234. 711. 79. 0. 13 12.6 2.9 4.3 297. 750. 83. -2. 12 14.6 2.1 6.0 315. 790. 87. -4. 11 15.6 0.0 5.7 344. 822. 100. -5. 10 16.9 0.0 4.0 353. 845. 100. -7. 9 17.9 0.1 1.9 350. 867. 100. -11. 8 19.0 0.7 1.0 44. 889. 96. -15. 7 20.6 1.8 1.0 329. 914. 89. -15. 6 22.2 3.0 5.3 301. 938. 83. -13. 5 23.7 3.9 10.8 300. 959. 79. -8. 4 24.8 4.0 13.2 298. 976. 78. -3. 3 25.5 3.7 13.6 310. 989. 80. 0. 2 26.0 2.8 11.9 314. 1000. 84. 2. 1 26.3 2.7 8.6 314. 1005. 85. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408240100 787935 **************************************************** PBO 2408240100 FORECAST PROJECTION=67 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -75.9 8.0 2.0 232. 104. 28. -0. 43 -74.2 10.2 9.8 215. 112. 20. 1. 42 -73.0 11.4 17.1 173. 120. 16. 3. 41 -70.6 13.2 21.3 170. 129. 13. 6. 40 -68.3 13.1 20.0 129. 139. 14. 7. 39 -66.7 9.5 23.6 88. 149. 25. 8. 38 -64.4 8.0 25.5 79. 161. 32. 8. 37 -61.5 7.4 21.1 82. 173. 37. 6. 36 -58.2 5.8 12.1 76. 186. 47. 5. 35 -54.3 4.4 11.1 69. 199. 58. 3. 34 -50.2 4.4 13.0 60. 213. 60. 0. 33 -45.9 7.1 14.5 48. 228. 44. -1. 32 -41.8 6.7 10.6 49. 244. 48. -1. 31 -38.0 4.2 6.5 80. 261. 65. -2. 30 -34.3 4.0 9.6 102. 278. 67. -2. 29 -30.6 6.5 16.5 102. 297. 53. -2. 28 -27.1 6.7 17.4 112. 316. 53. -2. 27 -24.0 3.9 16.2 132. 337. 70. -1. 26 -20.9 2.1 12.2 149. 358. 83. -2. 25 -17.8 1.4 10.4 152. 380. 89. -4. 24 -14.9 1.0 10.6 141. 404. 92. -5. 23 -12.0 1.8 13.8 127. 428. 86. -4. 22 -9.3 2.4 14.1 116. 454. 83. -2. 21 -6.5 3.8 13.4 104. 481. 74. -3. 20 -3.6 5.0 14.6 98. 510. 68. -4. 19 -1.1 5.0 16.3 98. 540. 69. -6. 18 1.7 5.2 15.4 102. 571. 69. -6. 17 4.1 4.0 10.6 104. 603. 75. -4. 16 6.1 3.0 4.7 89. 637. 81. -1. 15 8.8 3.9 0.8 191. 673. 77. 0. 14 11.4 4.7 1.3 245. 710. 73. 2. 13 13.4 4.2 5.0 281. 749. 76. 1. 12 15.0 2.5 6.2 299. 790. 85. -2. 11 16.3 1.1 5.5 333. 822. 93. -3. 10 17.1 0.5 4.4 353. 844. 97. -1. 9 18.4 0.7 2.0 322. 867. 96. 3. 8 19.5 1.1 1.4 252. 889. 93. 5. 7 20.8 1.9 1.6 246. 913. 89. 5. 6 22.5 3.4 4.3 284. 938. 81. 3. 5 23.6 3.5 8.7 296. 959. 81. 2. 4 24.2 2.1 11.2 306. 975. 88. 2. 3 24.9 2.0 10.7 305. 989. 89. 1. 2 25.8 3.2 9.2 298. 999. 83. 1. 1 26.1 3.0 6.5 296. 1005. 84. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408240200 787935 **************************************************** PBO 2408240200 FORECAST PROJECTION=68 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.2 7.2 1.9 51. 104. 31. -1. 43 -77.0 8.3 9.4 270. 112. 26. -4. 42 -73.0 11.4 10.6 252. 120. 16. -4. 41 -69.9 14.5 13.9 211. 129. 10. -4. 40 -67.8 14.5 9.8 154. 139. 11. -5. 39 -65.6 13.0 13.2 100. 150. 15. -8. 38 -62.7 12.6 20.9 81. 161. 17. -9. 37 -60.4 10.0 25.6 76. 173. 26. -7. 36 -57.8 7.7 19.8 79. 186. 36. -5. 35 -54.5 4.9 11.7 79. 199. 55. -3. 34 -50.4 4.5 8.2 80. 214. 59. -2. 33 -46.1 5.1 7.4 69. 229. 56. -2. 32 -41.9 5.1 8.9 55. 244. 57. -4. 31 -38.1 4.2 7.4 90. 261. 64. -4. 30 -34.6 4.3 15.3 94. 279. 65. -3. 29 -31.0 5.1 16.4 103. 297. 61. -1. 28 -27.6 3.2 12.7 123. 316. 74. -3. 27 -24.3 2.5 10.0 161. 337. 79. -6. 26 -20.8 1.9 12.1 163. 358. 85. -8. 25 -17.7 1.4 13.7 151. 381. 89. -8. 24 -15.1 1.0 15.0 134. 404. 92. -6. 23 -12.3 1.5 15.6 121. 429. 88. -4. 22 -9.4 2.1 14.1 117. 455. 84. -2. 21 -6.7 2.9 12.1 120. 482. 80. -1. 20 -4.1 2.6 11.7 125. 510. 82. -1. 19 -2.1 1.6 12.4 115. 540. 89. -0. 18 0.4 2.2 11.7 101. 571. 85. -0. 17 3.2 2.2 7.8 95. 604. 86. 1. 16 5.8 2.5 2.3 79. 638. 84. 3. 15 8.4 3.2 0.7 337. 674. 80. 7. 14 10.8 3.7 2.0 339. 711. 78. 10. 13 12.8 3.1 5.0 314. 750. 82. 11. 12 14.7 1.7 6.2 319. 791. 90. 9. 11 15.9 0.3 6.6 339. 823. 98. 6. 10 17.1 0.1 7.3 347. 845. 100. 5. 9 18.6 0.8 6.0 349. 868. 95. 5. 8 20.1 1.7 3.4 354. 890. 90. 6. 7 21.4 2.5 1.7 5. 914. 86. 6. 6 22.9 3.7 1.9 332. 939. 79. 5. 5 24.1 3.9 6.6 314. 960. 79. 3. 4 24.6 3.0 9.9 312. 977. 83. 2. 3 24.9 2.2 10.2 313. 990. 88. 1. 2 25.4 1.8 8.2 311. 1001. 90. 2. 1 25.7 1.9 5.0 307. 1006. 90. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408240300 787935 **************************************************** PBO 2408240300 FORECAST PROJECTION=69 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.2 7.0 4.3 299. 104. 32. -1. 43 -76.4 8.6 11.1 220. 112. 25. -4. 42 -74.3 10.3 18.3 204. 120. 19. -5. 41 -71.5 11.5 22.9 191. 129. 17. -3. 40 -68.8 12.2 18.9 150. 139. 16. -0. 39 -66.4 10.5 25.0 98. 150. 22. 3. 38 -64.0 9.2 29.5 80. 161. 27. 5. 37 -61.1 7.9 26.8 76. 173. 34. 5. 36 -58.3 5.0 18.7 75. 186. 52. 3. 35 -54.6 4.4 12.5 62. 199. 58. 1. 34 -50.5 4.3 8.6 46. 214. 60. -1. 33 -46.2 4.1 7.6 65. 229. 63. -1. 32 -42.2 3.9 10.0 65. 245. 66. -1. 31 -38.4 5.1 12.3 75. 261. 59. -1. 30 -34.8 6.3 16.7 84. 279. 53. -1. 29 -31.2 3.7 14.9 88. 297. 69. -1. 28 -27.8 2.9 6.5 92. 317. 76. -2. 27 -24.4 2.6 3.8 190. 337. 79. -2. 26 -21.0 1.9 6.3 184. 358. 84. -2. 25 -17.9 1.5 9.8 131. 381. 88. -2. 24 -15.2 1.5 14.0 106. 404. 88. -0. 23 -12.3 1.4 13.8 108. 429. 89. 0. 22 -9.5 1.6 13.1 113. 455. 88. -0. 21 -6.6 2.6 12.7 118. 482. 82. -0. 20 -3.7 3.5 11.2 125. 510. 77. 0. 19 -1.3 3.2 10.0 122. 540. 79. 2. 18 0.9 2.6 9.8 104. 571. 83. 2. 17 2.9 1.8 6.4 93. 604. 88. 1. 16 5.5 1.9 1.5 82. 638. 87. -1. 15 8.1 2.6 0.9 337. 674. 83. -4. 14 10.4 3.0 2.3 336. 711. 82. -5. 13 12.8 2.9 5.1 328. 750. 82. -4. 12 15.1 2.2 6.3 330. 791. 86. -3. 11 16.5 1.1 6.5 324. 823. 93. -3. 10 17.3 0.4 7.5 324. 846. 97. -3. 9 18.6 0.9 7.7 334. 868. 95. -1. 8 20.3 2.1 6.9 338. 890. 88. 1. 7 21.8 2.8 2.3 348. 915. 84. 2. 6 23.2 4.0 0.8 323. 940. 78. 1. 5 24.3 4.2 4.7 302. 960. 77. 1. 4 24.6 3.6 10.1 301. 977. 80. 2. 3 24.9 2.6 11.7 304. 990. 85. 2. 2 25.2 2.0 9.2 298. 1001. 89. 1. 1 25.6 2.0 6.9 296. 1007. 89. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408240400 787935 **************************************************** PBO 2408240400 FORECAST PROJECTION=70 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -75.6 7.9 9.3 315. 104. 28. 0. 43 -75.0 9.6 12.7 226. 112. 21. 0. 42 -73.9 9.5 19.2 199. 120. 22. -0. 41 -72.0 10.1 22.7 169. 129. 21. -0. 40 -69.8 9.4 21.1 130. 139. 24. -1. 39 -67.2 8.3 27.4 94. 150. 30. -1. 38 -64.6 7.5 34.2 79. 161. 35. -2. 37 -61.1 8.3 32.1 73. 173. 32. -2. 36 -57.7 6.8 23.9 72. 186. 41. -1. 35 -54.4 4.6 15.2 68. 199. 57. 0. 34 -50.4 5.8 11.3 58. 214. 50. 2. 33 -46.2 6.6 10.5 56. 229. 47. 3. 32 -42.3 6.2 11.7 55. 244. 50. 3. 31 -38.4 8.5 13.9 64. 261. 41. 3. 30 -34.5 9.5 16.0 70. 279. 38. 4. 29 -31.1 6.3 13.7 87. 297. 54. 4. 28 -27.8 3.4 9.3 90. 316. 73. 3. 27 -24.3 3.2 0.5 94. 337. 75. 1. 26 -21.1 2.0 3.1 209. 358. 84. -1. 25 -17.9 2.0 5.5 127. 381. 84. -1. 24 -15.2 1.3 8.5 108. 404. 90. -2. 23 -12.7 0.8 11.3 122. 429. 94. -4. 22 -9.9 1.5 14.4 133. 455. 89. -5. 21 -7.1 1.7 13.9 132. 482. 87. -7. 20 -4.5 1.7 13.0 122. 510. 88. -9. 19 -1.6 2.1 16.9 115. 540. 86. -10. 18 1.2 2.9 13.8 105. 571. 81. -9. 17 3.6 3.1 10.4 89. 604. 80. -7. 16 6.1 3.1 5.5 76. 638. 80. -4. 15 8.7 3.8 2.4 30. 674. 77. -1. 14 11.1 4.2 2.9 337. 711. 75. 0. 13 13.3 3.8 4.8 331. 750. 78. 2. 12 15.3 2.2 6.6 319. 791. 87. 4. 11 16.7 1.4 8.6 311. 823. 92. 6. 10 17.4 0.7 8.9 314. 845. 96. 6. 9 18.5 0.9 8.1 322. 868. 94. 5. 8 19.9 2.0 7.2 320. 890. 88. 4. 7 21.3 2.4 4.4 302. 914. 86. 2. 6 22.7 3.3 6.7 298. 939. 82. 1. 5 23.7 3.5 11.7 299. 960. 81. 1. 4 24.4 3.0 14.1 308. 977. 83. 1. 3 24.6 1.3 12.6 311. 990. 92. 1. 2 25.1 1.3 10.2 301. 1000. 93. 1. 1 25.4 1.3 7.6 286. 1006. 93. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408240500 787935 **************************************************** PBO 2408240500 FORECAST PROJECTION=71 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.6 6.8 3.3 279. 104. 33. -1. 43 -75.5 8.5 11.3 235. 112. 26. -0. 42 -73.6 9.4 15.8 199. 120. 23. 3. 41 -71.8 10.3 21.5 176. 129. 20. 5. 40 -68.6 12.7 22.5 161. 139. 14. 6. 39 -65.7 13.4 19.8 125. 150. 14. 6. 38 -63.7 12.0 29.0 84. 161. 18. 4. 37 -60.8 10.9 36.2 75. 173. 22. 3. 36 -57.0 11.1 32.5 69. 186. 23. 1. 35 -53.6 8.8 21.3 66. 199. 33. 0. 34 -50.2 6.2 13.9 65. 214. 48. 0. 33 -46.2 6.6 11.5 60. 229. 47. -1. 32 -42.2 6.2 11.8 69. 244. 50. -1. 31 -38.2 10.0 15.8 79. 261. 34. -1. 30 -34.6 9.5 18.1 80. 279. 37. -1. 29 -31.8 3.3 13.3 99. 297. 72. -3. 28 -28.4 3.0 5.5 97. 316. 75. -6. 27 -24.4 2.6 1.3 86. 337. 79. -5. 26 -21.2 2.0 3.8 96. 358. 84. -1. 25 -18.1 1.8 9.0 91. 381. 86. 5. 24 -15.3 1.6 11.5 107. 404. 88. 11. 23 -12.5 2.5 15.6 128. 429. 82. 16. 22 -9.7 3.9 17.8 138. 455. 73. 18. 21 -6.8 3.8 15.2 141. 482. 75. 16. 20 -4.3 2.2 11.9 127. 510. 85. 12. 19 -1.7 2.6 16.7 110. 540. 83. 8. 18 1.2 3.2 12.9 106. 571. 79. 4. 17 3.5 3.0 8.9 89. 604. 81. 0. 16 6.1 3.2 5.2 76. 638. 80. -5. 15 8.7 3.7 1.8 37. 674. 78. -10. 14 10.8 3.5 2.1 338. 711. 79. -12. 13 12.8 2.6 3.7 341. 750. 84. -11. 12 14.8 1.6 6.1 327. 791. 90. -6. 11 16.0 0.4 8.8 317. 823. 97. -2. 10 17.1 0.4 9.6 321. 845. 97. -0. 9 18.6 1.4 9.9 324. 867. 92. 1. 8 20.1 2.5 9.3 323. 890. 86. 2. 7 21.7 3.3 8.3 315. 914. 82. 5. 6 23.2 4.2 11.1 306. 939. 77. 7. 5 24.3 4.7 14.6 304. 960. 75. 7. 4 25.0 4.6 16.6 303. 976. 76. 5. 3 25.2 3.6 16.0 303. 990. 80. 4. 2 25.2 2.2 12.3 301. 1000. 88. 2. 1 25.3 1.6 8.2 298. 1006. 91. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408240600 787935 **************************************************** PBO 2408240600 FORECAST PROJECTION=72 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.6 7.1 6.6 170. 104. 32. 0. 43 -77.0 7.0 16.5 217. 112. 32. 1. 42 -74.2 8.3 18.4 201. 120. 27. 1. 41 -71.8 9.4 21.0 189. 129. 24. 1. 40 -68.5 12.1 20.3 177. 139. 16. 1. 39 -65.7 13.3 19.4 134. 150. 14. 1. 38 -63.6 12.3 26.0 91. 161. 17. 0. 37 -61.0 8.9 33.5 77. 173. 30. -0. 36 -57.3 8.4 28.6 67. 186. 34. -0. 35 -53.6 8.1 18.1 58. 199. 37. -1. 34 -50.2 5.8 12.0 62. 214. 50. -1. 33 -46.5 5.3 11.3 75. 229. 54. -3. 32 -42.5 8.4 15.8 77. 244. 39. -4. 31 -38.7 7.5 20.6 73. 261. 45. -4. 30 -35.1 6.8 19.5 74. 279. 50. -3. 29 -31.8 5.1 13.3 81. 297. 61. -1. 28 -28.3 3.9 7.6 77. 316. 69. 1. 27 -24.3 3.2 7.4 64. 337. 75. 1. 26 -20.9 3.2 9.3 68. 358. 75. -0. 25 -17.8 3.4 10.1 74. 380. 75. -0. 24 -14.9 3.1 10.7 95. 404. 77. 0. 23 -11.8 5.5 15.3 131. 429. 64. -1. 22 -8.8 7.4 17.1 145. 454. 55. -3. 21 -6.4 5.4 14.5 152. 482. 66. -4. 20 -4.2 2.6 11.4 142. 510. 82. -4. 19 -1.6 2.5 14.3 124. 540. 83. -3. 18 1.1 3.0 13.3 121. 571. 80. -2. 17 3.5 2.9 7.9 111. 604. 81. -1. 16 5.8 2.6 3.7 90. 638. 83. -1. 15 8.2 2.9 1.4 360. 673. 82. -2. 14 10.6 3.0 2.8 330. 711. 82. -3. 13 12.8 2.5 4.3 336. 750. 84. -4. 12 14.8 1.7 7.2 326. 791. 90. -5. 11 16.5 1.7 9.5 321. 823. 90. -7. 10 17.6 2.0 10.3 320. 845. 88. -8. 9 18.8 2.3 10.7 319. 867. 87. -8. 8 20.2 2.9 10.9 314. 889. 83. -5. 7 21.8 3.8 11.7 309. 914. 79. -1. 6 23.3 4.5 13.4 306. 939. 76. 3. 5 24.4 4.8 15.3 304. 959. 75. 5. 4 25.0 4.5 16.4 307. 976. 76. 6. 3 25.3 3.9 16.3 308. 989. 79. 5. 2 25.2 3.1 12.6 304. 1000. 83. 3. 1 25.3 2.4 9.0 304. 1006. 86. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408240700 787935 **************************************************** PBO 2408240700 FORECAST PROJECTION=73 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.5 6.7 11.1 170. 104. 33. -1. 43 -77.3 6.3 17.5 206. 112. 36. -2. 42 -75.1 6.5 19.3 199. 120. 36. -3. 41 -72.1 8.8 20.8 194. 129. 26. -4. 40 -68.7 12.2 20.2 186. 139. 16. -4. 39 -65.3 14.8 16.4 155. 150. 11. -3. 38 -62.8 14.3 20.2 102. 161. 13. -2. 37 -60.6 9.7 32.6 77. 173. 27. -1. 36 -57.4 8.1 30.8 68. 186. 35. -1. 35 -53.9 6.9 21.2 61. 199. 42. -1. 34 -50.4 5.0 14.6 60. 214. 55. -1. 33 -46.7 5.0 15.5 63. 229. 57. -0. 32 -42.7 6.0 20.8 63. 244. 52. 1. 31 -38.6 7.8 23.8 67. 261. 44. 3. 30 -35.0 6.6 21.2 74. 279. 51. 4. 29 -31.6 5.7 17.1 81. 297. 57. 4. 28 -28.1 6.1 12.4 84. 316. 56. 4. 27 -24.3 6.1 10.7 91. 337. 57. 3. 26 -21.0 4.4 8.8 91. 358. 68. 2. 25 -18.5 2.2 8.1 102. 380. 83. 1. 24 -15.5 3.7 11.2 135. 404. 73. 0. 23 -12.3 5.6 15.1 144. 429. 63. -0. 22 -9.6 4.9 14.5 150. 454. 67. -1. 21 -7.1 3.2 12.6 152. 482. 78. -1. 20 -4.5 2.2 11.6 142. 510. 85. -1. 19 -1.6 2.5 12.2 135. 540. 83. -3. 18 1.1 2.7 12.2 134. 571. 82. -4. 17 3.4 2.8 9.1 120. 604. 82. -5. 16 5.9 2.9 5.4 91. 638. 81. -6. 15 8.1 2.5 2.7 22. 673. 84. -6. 14 10.4 2.6 3.7 335. 711. 84. -4. 13 12.5 2.1 5.0 328. 750. 87. -3. 12 14.6 1.4 7.0 320. 791. 91. -4. 11 16.1 1.3 8.5 309. 823. 92. -6. 10 17.2 1.4 9.0 307. 845. 91. -7. 9 18.4 2.0 9.7 314. 867. 88. -8. 8 19.8 2.8 11.1 317. 889. 84. -9. 7 21.4 3.4 12.1 315. 914. 81. -8. 6 22.9 4.1 12.7 322. 939. 78. -7. 5 24.0 4.5 16.5 324. 959. 76. -4. 4 24.6 4.1 20.3 321. 976. 78. -1. 3 24.9 3.1 17.2 318. 989. 83. 1. 2 25.1 2.5 12.7 312. 1000. 86. 1. 1 25.0 1.9 8.2 307. 1006. 89. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408240800 787935 **************************************************** PBO 2408240800 FORECAST PROJECTION=74 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.2 6.8 10.8 166. 104. 33. -0. 43 -77.1 6.2 16.5 195. 112. 37. -0. 42 -75.0 6.8 18.5 193. 120. 34. -0. 41 -72.2 8.9 20.0 186. 129. 25. -0. 40 -68.7 12.4 19.6 180. 139. 15. -1. 39 -65.3 15.1 18.0 157. 150. 11. -1. 38 -62.8 14.1 19.7 112. 161. 13. -0. 37 -60.2 11.5 30.4 84. 173. 21. -0. 36 -57.2 8.9 31.9 73. 186. 31. 0. 35 -53.9 7.4 21.9 59. 199. 40. 1. 34 -50.6 4.8 15.9 49. 214. 57. 1. 33 -46.8 4.1 18.0 50. 229. 63. 0. 32 -42.8 4.4 21.9 56. 244. 62. -0. 31 -38.9 6.5 23.3 70. 261. 50. -0. 30 -35.3 5.0 23.2 86. 279. 60. 1. 29 -31.6 5.3 20.6 95. 297. 59. 2. 28 -27.9 5.9 17.0 101. 316. 57. 3. 27 -24.3 6.7 11.6 94. 337. 54. 2. 26 -21.1 4.7 9.2 99. 358. 66. 2. 25 -18.6 2.8 10.3 124. 380. 79. 2. 24 -15.6 4.8 15.4 138. 404. 66. 4. 23 -12.7 5.4 16.5 140. 429. 64. 5. 22 -10.1 3.9 13.5 143. 454. 73. 5. 21 -7.4 2.6 10.7 145. 482. 82. 4. 20 -4.6 2.1 9.0 137. 510. 85. 3. 19 -1.8 2.2 8.6 132. 540. 85. 1. 18 0.8 2.3 8.3 138. 571. 84. -1. 17 3.2 2.4 5.7 133. 604. 84. -2. 16 5.9 3.0 2.6 98. 638. 81. -2. 15 8.2 2.6 2.9 333. 673. 83. 0. 14 10.5 2.6 5.0 322. 711. 84. 2. 13 12.4 1.7 6.1 331. 750. 90. 3. 12 14.2 0.9 6.9 327. 791. 94. 3. 11 15.6 0.8 8.5 322. 823. 95. 1. 10 16.9 1.4 10.0 321. 845. 91. -0. 9 18.3 2.3 9.8 322. 867. 86. -1. 8 19.7 3.2 9.4 326. 889. 82. -2. 7 21.4 4.0 11.3 328. 914. 78. -1. 6 22.9 5.0 15.9 324. 939. 73. 0. 5 23.8 4.6 19.0 321. 959. 75. 2. 4 24.2 3.5 19.4 316. 976. 81. 2. 3 24.7 2.7 15.0 311. 989. 85. 2. 2 25.3 2.9 12.2 307. 1000. 84. 1. 1 25.4 2.3 8.3 299. 1006. 87. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408240900 787935 **************************************************** PBO 2408240900 FORECAST PROJECTION=75 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.3 6.9 10.3 169. 104. 33. 1. 43 -76.9 6.2 15.9 191. 112. 37. 3. 42 -75.0 6.6 16.8 190. 120. 36. 4. 41 -72.4 8.4 17.7 186. 129. 27. 4. 40 -68.9 11.5 17.3 164. 139. 18. 3. 39 -65.7 14.1 19.1 131. 149. 12. 3. 38 -62.4 14.9 21.1 106. 161. 12. 1. 37 -59.7 12.3 31.6 85. 173. 19. -0. 36 -57.2 8.7 34.7 75. 186. 32. -2. 35 -53.7 9.1 27.5 60. 199. 32. -3. 34 -50.1 8.9 20.7 46. 213. 34. -3. 33 -46.4 7.3 19.8 48. 228. 43. -3. 32 -42.5 7.2 23.5 57. 244. 45. -4. 31 -38.7 7.9 23.5 71. 261. 43. -5. 30 -35.3 6.8 23.3 93. 278. 50. -7. 29 -31.7 5.5 22.5 100. 297. 58. -8. 28 -28.1 5.0 21.1 100. 316. 62. -10. 27 -24.5 4.6 17.4 103. 336. 66. -11. 26 -21.2 4.2 12.4 101. 358. 69. -11. 25 -18.5 3.3 10.8 123. 380. 75. -11. 24 -15.5 5.3 15.7 140. 404. 64. -12. 23 -12.8 4.4 16.1 139. 428. 69. -10. 22 -10.1 3.9 11.4 135. 454. 73. -7. 21 -7.2 3.7 8.5 136. 481. 75. -4. 20 -4.2 3.6 7.1 129. 510. 76. 0. 19 -1.3 3.6 7.1 126. 539. 76. 4. 18 1.3 3.5 6.8 136. 570. 78. 6. 17 3.6 3.2 4.2 146. 603. 80. 7. 16 6.1 3.5 1.3 115. 637. 78. 6. 15 8.6 3.6 3.6 348. 673. 78. 4. 14 11.0 3.4 6.4 342. 710. 79. 3. 13 12.5 1.9 8.4 337. 749. 88. 3. 12 14.3 0.9 8.8 333. 790. 94. 3. 11 16.0 1.4 9.8 326. 822. 92. 3. 10 17.2 1.7 10.3 321. 844. 90. 3. 9 18.4 2.1 9.2 318. 866. 88. 4. 8 19.8 3.0 8.8 313. 889. 83. 4. 7 21.4 4.2 12.2 306. 913. 77. 4. 6 22.6 3.1 15.0 310. 938. 83. 4. 5 23.3 2.8 17.8 312. 959. 84. 3. 4 23.4 1.3 18.3 308. 975. 92. 2. 3 24.3 1.8 16.1 303. 988. 90. 1. 2 24.9 2.5 12.9 294. 999. 86. 1. 1 25.0 2.3 9.4 283. 1005. 87. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408241000 787935 **************************************************** PBO 2408241000 FORECAST PROJECTION=76 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.3 7.0 6.1 192. 104. 32. 0. 43 -76.4 6.9 13.2 201. 112. 33. 1. 42 -74.7 7.0 17.0 195. 120. 33. 1. 41 -72.2 8.6 17.3 185. 129. 27. 0. 40 -68.9 11.3 15.8 160. 139. 18. -1. 39 -65.8 13.0 19.6 122. 150. 15. -2. 38 -62.7 12.5 27.6 100. 161. 17. -3. 37 -60.2 8.8 36.1 88. 173. 31. -4. 36 -57.3 7.1 37.7 78. 186. 40. -4. 35 -53.8 8.3 28.4 63. 199. 36. -3. 34 -50.1 7.8 23.1 45. 214. 39. -3. 33 -46.2 7.9 19.8 45. 229. 40. -3. 32 -42.3 8.0 22.4 54. 244. 41. -3. 31 -38.4 10.5 26.3 62. 261. 32. -4. 30 -35.1 8.2 21.8 89. 279. 43. -5. 29 -31.5 6.8 19.5 109. 297. 51. -5. 28 -28.0 5.3 17.6 106. 316. 60. -5. 27 -24.6 3.6 16.6 101. 337. 72. -5. 26 -21.4 3.5 9.6 110. 358. 73. -4. 25 -18.3 4.7 7.9 143. 380. 67. -2. 24 -15.3 4.4 13.4 148. 404. 69. 1. 23 -12.3 3.5 15.3 143. 429. 75. 3. 22 -9.5 3.9 12.0 146. 454. 73. 5. 21 -6.8 4.5 6.7 146. 482. 71. 6. 20 -4.0 4.2 5.2 130. 510. 73. 6. 19 -1.4 3.6 6.7 129. 540. 77. 4. 18 0.9 2.7 7.1 150. 571. 82. 1. 17 3.1 2.2 5.5 168. 604. 85. 0. 16 5.4 2.2 2.0 151. 638. 85. -1. 15 7.8 2.0 3.7 21. 673. 87. -2. 14 9.8 1.5 7.9 9. 711. 90. -4. 13 11.6 0.5 8.6 5. 750. 97. -6. 12 13.7 0.0 8.1 357. 791. 100. -9. 11 15.3 0.0 9.1 345. 823. 100. -12. 10 16.5 0.6 9.6 335. 845. 96. -12. 9 18.1 1.9 10.4 324. 867. 89. -12. 8 19.5 2.1 12.3 317. 890. 87. -12. 7 20.8 1.5 13.8 319. 914. 91. -11. 6 22.0 1.4 16.1 325. 939. 92. -9. 5 23.2 2.1 19.5 323. 960. 88. -5. 4 23.9 2.3 19.9 318. 976. 87. -1. 3 24.4 2.6 17.4 310. 989. 86. 1. 2 24.8 2.7 13.4 306. 1000. 85. 2. 1 25.0 2.5 8.5 303. 1006. 86. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408241100 787935 **************************************************** PBO 2408241100 FORECAST PROJECTION=77 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.8 7.8 2.3 80. 104. 28. 0. 43 -75.4 8.0 8.5 178. 112. 28. 1. 42 -74.4 7.3 15.8 185. 120. 32. 1. 41 -72.0 8.7 19.4 184. 129. 26. 1. 40 -68.5 11.9 19.9 165. 139. 17. 2. 39 -65.2 14.1 17.7 138. 150. 13. 2. 38 -62.7 11.5 27.0 109. 161. 20. 2. 37 -60.4 7.2 35.9 93. 173. 38. 3. 36 -57.5 6.6 35.7 83. 186. 42. 3. 35 -54.1 5.7 31.3 68. 199. 50. 4. 34 -50.1 6.9 27.4 56. 213. 44. 4. 33 -46.3 7.3 25.7 50. 229. 43. 4. 32 -42.4 9.5 26.8 49. 244. 34. 4. 31 -38.5 9.6 27.0 55. 261. 36. 4. 30 -35.2 8.0 19.6 74. 278. 44. 3. 29 -31.8 5.7 15.4 104. 297. 57. 2. 28 -28.1 4.8 14.5 109. 316. 63. 1. 27 -24.6 3.8 15.6 101. 337. 71. -0. 26 -21.3 3.9 13.3 96. 358. 71. -0. 25 -17.9 5.8 7.3 115. 380. 61. 2. 24 -14.5 6.2 9.9 140. 404. 59. 4. 23 -11.5 5.1 12.9 136. 428. 66. 6. 22 -9.0 4.2 12.9 130. 454. 71. 8. 21 -6.3 5.0 10.7 122. 481. 68. 10. 20 -3.4 5.7 9.3 109. 510. 65. 12. 19 -0.9 4.8 8.9 107. 540. 70. 13. 18 0.9 3.0 6.5 113. 571. 80. 13. 17 3.0 2.3 2.8 119. 603. 85. 11. 16 5.6 2.6 2.9 52. 637. 83. 9. 15 8.4 3.3 7.0 34. 673. 80. 5. 14 10.8 3.2 9.4 17. 710. 81. 2. 13 12.4 1.5 10.3 5. 749. 90. 2. 12 14.2 0.8 9.0 347. 790. 95. 3. 11 15.6 0.7 7.5 321. 822. 96. 3. 10 16.8 1.2 9.1 301. 845. 93. 2. 9 18.3 2.0 11.9 293. 867. 88. 2. 8 19.5 1.7 13.1 295. 889. 90. 3. 7 20.7 1.2 12.6 299. 914. 93. 2. 6 21.9 1.4 15.6 300. 938. 92. 3. 5 23.0 2.1 20.3 304. 959. 88. 4. 4 23.8 2.5 22.1 306. 976. 86. 3. 3 24.3 2.3 18.7 298. 989. 87. 2. 2 24.7 2.7 15.5 287. 1000. 85. 1. 1 25.1 2.7 13.0 283. 1005. 85. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408241200 787935 **************************************************** PBO 2408241200 FORECAST PROJECTION=78 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.0 7.4 3.1 224. 104. 30. -1. 43 -75.3 8.2 7.8 212. 112. 27. -2. 42 -74.0 8.1 11.3 203. 120. 28. -3. 41 -71.8 9.3 14.5 195. 129. 24. -4. 40 -68.5 12.8 15.6 187. 139. 14. -5. 39 -64.9 15.2 13.1 155. 150. 11. -5. 38 -62.2 11.5 18.9 109. 161. 20. -5. 37 -59.7 7.8 30.5 88. 173. 35. -5. 36 -56.9 4.5 41.6 87. 186. 56. -6. 35 -53.5 6.8 42.7 81. 199. 43. -5. 34 -49.5 11.6 35.7 76. 214. 24. -3. 33 -46.0 11.6 29.5 70. 229. 26. -1. 32 -42.1 10.8 27.8 62. 244. 30. -0. 31 -38.6 6.5 25.2 64. 261. 50. -1. 30 -35.2 5.3 20.9 79. 279. 58. -1. 29 -31.6 6.4 16.1 103. 297. 53. -0. 28 -27.9 7.3 14.0 128. 316. 50. 0. 27 -24.3 6.5 13.1 133. 337. 55. -1. 26 -21.3 4.5 11.5 123. 358. 67. -3. 25 -18.3 4.6 8.2 126. 380. 67. -5. 24 -15.1 4.1 10.8 125. 404. 71. -6. 23 -12.3 3.0 13.3 113. 429. 78. -7. 22 -9.7 2.9 12.2 106. 454. 79. -8. 21 -6.9 3.6 10.0 99. 482. 75. -9. 20 -4.2 3.8 8.9 95. 510. 75. -11. 19 -1.7 3.0 8.5 98. 540. 80. -11. 18 0.6 2.3 6.1 101. 571. 84. -10. 17 3.1 2.5 1.7 103. 603. 84. -8. 16 5.7 2.9 1.1 25. 638. 82. -6. 15 8.2 2.8 4.2 18. 673. 82. -6. 14 10.4 2.1 8.1 10. 711. 87. -4. 13 12.6 1.4 10.4 1. 750. 91. -1. 12 14.8 1.5 9.9 347. 791. 91. -0. 11 16.4 1.9 9.2 333. 823. 88. -2. 10 17.5 2.1 10.8 319. 845. 87. -5. 9 18.7 2.3 12.3 315. 867. 86. -6. 8 19.8 2.0 12.6 320. 889. 88. -6. 7 21.0 1.5 13.4 322. 914. 91. -5. 6 22.5 2.5 16.5 320. 939. 86. -2. 5 23.7 3.4 19.6 321. 959. 81. 0. 4 24.4 3.6 20.2 323. 976. 80. 2. 3 24.7 2.8 18.8 317. 989. 84. 3. 2 24.8 3.0 14.9 310. 1000. 83. 3. 1 24.8 2.5 9.3 310. 1006. 86. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408241300 787935 **************************************************** PBO 2408241300 FORECAST PROJECTION=79 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.4 8.2 7.3 244. 104. 26. -1. 43 -74.6 8.8 8.9 227. 112. 25. -1. 42 -73.7 8.7 11.5 198. 120. 26. -2. 41 -72.3 9.9 17.6 183. 129. 21. -3. 40 -69.2 12.5 18.8 176. 139. 15. -4. 39 -65.9 8.8 15.5 145. 150. 28. -4. 38 -63.6 4.7 21.4 105. 161. 53. -6. 37 -61.7 4.6 35.8 83. 173. 54. -9. 36 -58.5 4.5 44.4 71. 186. 56. -11. 35 -54.2 4.4 47.2 65. 199. 58. -11. 34 -50.0 4.3 46.1 59. 214. 61. -9. 33 -46.0 6.0 45.0 59. 229. 51. -6. 32 -42.2 7.3 39.8 62. 244. 45. -4. 31 -38.6 6.0 30.9 68. 261. 53. -3. 30 -35.3 3.5 22.7 75. 279. 70. -3. 29 -32.0 3.4 19.0 86. 297. 72. -5. 28 -28.2 5.2 13.6 109. 316. 61. -6. 27 -24.8 4.5 11.0 121. 337. 66. -6. 26 -21.8 3.1 9.7 108. 358. 76. -3. 25 -18.7 2.6 10.9 97. 381. 80. -0. 24 -15.5 2.9 15.1 97. 404. 78. 2. 23 -12.2 3.8 16.5 96. 429. 73. 3. 22 -9.1 4.0 14.4 92. 455. 73. 4. 21 -6.3 3.9 10.9 94. 482. 74. 5. 20 -3.6 4.5 6.6 106. 510. 71. 8. 19 -1.3 3.5 5.1 125. 540. 77. 12. 18 0.7 2.4 3.8 148. 571. 84. 15. 17 2.9 2.2 2.7 188. 604. 86. 18. 16 5.3 1.9 0.8 233. 638. 88. 22. 15 7.5 1.0 4.4 359. 674. 93. 25. 14 9.6 0.0 10.7 358. 711. 100. 24. 13 12.0 0.2 11.5 1. 750. 99. 21. 12 14.4 0.7 10.2 356. 791. 96. 17. 11 16.1 1.1 9.2 342. 823. 93. 12. 10 17.3 1.7 9.6 330. 845. 90. 7. 9 18.6 1.7 11.2 324. 868. 90. 3. 8 19.9 1.7 12.9 322. 890. 90. -1. 7 21.5 2.6 14.2 316. 915. 85. -4. 6 23.1 3.8 15.2 313. 939. 79. -5. 5 23.8 3.2 15.1 317. 960. 82. -5. 4 23.9 2.0 15.5 315. 977. 89. -4. 3 24.3 2.2 14.9 303. 990. 87. -2. 2 24.9 3.0 11.9 291. 1001. 83. -0. 1 25.3 3.2 10.7 290. 1006. 82. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408241400 787935 **************************************************** PBO 2408241400 FORECAST PROJECTION=80 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.8 8.0 8.8 180. 104. 27. -0. 43 -75.0 8.6 10.0 176. 112. 25. -3. 42 -73.5 9.2 11.7 163. 120. 24. -6. 41 -71.6 11.0 16.0 152. 129. 18. -10. 40 -69.0 12.5 19.4 146. 139. 15. -16. 39 -65.4 9.9 21.8 130. 150. 24. -17. 38 -62.3 5.9 30.3 98. 161. 45. -8. 37 -60.1 4.6 42.2 81. 173. 55. 6. 36 -56.9 4.5 44.7 73. 186. 56. 17. 35 -53.3 4.4 44.3 62. 199. 59. 18. 34 -49.6 4.3 40.1 55. 214. 61. 8. 33 -46.0 4.1 35.0 56. 229. 63. -8. 32 -42.2 3.9 28.2 61. 245. 65. -22. 31 -38.4 3.7 23.1 63. 261. 68. -31. 30 -34.8 3.5 19.4 68. 279. 71. -33. 29 -31.3 3.2 15.7 79. 297. 73. -28. 28 -27.9 3.0 12.7 100. 317. 76. -19. 27 -24.6 3.1 11.0 121. 337. 75. -11. 26 -21.2 3.5 9.6 131. 358. 73. -5. 25 -18.1 3.3 9.7 130. 381. 75. -2. 24 -15.4 3.0 13.7 128. 405. 78. -1. 23 -12.8 2.8 16.9 123. 429. 79. -1. 22 -9.8 1.6 15.6 108. 455. 88. -1. 21 -6.7 0.9 13.0 102. 482. 94. 4. 20 -4.6 1.7 4.6 136. 511. 88. 14. 19 -2.2 1.6 4.4 181. 541. 88. 22. 18 0.2 1.6 5.3 209. 572. 89. 25. 17 2.3 0.8 4.4 238. 605. 94. 22. 16 4.6 0.0 3.0 310. 639. 100. 18. 15 7.3 0.0 5.9 360. 675. 100. 16. 14 9.5 0.0 7.6 10. 712. 100. 18. 13 11.8 0.0 8.6 357. 751. 100. 19. 12 14.0 0.1 9.6 337. 792. 100. 18. 11 15.5 0.1 11.3 330. 824. 100. 15. 10 16.5 0.1 13.1 332. 846. 100. 13. 9 18.0 0.7 14.1 329. 869. 96. 12. 8 19.7 1.7 14.7 322. 891. 90. 13. 7 21.3 2.5 15.0 322. 916. 86. 12. 6 22.5 2.5 14.2 329. 941. 86. 11. 5 23.3 1.8 14.2 338. 961. 90. 8. 4 24.0 1.7 14.8 340. 978. 90. 6. 3 24.7 2.4 13.1 335. 991. 86. 5. 2 25.4 3.2 9.5 335. 1002. 83. 3. 1 25.9 3.5 7.5 336. 1008. 81. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1010. **************************************************** STATION = 9.35N 82.25W PBO 2408241500 787935 **************************************************** PBO 2408241500 FORECAST PROJECTION=81 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.2 7.6 3.1 153. 104. 29. 1. 43 -75.3 8.3 4.8 190. 112. 27. 2. 42 -73.8 9.1 10.6 179. 120. 24. 3. 41 -71.8 10.7 15.4 171. 129. 19. 2. 40 -69.0 10.6 19.8 157. 139. 20. 1. 39 -66.4 5.5 26.3 115. 150. 46. -0. 38 -64.3 4.7 47.4 85. 161. 53. -2. 37 -62.0 4.6 39.8 76. 173. 54. -3. 36 -58.1 4.5 29.2 67. 186. 56. -2. 35 -54.0 4.4 26.0 57. 199. 58. 0. 34 -50.0 4.3 25.0 53. 214. 61. 1. 33 -46.2 4.1 20.3 55. 229. 63. -4. 32 -42.4 3.9 18.7 62. 245. 65. -10. 31 -38.6 3.7 18.8 75. 261. 68. -10. 30 -34.9 3.5 18.6 93. 279. 71. -2. 29 -31.2 3.2 18.7 103. 297. 73. 6. 28 -27.6 2.9 18.1 104. 317. 76. 11. 27 -24.2 2.9 16.7 107. 337. 77. 14. 26 -21.2 2.7 15.8 114. 358. 79. 18. 25 -18.1 3.6 16.7 117. 381. 73. 19. 24 -14.9 5.2 18.6 113. 405. 65. 17. 23 -11.9 5.5 20.0 109. 429. 64. 13. 22 -9.2 4.1 18.3 109. 455. 72. 8. 21 -6.9 1.5 13.3 109. 482. 89. 4. 20 -4.4 0.8 8.3 112. 511. 94. -1. 19 -1.5 2.8 3.4 125. 541. 81. -4. 18 1.2 3.6 2.1 189. 572. 77. -4. 17 3.3 3.0 2.4 242. 604. 81. 2. 16 5.2 1.4 3.5 296. 639. 91. 9. 15 7.2 0.5 4.4 330. 674. 96. 13. 14 9.6 0.6 6.5 354. 712. 96. 13. 13 12.0 0.5 8.2 357. 751. 97. 8. 12 14.4 1.0 7.7 334. 792. 93. 3. 11 16.3 1.5 9.8 320. 824. 91. -0. 10 17.3 1.3 11.9 308. 846. 92. -0. 9 18.6 1.5 13.5 303. 869. 91. -1. 8 19.9 1.9 14.6 307. 891. 89. -1. 7 21.1 1.7 14.9 318. 916. 90. -1. 6 22.0 1.4 14.2 328. 940. 92. -1. 5 22.8 1.4 14.5 334. 961. 92. 1. 4 23.7 2.1 16.2 332. 978. 88. 3. 3 24.4 2.0 13.3 332. 991. 88. 4. 2 25.1 2.1 10.3 334. 1002. 88. 3. 1 25.7 2.4 8.2 335. 1008. 87. 2. PRCP(HR)=.021 PRCP(TOT)= 0.021 SFC PRES=1010. **************************************************** STATION = 9.35N 82.25W PBO 2408241600 787935 **************************************************** PBO 2408241600 FORECAST PROJECTION=82 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.8 8.0 4.8 318. 104. 27. 11. 43 -75.3 8.5 5.2 290. 112. 25. 30. 42 -73.7 9.3 5.6 249. 120. 23. 36. 41 -71.4 10.8 7.6 216. 129. 19. 31. 40 -68.4 11.3 11.7 185. 139. 18. 19. 39 -64.9 11.8 8.4 147. 150. 18. 6. 38 -62.4 9.2 18.6 92. 161. 28. -6. 37 -61.1 4.6 31.5 75. 173. 54. -13. 36 -58.3 4.5 34.5 60. 186. 56. -10. 35 -54.1 4.4 35.4 57. 199. 58. -5. 34 -50.0 4.3 34.6 53. 214. 61. 1. 33 -45.9 4.1 31.1 52. 229. 63. 4. 32 -42.1 3.9 26.5 54. 244. 66. 5. 31 -38.3 3.7 21.4 54. 261. 68. 5. 30 -34.7 3.4 13.5 50. 279. 71. 6. 29 -31.2 3.2 8.5 83. 297. 73. 7. 28 -27.8 2.9 13.0 111. 316. 76. 5. 27 -24.5 3.5 18.8 122. 337. 73. 4. 26 -21.0 5.4 17.8 127. 358. 62. 5. 25 -17.7 7.1 16.5 122. 381. 54. 6. 24 -14.6 8.1 17.2 113. 404. 50. 8. 23 -11.8 6.4 18.9 106. 429. 59. 10. 22 -9.0 4.1 15.6 99. 455. 72. 12. 21 -6.1 1.8 8.2 77. 482. 87. 14. 20 -3.5 1.4 6.0 74. 510. 90. 13. 19 -0.9 3.5 3.3 112. 540. 77. 11. 18 1.6 4.4 1.4 242. 571. 73. 8. 17 3.5 3.4 2.7 292. 604. 78. 3. 16 5.5 3.1 4.4 329. 638. 81. -3. 15 8.1 3.9 4.4 347. 674. 76. -8. 14 10.3 3.1 5.3 354. 711. 81. -12. 13 12.0 1.1 6.8 358. 750. 93. -13. 12 14.4 1.0 6.7 333. 791. 94. -11. 11 16.5 1.9 8.3 313. 823. 89. -10. 10 17.7 1.9 11.6 298. 845. 89. -7. 9 18.8 1.9 14.4 296. 868. 89. -5. 8 19.8 1.6 15.1 301. 890. 90. -3. 7 20.8 1.3 12.8 312. 915. 92. -2. 6 21.9 1.3 11.3 329. 939. 93. 0. 5 23.0 1.9 13.0 325. 960. 89. 4. 4 24.1 2.7 14.4 322. 977. 85. 6. 3 25.1 2.7 12.0 319. 990. 85. 6. 2 26.1 3.4 11.0 318. 1001. 82. 4. 1 26.8 3.8 9.9 317. 1006. 80. 2. PRCP(HR)=.002 PRCP(TOT)= 0.002 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408241700 787935 **************************************************** PBO 2408241700 FORECAST PROJECTION=83 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.0 6.2 6.5 302. 104. 36. -2. 43 -76.8 7.0 8.4 310. 112. 32. -7. 42 -74.5 8.7 5.4 240. 120. 25. -12. 41 -71.9 10.5 7.4 186. 129. 20. -15. 40 -68.6 11.0 10.8 131. 139. 19. -18. 39 -65.6 8.9 19.2 94. 150. 28. -21. 38 -63.5 6.1 24.5 78. 161. 43. -23. 37 -60.7 6.6 28.9 60. 173. 41. -17. 36 -57.5 8.5 37.9 55. 186. 33. -2. 35 -53.7 9.0 37.0 55. 199. 32. 15. 34 -49.8 8.3 33.0 55. 214. 37. 24. 33 -45.7 6.5 32.1 61. 229. 48. 21. 32 -41.5 6.6 32.1 70. 244. 49. 16. 31 -37.7 7.4 24.5 82. 261. 46. 13. 30 -33.8 6.0 20.6 78. 279. 55. 9. 29 -30.3 4.9 19.3 62. 297. 62. 1. 28 -26.8 5.4 9.8 48. 316. 60. -4. 27 -23.4 5.3 5.4 100. 337. 62. -7. 26 -20.4 3.9 16.2 118. 358. 71. -10. 25 -17.8 4.2 23.4 130. 380. 70. -12. 24 -14.8 5.0 22.2 140. 404. 65. -15. 23 -12.3 1.8 17.7 142. 429. 86. -19. 22 -9.9 1.2 10.3 142. 455. 91. -22. 21 -6.8 0.9 3.4 116. 482. 93. -24. 20 -4.2 0.8 2.9 109. 510. 94. -24. 19 -1.4 2.7 2.1 146. 540. 82. -21. 18 1.3 3.7 0.5 243. 571. 77. -18. 17 3.6 3.6 1.9 25. 604. 77. -13. 16 5.7 3.7 3.7 43. 638. 77. -8. 15 7.5 2.6 4.5 34. 673. 83. -4. 14 9.3 0.1 7.1 22. 711. 99. -2. 13 11.6 0.1 6.3 358. 750. 99. -1. 12 14.7 1.6 7.7 317. 791. 90. -3. 11 17.0 2.7 10.3 311. 823. 84. -3. 10 18.3 3.0 12.9 306. 845. 83. -0. 9 19.3 2.7 14.5 303. 867. 84. 4. 8 20.1 2.4 13.8 306. 890. 86. 7. 7 21.2 2.4 11.9 317. 914. 86. 10. 6 22.3 2.5 11.8 327. 939. 86. 9. 5 23.3 1.8 14.4 326. 960. 90. 7. 4 24.7 2.3 14.3 324. 976. 87. 4. 3 25.9 3.1 14.0 323. 990. 83. 3. 2 27.0 3.9 13.5 323. 1000. 79. 3. 1 27.7 4.4 12.4 322. 1006. 77. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408241800 787935 **************************************************** PBO 2408241800 FORECAST PROJECTION=84 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.3 5.9 17.0 186. 104. 38. 0. 43 -77.5 6.7 12.5 187. 112. 34. 2. 42 -75.2 8.2 11.9 178. 120. 27. 4. 41 -72.5 6.9 9.0 141. 129. 35. 5. 40 -70.0 4.9 11.6 63. 139. 48. 4. 39 -67.3 4.7 28.9 42. 150. 51. 1. 38 -64.1 4.7 36.2 43. 161. 53. -1. 37 -59.8 4.6 29.2 49. 173. 55. -1. 36 -56.5 4.5 27.6 60. 186. 57. 1. 35 -53.3 6.1 28.7 65. 199. 47. -0. 34 -49.8 4.9 27.2 72. 214. 57. -3. 33 -46.1 4.1 23.8 81. 229. 63. -6. 32 -42.2 3.9 22.2 87. 244. 65. -7. 31 -38.5 3.9 22.7 89. 261. 67. -6. 30 -34.5 6.5 22.0 89. 279. 52. -6. 29 -30.5 5.5 19.0 92. 297. 58. -7. 28 -26.9 4.3 13.8 107. 316. 67. -8. 27 -23.6 4.1 10.5 102. 337. 69. -8. 26 -20.6 5.0 14.8 100. 358. 64. -6. 25 -17.8 7.5 17.8 102. 381. 52. -4. 24 -14.8 5.9 17.7 102. 404. 61. -2. 23 -12.1 2.2 16.2 113. 429. 84. -4. 22 -9.9 0.7 12.9 141. 455. 95. -6. 21 -7.4 1.0 7.8 188. 482. 93. -3. 20 -4.5 1.3 6.1 208. 510. 91. 1. 19 -2.1 1.9 5.7 231. 540. 87. 0. 18 0.5 2.4 4.4 241. 571. 84. -3. 17 2.8 2.4 2.7 321. 604. 84. -5. 16 5.3 2.3 6.9 3. 638. 85. -1. 15 7.6 1.5 8.8 13. 674. 90. 7. 14 9.8 0.6 7.8 2. 711. 96. 16. 13 12.1 0.6 6.6 335. 750. 96. 24. 12 14.5 0.9 7.3 328. 791. 94. 26. 11 15.9 0.6 8.3 336. 823. 96. 21. 10 16.8 0.4 10.1 344. 846. 97. 15. 9 18.2 1.1 11.9 347. 868. 93. 10. 8 19.9 2.1 13.3 344. 890. 88. 11. 7 21.5 3.0 13.7 345. 915. 83. 13. 6 23.1 3.6 13.8 345. 939. 80. 16. 5 24.1 3.6 14.8 342. 960. 80. 15. 4 24.6 3.2 18.0 343. 977. 82. 13. 3 25.1 1.4 18.1 347. 990. 92. 10. 2 26.1 2.1 17.0 347. 1001. 88. 7. 1 26.9 2.7 14.6 347. 1007. 85. 4. PRCP(HR)=.001 PRCP(TOT)= 0.001 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408241900 787935 **************************************************** PBO 2408241900 FORECAST PROJECTION=85 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -79.1 5.4 20.3 169. 104. 41. 0. 43 -78.6 5.2 16.5 183. 112. 43. 1. 42 -76.0 6.5 15.3 171. 120. 36. 1. 41 -73.3 5.3 10.2 135. 129. 45. 1. 40 -70.2 5.3 12.1 64. 139. 46. 1. 39 -68.2 4.7 23.3 62. 149. 51. 1. 38 -64.9 4.7 25.1 54. 161. 52. -1. 37 -60.7 4.6 26.1 56. 173. 55. -3. 36 -57.1 4.5 29.0 66. 186. 56. -4. 35 -53.8 6.4 28.5 69. 199. 46. -5. 34 -50.1 8.8 26.5 74. 213. 35. -5. 33 -46.2 11.1 25.0 81. 228. 27. -5. 32 -42.2 13.6 24.9 90. 244. 21. -4. 31 -38.2 16.1 26.3 94. 261. 17. -3. 30 -34.1 17.4 27.1 95. 278. 15. -1. 29 -30.3 16.5 23.8 94. 297. 18. 1. 28 -26.9 11.6 17.4 93. 316. 33. 3. 27 -23.4 7.8 13.9 90. 336. 49. 3. 26 -20.5 7.0 16.1 95. 358. 54. 2. 25 -17.6 10.4 17.4 107. 380. 40. 2. 24 -14.6 11.3 17.4 110. 404. 38. 1. 23 -11.3 12.2 18.0 110. 428. 36. 0. 22 -8.1 9.6 19.0 101. 454. 46. 0. 21 -5.5 4.7 15.0 97. 481. 69. 0. 20 -3.2 4.5 4.4 141. 509. 71. -1. 19 -0.3 5.7 3.0 217. 539. 66. -5. 18 2.3 6.0 4.4 239. 570. 65. -11. 17 4.3 5.2 3.5 242. 603. 69. -17. 16 6.3 4.2 4.4 329. 637. 74. -19. 15 8.2 2.8 8.5 356. 673. 83. -15. 14 10.2 2.5 9.3 2. 710. 84. -9. 13 12.5 2.7 8.2 354. 749. 84. -3. 12 14.8 2.6 9.3 337. 790. 84. -2. 11 16.4 2.2 9.6 340. 822. 87. -4. 10 17.3 1.3 9.7 357. 844. 92. -7. 9 18.6 1.3 9.9 359. 866. 92. -8. 8 19.9 2.1 8.7 348. 888. 88. -9. 7 21.3 2.7 10.1 339. 913. 85. -9. 6 22.4 2.2 13.8 341. 938. 87. -9. 5 22.9 1.1 18.1 344. 958. 93. -9. 4 23.9 0.6 17.3 348. 975. 97. -7. 3 25.2 1.6 16.8 349. 988. 91. -3. 2 26.3 2.4 16.0 350. 999. 87. -0. 1 27.1 3.1 14.4 350. 1005. 83. 2. PRCP(HR)=.005 PRCP(TOT)= 0.005 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408242000 787935 **************************************************** PBO 2408242000 FORECAST PROJECTION=86 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.5 6.9 4.2 91. 104. 32. -2. 43 -76.5 7.7 1.5 110. 112. 29. -6. 42 -74.4 9.3 5.7 164. 120. 23. -10. 41 -71.7 10.7 9.9 163. 129. 19. -12. 40 -68.4 12.1 6.1 138. 139. 16. -14. 39 -65.9 9.3 10.1 64. 149. 26. -15. 38 -64.7 4.7 20.1 69. 161. 52. -16. 37 -61.5 4.6 26.1 74. 173. 54. -16. 36 -57.6 4.5 27.3 74. 186. 56. -13. 35 -53.7 4.4 26.4 77. 199. 58. -9. 34 -49.8 4.3 24.7 82. 213. 61. -5. 33 -45.6 4.1 23.5 88. 228. 63. -2. 32 -41.6 3.9 26.7 94. 244. 66. 1. 31 -38.0 8.8 31.9 103. 261. 39. 5. 30 -33.9 14.4 31.6 110. 278. 22. 7. 29 -29.9 14.6 28.8 111. 297. 23. 7. 28 -26.4 13.9 22.0 110. 316. 26. 6. 27 -22.9 13.2 14.7 106. 336. 29. 4. 26 -19.7 12.2 11.1 104. 358. 33. 1. 25 -16.6 13.4 11.6 116. 380. 30. -2. 24 -13.7 13.3 13.9 124. 403. 32. -5. 23 -11.1 11.5 15.1 120. 428. 38. -7. 22 -8.8 8.2 14.8 105. 454. 52. -9. 21 -5.7 5.1 11.4 92. 481. 67. -9. 20 -3.5 3.9 2.5 122. 509. 74. -8. 19 -1.3 3.7 2.4 256. 539. 76. -7. 18 0.4 2.2 4.6 309. 570. 85. -6. 17 2.8 1.7 8.3 332. 603. 88. -3. 16 5.4 1.7 8.9 4. 637. 89. 2. 15 7.8 1.7 10.3 18. 672. 89. 7. 14 10.2 2.0 9.0 26. 710. 87. 10. 13 12.8 3.1 8.0 23. 749. 81. 10. 12 15.0 3.0 8.7 12. 789. 82. 8. 11 16.2 1.8 10.9 3. 821. 89. 5. 10 17.5 2.4 13.3 356. 843. 86. 1. 9 19.2 3.9 13.5 356. 866. 78. -2. 8 20.6 4.1 11.9 354. 888. 78. -6. 7 21.8 2.9 10.5 347. 912. 83. -11. 6 22.5 2.0 11.3 337. 937. 88. -15. 5 23.0 1.4 11.8 331. 958. 92. -16. 4 24.4 2.0 11.0 334. 974. 89. -13. 3 25.7 3.0 10.9 334. 988. 84. -8. 2 26.7 3.8 10.5 334. 998. 80. -4. 1 27.4 4.3 9.8 334. 1004. 77. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1006. **************************************************** STATION = 9.35N 82.25W PBO 2408242100 787935 **************************************************** PBO 2408242100 FORECAST PROJECTION=87 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.4 7.8 9.4 111. 104. 28. -1. 43 -74.1 9.9 3.0 136. 112. 21. -3. 42 -72.3 11.7 2.8 176. 120. 16. -6. 41 -71.8 9.4 8.9 146. 129. 24. -6. 40 -70.2 5.9 18.2 130. 139. 42. -2. 39 -67.7 4.7 18.3 118. 149. 51. 2. 38 -65.4 4.7 20.7 99. 161. 52. 4. 37 -62.0 4.6 21.5 90. 173. 54. 4. 36 -57.8 4.5 22.9 84. 186. 56. 3. 35 -53.5 4.4 24.8 80. 199. 58. 3. 34 -49.2 4.2 24.8 85. 213. 61. 3. 33 -45.6 4.1 25.4 94. 228. 63. 5. 32 -41.7 11.8 29.1 97. 244. 27. 6. 31 -37.8 12.9 29.3 103. 261. 25. 5. 30 -34.1 9.9 27.9 107. 278. 36. 5. 29 -30.5 8.0 24.8 107. 297. 45. 3. 28 -27.1 8.4 21.0 104. 316. 45. 3. 27 -23.8 10.0 17.1 102. 336. 39. 4. 26 -20.2 12.0 12.8 101. 358. 34. 6. 25 -16.9 12.9 13.1 104. 380. 32. 9. 24 -14.2 11.2 14.9 108. 403. 38. 10. 23 -11.7 8.5 16.8 104. 428. 49. 10. 22 -9.1 6.4 16.8 97. 454. 60. 9. 21 -6.5 4.5 14.0 85. 481. 70. 7. 20 -3.4 4.3 7.8 74. 509. 72. 5. 19 -0.9 4.2 3.4 6. 539. 73. 6. 18 1.3 3.1 8.4 340. 570. 80. 7. 17 4.0 3.3 10.4 352. 603. 79. 7. 16 6.3 3.2 12.2 9. 637. 80. 5. 15 8.2 2.2 12.3 22. 672. 86. 1. 14 10.1 1.3 11.4 26. 710. 92. -2. 13 12.0 0.7 9.1 17. 749. 95. -3. 12 14.8 3.6 11.2 342. 789. 79. -2. 11 16.6 4.7 13.3 337. 821. 74. -1. 10 17.5 4.4 14.2 330. 844. 75. -1. 9 18.8 4.7 13.9 324. 866. 74. 2. 8 20.2 4.5 11.1 319. 888. 75. 7. 7 21.6 4.1 9.8 320. 912. 77. 10. 6 22.7 3.6 9.7 324. 937. 80. 10. 5 23.4 2.9 11.1 326. 958. 84. 9. 4 24.3 1.9 11.9 325. 974. 89. 8. 3 25.5 2.6 11.3 326. 988. 86. 6. 2 26.5 3.3 10.7 326. 998. 82. 4. 1 27.1 3.7 9.7 325. 1004. 80. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1006. **************************************************** STATION = 9.35N 82.25W PBO 2408242200 787935 **************************************************** PBO 2408242200 FORECAST PROJECTION=88 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.1 7.3 3.7 249. 104. 30. 3. 43 -77.0 6.6 1.4 349. 112. 34. 10. 42 -77.1 4.8 14.6 94. 120. 47. 12. 41 -74.7 4.7 27.6 101. 129. 48. 11. 40 -71.1 4.7 27.7 102. 139. 49. 8. 39 -67.6 4.7 24.1 96. 149. 51. 6. 38 -64.2 5.6 23.4 84. 161. 46. 4. 37 -60.4 7.7 23.7 73. 173. 36. 3. 36 -56.5 9.9 23.8 72. 186. 27. 0. 35 -52.7 11.0 23.5 76. 199. 25. -4. 34 -49.0 9.7 22.7 80. 213. 31. -9. 33 -45.2 10.5 23.6 83. 228. 30. -14. 32 -41.3 17.4 26.6 89. 244. 13. -17. 31 -37.2 21.6 29.1 98. 261. 9. -20. 30 -33.4 15.6 29.7 103. 278. 19. -21. 29 -29.9 10.5 27.2 104. 297. 35. -21. 28 -26.6 8.3 23.5 101. 316. 45. -19. 27 -23.2 9.2 19.9 99. 336. 43. -16. 26 -20.0 11.2 15.7 99. 358. 36. -12. 25 -16.7 12.8 13.1 101. 380. 32. -10. 24 -13.7 12.5 14.1 99. 403. 34. -10. 23 -11.1 10.4 15.8 90. 428. 42. -12. 22 -8.9 7.0 16.8 75. 454. 57. -11. 21 -6.5 4.9 15.4 70. 481. 68. -9. 20 -3.3 4.7 9.0 61. 509. 70. -6. 19 -0.3 4.3 6.7 348. 539. 73. -2. 18 1.8 3.0 9.8 336. 570. 81. 1. 17 3.4 1.6 8.5 355. 603. 89. 4. 16 5.3 0.5 9.7 30. 637. 96. 6. 15 7.4 1.0 10.1 19. 672. 94. 7. 14 9.7 2.6 11.7 1. 710. 84. 5. 13 12.4 3.4 10.3 6. 749. 80. 3. 12 14.8 3.7 9.2 20. 789. 78. 3. 11 16.0 1.8 11.2 40. 821. 89. 3. 10 17.0 0.8 11.5 41. 844. 95. 3. 9 18.3 1.3 10.6 37. 866. 92. 2. 8 19.8 2.7 9.0 28. 888. 85. 1. 7 21.5 4.1 8.6 0. 913. 77. -0. 6 23.2 5.1 9.9 319. 937. 73. 0. 5 24.4 4.9 9.6 311. 958. 74. 1. 4 25.1 4.6 9.0 320. 974. 76. 1. 3 25.7 2.7 7.0 327. 988. 85. -0. 2 26.7 3.4 6.8 326. 998. 81. 0. 1 27.3 3.9 6.3 326. 1004. 79. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1006. **************************************************** STATION = 9.35N 82.25W PBO 2408242300 787935 **************************************************** PBO 2408242300 FORECAST PROJECTION=89 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.1 7.5 2.3 265. 104. 29. 0. 43 -75.3 8.9 3.0 351. 112. 24. 1. 42 -74.7 8.0 9.1 86. 120. 28. 2. 41 -75.0 4.7 19.9 88. 129. 48. 2. 40 -72.0 4.7 26.9 93. 139. 49. 1. 39 -68.0 4.7 28.9 96. 149. 51. -0. 38 -64.2 4.6 29.2 96. 161. 53. 0. 37 -60.4 4.6 27.5 92. 173. 55. 2. 36 -56.7 7.2 25.6 88. 186. 40. 4. 35 -52.9 9.3 25.1 88. 199. 31. 5. 34 -49.1 11.1 25.2 90. 213. 26. 6. 33 -45.1 14.4 26.2 94. 228. 18. 7. 32 -40.9 19.7 28.0 98. 244. 10. 8. 31 -36.8 24.4 28.6 101. 261. 6. 8. 30 -33.5 14.6 26.7 102. 278. 22. 8. 29 -30.5 7.2 23.6 104. 297. 49. 8. 28 -27.0 5.8 21.2 103. 316. 58. 8. 27 -23.4 7.5 20.3 98. 336. 50. 8. 26 -20.0 9.8 18.9 90. 358. 41. 7. 25 -17.1 10.3 16.1 82. 380. 40. 5. 24 -14.4 8.6 15.7 74. 403. 48. 3. 23 -11.8 6.5 18.4 73. 428. 58. 1. 22 -9.4 4.3 20.1 72. 454. 71. 2. 21 -7.2 1.5 16.6 70. 481. 89. 4. 20 -4.2 1.7 7.7 66. 509. 88. 5. 19 -0.5 3.0 5.0 352. 539. 80. 4. 18 1.4 1.7 6.9 357. 570. 89. 1. 17 3.4 0.9 9.6 20. 603. 94. -1. 16 5.8 1.6 11.1 12. 637. 89. -3. 15 7.8 1.7 12.0 6. 673. 89. -6. 14 9.8 1.4 13.0 19. 710. 91. -9. 13 12.2 1.6 13.1 30. 749. 90. -13. 12 14.7 2.1 10.8 38. 790. 88. -14. 11 16.5 2.0 9.0 29. 822. 88. -14. 10 17.7 2.4 10.4 360. 844. 86. -14. 9 18.6 1.5 12.7 347. 866. 91. -14. 8 19.6 0.5 13.3 349. 888. 97. -14. 7 21.2 1.2 13.1 352. 913. 93. -12. 6 23.3 4.0 13.1 351. 938. 78. -7. 5 25.0 6.4 12.7 342. 958. 68. -2. 4 25.9 6.7 12.0 329. 975. 66. 2. 3 26.1 5.1 12.0 324. 988. 74. 4. 2 26.2 3.1 9.6 329. 999. 83. 4. 1 26.7 3.2 8.2 331. 1004. 83. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408250000 787935 **************************************************** PBO 2408250000 FORECAST PROJECTION=90 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.7 7.7 7.5 305. 104. 28. -1. 43 -74.7 9.7 4.6 291. 112. 21. -2. 42 -73.0 10.2 1.6 44. 120. 20. -2. 41 -73.5 6.4 11.0 63. 129. 37. -1. 40 -71.9 5.1 20.2 82. 139. 46. 5. 39 -68.8 5.0 23.8 88. 149. 48. 13. 38 -65.3 5.0 28.1 86. 161. 50. 20. 37 -61.8 4.6 30.3 86. 173. 54. 23. 36 -58.0 4.5 30.4 90. 186. 56. 19. 35 -53.7 4.4 30.9 97. 199. 58. 9. 34 -49.4 4.2 32.3 105. 213. 61. -1. 33 -45.2 4.1 32.9 109. 228. 63. -4. 32 -41.1 3.9 32.3 109. 244. 66. 1. 31 -37.4 3.6 30.8 102. 261. 69. 10. 30 -33.7 6.1 29.5 100. 278. 54. 15. 29 -30.0 8.6 27.2 99. 297. 43. 13. 28 -26.8 7.0 21.7 91. 316. 51. 10. 27 -23.9 5.8 16.3 73. 336. 59. 7. 26 -20.8 7.4 15.6 64. 358. 52. 5. 25 -17.8 7.8 16.0 64. 380. 51. 4. 24 -15.0 6.8 17.1 68. 404. 56. 4. 23 -12.2 5.4 18.8 74. 428. 64. 3. 22 -9.5 4.2 19.4 78. 454. 72. 2. 21 -6.9 2.8 17.3 78. 481. 80. 0. 20 -4.0 1.8 12.6 69. 510. 87. -1. 19 -0.5 3.4 7.9 55. 539. 78. -4. 18 2.1 3.1 8.6 42. 571. 80. -9. 17 3.9 2.1 12.1 30. 603. 86. -14. 16 5.6 1.4 13.9 31. 637. 91. -15. 15 7.3 0.9 13.9 39. 673. 94. -13. 14 9.2 0.2 13.5 42. 710. 98. -11. 13 11.4 0.2 12.2 39. 749. 99. -9. 12 14.0 0.7 9.2 35. 790. 95. -8. 11 15.7 0.5 6.4 10. 822. 97. -7. 10 17.0 0.0 9.5 341. 844. 100. -6. 9 18.2 0.0 10.1 330. 867. 100. -6. 8 19.9 1.8 10.7 320. 889. 89. -6. 7 22.0 4.1 11.0 326. 914. 77. -6. 6 23.8 5.8 11.4 326. 938. 70. -7. 5 25.0 6.3 11.2 323. 959. 68. -6. 4 25.8 6.1 10.7 320. 975. 69. -4. 3 26.2 5.4 10.8 322. 989. 72. -2. 2 26.2 3.0 9.3 328. 999. 83. 0. 1 26.4 2.5 6.3 330. 1005. 86. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408250100 787935 **************************************************** PBO 2408250100 FORECAST PROJECTION=91 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.6 7.4 6.1 313. 104. 30. 0. 43 -74.2 10.4 4.4 345. 112. 19. 3. 42 -72.9 10.5 9.5 39. 120. 19. 6. 41 -72.8 7.8 20.1 55. 129. 30. 9. 40 -71.4 6.6 28.3 66. 139. 37. 9. 39 -68.6 6.4 29.8 73. 150. 39. 7. 38 -65.4 4.9 25.7 82. 161. 50. 4. 37 -61.8 4.6 24.0 95. 173. 54. 1. 36 -57.8 4.5 24.1 105. 186. 56. -2. 35 -53.8 4.4 23.3 113. 199. 58. -3. 34 -49.8 4.3 21.0 124. 214. 61. -2. 33 -45.6 4.1 19.0 130. 229. 63. 0. 32 -41.4 4.8 20.6 123. 244. 59. 2. 31 -37.4 6.4 21.6 112. 261. 51. 2. 30 -33.4 6.5 21.0 104. 279. 52. 2. 29 -30.0 4.0 23.3 98. 297. 68. 1. 28 -27.0 3.1 24.8 93. 316. 75. 1. 27 -23.9 5.0 19.6 84. 337. 63. 2. 26 -20.8 6.9 14.9 74. 358. 54. 3. 25 -17.7 7.9 13.3 73. 380. 50. 3. 24 -14.8 7.3 13.7 78. 404. 54. 3. 23 -12.1 5.4 16.0 82. 429. 64. -0. 22 -9.7 3.4 18.5 83. 455. 76. -4. 21 -7.2 2.1 19.2 82. 482. 85. -8. 20 -4.4 1.7 17.0 79. 510. 88. -7. 19 -1.4 1.5 13.3 71. 540. 90. -4. 18 1.1 1.0 12.3 64. 571. 93. -1. 17 2.8 0.1 13.7 57. 604. 100. 1. 16 4.8 0.0 15.3 50. 638. 100. 2. 15 7.0 0.0 14.1 50. 674. 100. 3. 14 9.3 0.0 13.0 48. 711. 100. 3. 13 11.7 0.0 11.9 37. 750. 100. 2. 12 14.0 0.5 8.0 26. 791. 97. -1. 11 15.9 0.6 6.1 9. 823. 96. -3. 10 17.1 0.4 6.5 335. 845. 97. -5. 9 18.9 2.7 9.8 311. 868. 84. -5. 8 20.3 4.1 11.7 299. 890. 77. -5. 7 21.9 4.7 11.1 298. 914. 75. -4. 6 23.6 5.6 11.1 304. 939. 71. -3. 5 24.8 5.9 11.6 312. 960. 70. -1. 4 25.6 5.3 12.1 321. 976. 73. -0. 3 25.9 3.5 12.0 327. 990. 81. 1. 2 26.3 2.5 9.1 329. 1000. 86. 1. 1 26.5 2.4 5.5 330. 1006. 87. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408250200 787935 **************************************************** PBO 2408250200 FORECAST PROJECTION=92 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.4 6.7 0.9 257. 104. 34. -1. 43 -76.7 7.5 4.9 195. 112. 30. -3. 42 -74.5 8.0 6.2 86. 120. 28. 0. 41 -72.9 7.4 19.0 76. 129. 32. 7. 40 -71.7 5.5 31.6 82. 139. 43. 14. 39 -68.9 4.9 37.6 81. 150. 49. 17. 38 -65.1 6.3 32.9 80. 161. 41. 15. 37 -62.2 4.6 19.2 95. 173. 54. 10. 36 -58.5 4.5 14.9 109. 186. 56. 1. 35 -54.1 4.4 13.7 116. 199. 58. -8. 34 -49.9 4.3 13.9 126. 214. 61. -12. 33 -45.9 4.1 14.4 129. 229. 63. -9. 32 -41.9 3.9 14.7 127. 244. 66. -2. 31 -38.0 3.7 15.8 118. 261. 68. 4. 30 -34.1 3.4 20.0 110. 279. 71. 9. 29 -30.6 3.2 23.5 105. 297. 74. 11. 28 -27.0 3.2 21.6 98. 316. 74. 10. 27 -23.7 3.3 18.8 86. 337. 74. 8. 26 -20.9 5.0 16.3 71. 358. 64. 7. 25 -17.9 5.7 15.7 68. 381. 61. 9. 24 -14.9 5.2 17.6 74. 404. 64. 9. 23 -11.8 4.5 20.7 78. 429. 69. 8. 22 -8.9 4.0 23.0 78. 455. 73. 6. 21 -6.2 3.8 22.8 77. 482. 74. 5. 20 -3.7 3.3 20.2 77. 510. 78. 4. 19 -1.3 2.3 17.0 74. 540. 84. 5. 18 1.3 1.6 13.8 71. 571. 89. 6. 17 3.3 1.0 13.3 71. 604. 93. 6. 16 5.2 0.8 14.5 73. 638. 95. 9. 15 7.4 0.7 14.6 72. 674. 95. 13. 14 9.8 1.1 12.3 68. 711. 93. 12. 13 12.4 1.7 10.4 56. 750. 89. 4. 12 14.6 1.4 9.6 36. 791. 91. -8. 11 16.0 0.6 7.7 27. 823. 96. -14. 10 17.3 1.0 3.2 334. 845. 94. -14. 9 18.9 2.8 9.1 285. 868. 84. -11. 8 20.1 3.2 12.8 285. 890. 82. -8. 7 21.5 3.2 13.8 288. 914. 82. -4. 6 22.9 3.5 14.4 296. 939. 81. -3. 5 24.0 3.4 15.3 306. 960. 82. -4. 4 24.6 2.7 16.0 315. 976. 85. -6. 3 25.2 1.8 15.7 320. 990. 90. -5. 2 25.8 1.5 13.5 321. 1000. 92. -2. 1 26.3 1.5 9.6 317. 1006. 91. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408250300 787935 **************************************************** PBO 2408250300 FORECAST PROJECTION=93 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -79.3 5.0 15.5 101. 104. 44. -0. 43 -79.7 4.7 12.1 140. 112. 46. -1. 42 -75.6 6.5 12.1 142. 120. 36. 0. 41 -72.0 9.1 13.1 134. 129. 24. 4. 40 -69.6 10.3 12.9 102. 139. 21. 9. 39 -67.7 8.6 16.3 83. 150. 28. 12. 38 -65.1 6.6 20.5 77. 161. 40. 12. 37 -61.9 5.1 23.9 91. 173. 50. 8. 36 -58.5 4.5 25.6 97. 186. 56. 6. 35 -54.2 5.5 20.5 102. 199. 51. 10. 34 -50.5 4.9 13.5 128. 214. 56. 19. 33 -46.3 4.8 14.8 140. 229. 58. 27. 32 -41.9 7.9 19.7 118. 244. 42. 27. 31 -37.4 11.4 24.9 107. 261. 30. 19. 30 -33.9 4.5 28.4 107. 279. 63. 7. 29 -30.9 3.2 24.2 109. 297. 73. -4. 28 -27.2 2.9 21.5 107. 316. 76. -12. 27 -23.9 2.5 20.4 104. 337. 80. -19. 26 -20.8 1.9 19.6 100. 358. 85. -21. 25 -17.8 1.4 18.9 96. 381. 89. -18. 24 -15.0 1.0 18.9 92. 404. 92. -13. 23 -12.3 1.0 19.5 89. 429. 92. -7. 22 -9.2 1.9 20.8 85. 455. 86. 0. 21 -6.3 2.6 23.5 81. 482. 82. 6. 20 -3.7 2.6 25.5 77. 510. 82. 9. 19 -1.2 2.8 22.3 76. 540. 81. 12. 18 1.4 2.5 16.5 78. 571. 83. 16. 17 3.5 1.1 15.3 92. 604. 92. 20. 16 5.9 0.3 15.2 95. 638. 98. 20. 15 7.9 0.0 10.9 78. 674. 100. 16. 14 9.8 0.0 7.9 60. 711. 100. 18. 13 11.9 0.0 8.7 42. 751. 100. 24. 12 14.3 0.7 7.3 4. 791. 96. 23. 11 16.0 0.7 7.2 324. 824. 96. 18. 10 17.3 1.2 7.8 314. 846. 93. 15. 9 19.0 2.3 9.0 309. 868. 86. 14. 8 20.1 2.6 11.7 304. 890. 85. 16. 7 21.1 2.3 13.3 306. 915. 87. 17. 6 22.3 2.5 14.1 310. 940. 86. 15. 5 23.5 2.8 14.2 311. 960. 84. 12. 4 24.4 3.1 13.5 306. 977. 83. 10. 3 25.1 2.7 12.0 300. 990. 85. 7. 2 25.7 2.4 10.0 295. 1001. 87. 4. 1 26.0 2.1 7.1 288. 1007. 88. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408250400 787935 **************************************************** PBO 2408250400 FORECAST PROJECTION=94 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.7 8.1 34.5 141. 104. 27. -0. 43 -74.6 10.0 29.2 146. 112. 20. 1. 42 -73.6 9.8 17.6 134. 120. 21. 1. 41 -72.0 9.9 5.1 75. 129. 21. 1. 40 -69.8 10.9 11.2 30. 139. 19. 0. 39 -68.4 6.8 11.5 57. 150. 37. 0. 38 -66.0 4.8 19.4 90. 161. 51. 1. 37 -62.8 4.7 28.2 98. 173. 53. 5. 36 -58.6 4.7 20.4 105. 186. 54. 13. 35 -54.6 6.3 14.5 130. 199. 46. 24. 34 -50.6 6.0 13.1 142. 214. 49. 34. 33 -46.6 4.8 13.0 139. 229. 58. 39. 32 -42.6 3.9 14.3 130. 244. 65. 38. 31 -38.5 4.3 17.0 122. 261. 64. 28. 30 -34.5 3.8 21.0 118. 279. 68. 10. 29 -30.6 3.1 25.1 115. 297. 74. -13. 28 -26.8 2.9 28.3 113. 316. 77. -32. 27 -23.4 2.4 30.5 111. 337. 81. -44. 26 -20.4 1.9 32.2 105. 358. 85. -47. 25 -17.6 1.4 33.7 96. 381. 89. -40. 24 -14.9 1.0 34.2 90. 404. 92. -30. 23 -12.1 1.1 33.6 85. 429. 92. -18. 22 -9.1 1.9 32.6 81. 455. 86. -5. 21 -6.3 2.3 32.0 80. 482. 84. 8. 20 -4.0 1.9 31.3 78. 510. 86. 19. 19 -1.8 1.6 29.4 75. 540. 89. 24. 18 0.7 1.9 25.9 71. 571. 87. 21. 17 3.2 1.5 22.9 69. 604. 90. 11. 16 5.2 0.7 19.2 72. 638. 95. 2. 15 7.4 1.7 9.9 78. 674. 89. -2. 14 9.6 0.4 7.3 110. 711. 98. -5. 13 12.3 0.0 7.4 57. 750. 100. -6. 12 14.1 0.2 9.0 11. 791. 98. 1. 11 16.2 1.1 8.9 346. 823. 93. 9. 10 17.4 1.1 8.3 324. 845. 93. 12. 9 18.7 1.6 9.4 316. 868. 90. 13. 8 19.9 2.1 12.7 298. 890. 88. 12. 7 21.1 1.7 14.2 295. 915. 90. 9. 6 22.3 1.6 13.6 301. 939. 91. 5. 5 23.1 1.6 12.9 302. 960. 91. 2. 4 23.8 1.5 13.0 301. 977. 91. 1. 3 24.4 1.3 12.6 298. 990. 92. 1. 2 24.9 1.0 9.7 288. 1001. 94. 1. 1 25.4 1.1 7.5 284. 1006. 94. 1. PRCP(HR)=.075 PRCP(TOT)= 0.075 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2408250500 787935 **************************************************** PBO 2408250500 FORECAST PROJECTION=95 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.7 5.9 27.8 168. 104. 38. -1. 43 -78.8 4.6 20.1 146. 112. 47. -3. 42 -76.5 5.0 16.2 117. 120. 45. -3. 41 -73.3 7.6 15.3 103. 129. 31. -2. 40 -70.1 10.1 11.3 83. 139. 22. -1. 39 -66.9 11.8 12.1 70. 150. 17. 0. 38 -63.9 12.6 19.6 69. 161. 16. 2. 37 -60.9 12.6 22.4 77. 173. 17. 3. 36 -58.1 9.5 21.9 92. 186. 29. 3. 35 -54.9 6.5 19.0 106. 199. 44. 2. 34 -50.8 4.3 13.9 117. 214. 60. 1. 33 -46.6 4.1 14.3 126. 229. 63. 0. 32 -42.4 4.0 18.4 119. 244. 65. 0. 31 -38.3 4.4 22.9 116. 261. 63. 1. 30 -34.5 3.6 24.0 113. 278. 69. 2. 29 -30.7 4.4 22.9 106. 297. 65. 3. 28 -27.3 3.7 23.2 108. 316. 71. 4. 27 -23.9 2.7 23.6 108. 337. 79. 3. 26 -20.8 2.2 22.9 101. 358. 83. 1. 25 -17.8 2.1 23.1 96. 380. 83. -2. 24 -14.6 2.9 24.5 95. 404. 78. -4. 23 -11.4 4.0 26.5 96. 429. 72. -5. 22 -8.7 3.9 27.4 98. 454. 73. -5. 21 -6.3 2.7 25.8 104. 482. 81. -5. 20 -3.8 1.9 23.9 111. 510. 86. -5. 19 -1.7 0.9 20.9 100. 540. 93. -6. 18 0.4 0.9 23.9 88. 571. 94. -5. 17 3.2 2.4 22.8 87. 604. 84. -1. 16 5.8 2.1 19.8 98. 638. 86. 3. 15 7.4 0.0 11.1 105. 673. 100. 3. 14 10.1 1.1 7.1 98. 711. 93. 1. 13 12.1 0.2 5.7 72. 750. 99. 2. 12 14.5 1.1 6.0 30. 791. 93. 2. 11 16.4 1.5 7.6 348. 823. 91. 0. 10 17.4 1.2 8.5 326. 845. 93. -2. 9 18.9 1.8 11.2 309. 867. 90. -3. 8 20.2 1.9 14.4 313. 890. 89. -3. 7 21.4 2.5 15.1 309. 914. 86. -2. 6 22.7 3.1 14.9 303. 939. 83. 0. 5 23.8 3.0 16.8 306. 960. 83. 2. 4 23.9 1.3 17.3 310. 976. 92. 2. 3 24.2 0.5 14.9 307. 989. 97. 1. 2 24.7 0.9 11.5 293. 1000. 95. 1. 1 25.2 1.2 10.0 291. 1006. 93. 1. PRCP(HR)=.008 PRCP(TOT)= 0.008 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408250600 787935 **************************************************** PBO 2408250600 FORECAST PROJECTION=96 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -79.7 4.7 18.5 164. 104. 46. -1. 43 -80.0 4.6 21.0 144. 112. 46. -2. 42 -76.8 4.7 26.0 142. 120. 48. -3. 41 -73.1 4.7 21.9 131. 129. 49. -4. 40 -70.0 9.7 12.9 99. 139. 23. -1. 39 -66.8 12.3 13.0 60. 149. 16. 2. 38 -63.5 13.0 16.9 53. 161. 16. 5. 37 -60.2 13.3 20.5 58. 173. 16. 5. 36 -57.2 12.0 22.6 69. 186. 20. 5. 35 -54.1 11.9 23.4 82. 199. 22. 5. 34 -50.5 11.6 20.5 92. 213. 24. 6. 33 -46.7 9.7 17.4 107. 228. 32. 7. 32 -42.6 7.9 17.9 122. 244. 42. 9. 31 -38.5 8.1 18.2 129. 261. 42. 11. 30 -34.2 9.6 18.9 132. 278. 37. 10. 29 -30.5 5.9 20.6 134. 297. 56. 6. 28 -27.5 2.9 21.2 124. 316. 76. 2. 27 -23.9 2.9 23.2 107. 336. 77. 1. 26 -20.7 3.3 26.6 96. 358. 75. -1. 25 -17.5 4.1 27.2 94. 380. 71. -3. 24 -14.3 5.1 25.3 95. 404. 65. -6. 23 -11.6 2.2 24.5 102. 428. 84. -9. 22 -9.0 0.4 23.8 100. 454. 97. -11. 21 -6.6 0.1 21.8 101. 481. 99. -9. 20 -4.2 0.4 23.7 116. 510. 97. -3. 19 -1.5 1.3 25.6 120. 540. 91. 1. 18 0.9 1.4 20.7 115. 571. 91. 1. 17 2.8 0.7 21.5 86. 603. 95. -1. 16 5.2 1.5 18.9 83. 638. 90. -1. 15 7.9 1.2 8.6 106. 673. 92. 1. 14 10.4 1.5 3.0 119. 711. 91. 3. 13 12.5 1.1 5.0 53. 750. 93. 2. 12 14.9 1.7 5.6 18. 790. 90. 2. 11 16.4 1.6 7.4 335. 822. 90. 1. 10 17.4 1.2 9.6 319. 845. 93. -2. 9 18.7 1.5 12.5 316. 867. 91. -5. 8 19.8 2.1 15.2 314. 889. 88. -8. 7 21.2 2.7 17.5 314. 914. 84. -9. 6 22.4 3.1 20.2 318. 938. 83. -8. 5 23.4 2.9 20.8 323. 959. 84. -4. 4 23.8 1.2 19.1 317. 976. 93. -1. 3 24.3 0.6 14.7 311. 989. 96. 0. 2 24.9 1.1 11.1 304. 1000. 94. 1. 1 25.2 1.2 7.5 298. 1005. 93. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408250700 787935 **************************************************** PBO 2408250700 FORECAST PROJECTION=97 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -79.6 4.7 16.3 156. 104. 46. -0. 43 -79.2 4.6 15.9 151. 112. 47. -1. 42 -76.9 4.7 18.5 145. 120. 47. 0. 41 -73.5 4.7 18.2 129. 129. 49. 1. 40 -70.3 7.2 18.5 92. 139. 34. -1. 39 -67.1 9.7 22.4 70. 149. 24. -3. 38 -63.3 11.4 24.8 72. 161. 20. -2. 37 -59.4 9.3 31.1 75. 173. 29. 1. 36 -55.9 11.2 32.4 76. 186. 23. 2. 35 -52.8 15.4 29.8 75. 199. 14. 0. 34 -49.9 12.0 23.6 79. 213. 23. -4. 33 -46.6 10.5 18.8 95. 228. 29. -9. 32 -42.4 12.0 17.6 109. 244. 26. -14. 31 -38.3 12.1 15.9 122. 261. 27. -15. 30 -34.3 9.9 14.7 134. 278. 36. -11. 29 -30.6 7.8 15.1 128. 297. 46. -3. 28 -26.9 7.9 18.2 110. 316. 47. 2. 27 -23.3 7.5 19.0 101. 336. 50. 2. 26 -20.3 6.6 19.0 90. 358. 56. 1. 25 -17.2 6.5 18.4 90. 380. 57. 1. 24 -14.2 6.6 18.2 99. 404. 57. 2. 23 -11.4 6.4 19.1 108. 428. 59. 4. 22 -8.6 6.0 20.2 112. 454. 62. 4. 21 -5.9 5.3 21.0 111. 481. 66. 3. 20 -3.3 4.5 21.5 111. 510. 71. 3. 19 -1.1 3.3 21.7 113. 539. 78. 1. 18 0.9 1.6 20.0 115. 570. 89. -2. 17 2.9 -0.0 14.3 105. 603. 100. -5. 16 5.1 0.4 16.2 85. 637. 97. -7. 15 7.4 0.9 10.2 76. 673. 94. -7. 14 10.0 0.8 2.2 95. 710. 95. -6. 13 12.2 0.6 4.6 26. 749. 96. -4. 12 14.4 1.1 7.5 5. 790. 93. -2. 11 15.8 0.7 8.2 339. 822. 96. -1. 10 17.0 0.8 11.0 323. 844. 95. -0. 9 18.2 1.1 14.9 311. 866. 93. 2. 8 19.2 1.4 19.0 308. 889. 91. 3. 7 20.8 1.9 19.1 312. 913. 89. 4. 6 22.7 3.0 19.1 316. 938. 83. 7. 5 23.3 2.1 21.4 319. 959. 88. 9. 4 23.4 0.4 22.3 317. 975. 97. 10. 3 23.9 0.3 19.5 309. 989. 98. 8. 2 24.5 0.8 14.9 301. 999. 95. 5. 1 24.9 1.1 11.7 299. 1005. 94. 2. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408250800 787935 **************************************************** PBO 2408250800 FORECAST PROJECTION=98 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -79.4 4.6 13.9 139. 104. 47. -1. 43 -79.9 4.7 9.5 168. 112. 46. -2. 42 -77.4 4.8 9.1 188. 120. 46. -1. 41 -73.9 4.8 5.7 208. 129. 48. 2. 40 -69.6 4.8 2.2 121. 139. 49. 3. 39 -65.3 8.3 3.7 93. 149. 31. 2. 38 -63.0 5.0 29.3 87. 161. 51. 3. 37 -61.1 4.6 34.4 81. 173. 54. 4. 36 -58.2 4.6 25.8 74. 186. 56. 5. 35 -54.3 4.4 20.9 79. 199. 58. 6. 34 -50.2 4.3 17.9 89. 213. 60. 7. 33 -46.4 4.1 13.6 102. 228. 63. 8. 32 -42.5 4.8 12.2 114. 244. 59. 9. 31 -38.3 8.0 12.6 105. 261. 43. 10. 30 -34.3 9.8 14.1 97. 278. 36. 10. 29 -30.6 9.3 14.8 94. 297. 40. 10. 28 -27.0 7.9 14.8 93. 316. 47. 8. 27 -23.6 7.7 19.0 81. 336. 49. 6. 26 -20.3 5.9 21.9 77. 358. 59. 3. 25 -17.4 3.3 20.1 79. 380. 75. 1. 24 -14.7 4.3 14.6 92. 404. 69. -0. 23 -11.9 4.5 15.9 114. 428. 69. 0. 22 -9.6 3.2 18.7 118. 454. 77. -2. 21 -7.8 0.9 21.2 122. 481. 93. -14. 20 -5.1 0.0 21.3 122. 510. 100. -42. 19 -1.7 0.0 14.6 118. 539. 100. -76. 18 0.5 0.0 8.4 106. 571. 100. -95. 17 2.7 0.0 7.2 85. 603. 100. -87. 16 4.9 0.0 8.2 68. 637. 100. -57. 15 7.3 0.0 7.9 55. 673. 100. -18. 14 9.6 0.0 8.1 33. 711. 100. 8. 13 11.9 0.6 9.4 30. 750. 96. 15. 12 14.2 1.0 9.0 16. 790. 94. 11. 11 15.8 0.8 9.3 351. 822. 95. 7. 10 17.3 1.3 9.9 336. 845. 92. 3. 9 18.7 1.9 12.5 318. 867. 89. -1. 8 19.9 2.3 15.3 318. 889. 87. -4. 7 21.4 3.1 16.7 322. 914. 82. -3. 6 22.9 3.7 18.6 322. 938. 80. -0. 5 23.5 2.8 20.3 323. 959. 84. 1. 4 23.3 0.4 19.0 319. 976. 98. 0. 3 24.1 0.4 16.0 315. 989. 98. -1. 2 24.9 1.0 13.8 312. 1000. 94. -0. 1 25.2 1.2 10.5 308. 1005. 93. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408250900 787935 **************************************************** PBO 2408250900 FORECAST PROJECTION=99 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -79.5 4.8 3.4 108. 104. 46. 5. 43 -78.2 6.2 4.2 151. 112. 36. 16. 42 -76.0 7.9 8.0 178. 120. 28. 25. 41 -73.2 10.0 9.2 184. 129. 21. 30. 40 -69.6 10.7 7.6 186. 139. 20. 30. 39 -65.7 9.1 7.6 169. 149. 27. 26. 38 -62.1 9.2 14.6 100. 161. 28. 20. 37 -59.9 8.2 32.4 80. 173. 34. 14. 36 -57.7 6.0 37.3 76. 186. 46. 12. 35 -54.4 5.1 29.5 74. 199. 53. 15. 34 -50.3 5.0 20.8 67. 213. 55. 21. 33 -46.4 4.9 15.3 85. 228. 57. 24. 32 -42.5 3.9 15.5 96. 244. 65. 20. 31 -38.4 3.7 15.8 89. 261. 68. 8. 30 -34.5 3.4 17.3 82. 278. 71. -2. 29 -30.7 3.2 18.6 78. 297. 74. -3. 28 -27.0 2.9 19.0 78. 316. 76. 1. 27 -23.5 2.6 18.3 80. 336. 79. 5. 26 -20.4 2.3 17.1 84. 358. 82. 7. 25 -17.6 2.2 17.3 95. 380. 83. 9. 24 -14.8 3.1 19.5 105. 404. 77. 10. 23 -11.8 3.0 21.6 105. 428. 78. 6. 22 -9.1 2.0 18.7 107. 454. 86. 0. 21 -6.8 2.1 14.2 114. 481. 85. -4. 20 -4.2 2.1 13.8 126. 510. 85. -3. 19 -1.9 1.9 12.6 133. 539. 87. 0. 18 -0.0 0.0 6.6 129. 571. 100. 2. 17 2.4 0.0 6.2 79. 603. 100. -1. 16 4.9 1.6 11.0 61. 637. 89. -8. 15 6.9 0.7 9.2 59. 673. 95. -14. 14 9.5 1.0 5.9 57. 710. 94. -18. 13 12.1 1.5 6.3 35. 749. 91. -17. 12 14.2 1.3 9.4 16. 790. 92. -17. 11 15.7 0.7 10.4 1. 822. 95. -17. 10 17.1 1.0 10.7 342. 844. 94. -16. 9 18.4 1.3 12.7 326. 867. 92. -14. 8 19.6 1.4 13.7 326. 889. 92. -10. 7 21.0 1.6 14.4 329. 913. 91. -4. 6 22.3 2.4 17.6 323. 938. 87. 2. 5 22.9 2.3 19.4 324. 959. 87. 4. 4 23.1 0.4 16.2 320. 975. 98. 1. 3 23.9 0.2 12.6 312. 989. 99. -1. 2 24.6 0.9 10.3 303. 999. 95. -2. 1 25.1 1.2 8.7 297. 1005. 93. -0. PRCP(HR)=.020 PRCP(TOT)= 0.020 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408251000 787935 **************************************************** PBO 2408251000 FORECAST PROJECTION=** LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -79.7 4.7 5.0 199. 104. 46. -1. 43 -78.4 6.5 4.9 217. 112. 35. -2. 42 -76.1 8.6 7.9 210. 120. 25. -2. 41 -73.4 9.0 10.5 214. 129. 24. -2. 40 -70.1 6.9 9.4 208. 139. 36. -2. 39 -67.1 5.1 9.4 112. 149. 48. -2. 38 -65.0 4.7 30.4 84. 161. 52. -3. 37 -62.0 4.8 33.2 75. 173. 53. -3. 36 -58.1 4.9 33.1 65. 186. 53. -1. 35 -54.1 4.9 32.0 65. 199. 55. 2. 34 -49.9 4.9 31.0 68. 213. 56. 5. 33 -45.7 5.2 29.2 73. 228. 56. 7. 32 -41.6 6.4 26.5 82. 244. 50. 9. 31 -37.6 8.1 22.3 90. 261. 42. 10. 30 -33.9 7.8 15.4 93. 278. 45. 10. 29 -30.6 5.6 11.1 97. 297. 58. 8. 28 -27.4 4.1 14.2 93. 316. 68. 6. 27 -23.8 5.7 19.3 84. 336. 59. 5. 26 -20.3 6.9 18.4 78. 358. 54. 4. 25 -17.1 4.9 16.6 82. 380. 66. 2. 24 -14.7 1.1 17.3 100. 404. 92. -6. 23 -11.9 0.5 19.4 89. 428. 96. -14. 22 -9.8 -0.0 19.5 79. 454. 100. -15. 21 -7.2 -0.0 15.0 72. 481. 100. -10. 20 -4.6 0.1 11.1 84. 510. 99. -1. 19 -2.3 0.2 10.3 85. 539. 98. 6. 18 0.7 1.3 8.3 104. 571. 91. 11. 17 2.6 1.4 4.9 80. 603. 91. 15. 16 5.6 2.7 11.3 66. 637. 83. 15. 15 7.8 2.0 13.5 59. 673. 87. 7. 14 9.8 1.4 10.9 33. 710. 91. 1. 13 12.1 1.6 9.7 15. 749. 90. -0. 12 14.4 1.7 9.6 4. 790. 90. -2. 11 16.2 1.6 9.1 354. 822. 90. -5. 10 17.3 1.6 8.6 335. 844. 90. -9. 9 18.7 1.8 9.6 317. 867. 89. -11. 8 20.0 2.1 10.3 312. 889. 88. -11. 7 21.5 3.0 11.7 310. 913. 83. -9. 6 22.9 3.8 13.7 315. 938. 79. -6. 5 23.3 2.7 14.9 323. 959. 85. -5. 4 23.4 0.5 14.7 321. 975. 97. -4. 3 24.0 0.4 12.9 310. 989. 98. -3. 2 24.5 1.0 10.7 296. 999. 94. -1. 1 24.9 1.3 9.1 293. 1005. 93. 0. PRCP(HR)=.006 PRCP(TOT)= 0.006 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2408251100 787935 **************************************************** PBO 2408251100 FORECAST PROJECTION=** LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.7 5.7 17.0 355. 104. 39. -2. 43 -77.5 7.4 2.0 181. 112. 30. -6. 42 -76.0 8.8 3.5 210. 120. 24. -9. 41 -73.3 7.9 4.0 233. 129. 29. -12. 40 -70.4 6.1 0.8 163. 139. 40. -13. 39 -67.4 5.4 10.8 77. 150. 47. -14. 38 -64.4 5.6 24.5 75. 161. 46. -12. 37 -61.0 6.1 34.0 80. 173. 44. -11. 36 -57.0 8.1 32.9 80. 186. 35. -9. 35 -53.3 11.0 30.7 76. 199. 25. -6. 34 -49.5 14.1 28.1 75. 214. 18. -2. 33 -45.9 13.2 23.6 83. 229. 21. 1. 32 -42.0 9.4 19.7 88. 244. 35. 3. 31 -37.7 12.5 15.2 108. 261. 26. 5. 30 -34.1 8.8 12.8 118. 279. 40. 6. 29 -30.6 6.2 11.8 115. 297. 55. 9. 28 -27.1 5.3 12.9 113. 316. 61. 10. 27 -23.7 4.8 14.8 106. 337. 65. 11. 26 -20.6 4.1 14.5 93. 358. 69. 12. 25 -17.6 3.7 11.2 85. 380. 73. 12. 24 -14.5 3.4 11.3 108. 404. 75. 12. 23 -11.8 4.5 17.8 121. 429. 69. 13. 22 -9.5 4.0 21.7 120. 454. 72. 11. 21 -7.1 2.4 23.1 118. 482. 83. 7. 20 -4.4 1.3 22.0 117. 510. 91. 3. 19 -1.8 0.7 16.0 105. 540. 95. 2. 18 0.2 0.6 12.7 91. 571. 96. 2. 17 2.2 0.7 12.7 76. 604. 95. 2. 16 4.8 1.0 13.7 58. 638. 93. 0. 15 7.2 0.9 14.5 43. 673. 94. -3. 14 9.3 0.5 13.7 24. 711. 97. -6. 13 11.6 0.0 11.8 6. 750. 100. -8. 12 14.0 0.0 9.5 351. 791. 100. -10. 11 15.6 0.0 8.5 329. 823. 100. -11. 10 16.5 0.0 9.1 321. 845. 100. -10. 9 17.9 0.8 10.7 312. 867. 95. -10. 8 19.3 1.7 14.0 311. 890. 90. -10. 7 20.7 2.1 16.1 318. 914. 88. -11. 6 21.8 1.8 17.2 329. 939. 89. -11. 5 22.7 1.6 18.4 329. 960. 91. -8. 4 23.4 1.1 16.5 320. 976. 94. -4. 3 24.0 0.8 14.7 308. 990. 95. -1. 2 24.5 1.5 12.8 294. 1000. 91. 0. 1 24.9 1.5 10.0 291. 1006. 91. 1. PRCP(HR)=.004 PRCP(TOT)= 0.004 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2408251200 787935 **************************************************** PBO 2408251200 FORECAST PROJECTION=** LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -79.5 5.3 12.7 342. 104. 42. -0. 43 -78.2 6.8 0.1 315. 112. 33. -0. 42 -76.5 6.4 7.1 158. 120. 36. 0. 41 -73.4 6.4 8.8 157. 129. 37. 1. 40 -70.2 6.1 7.5 112. 139. 41. -0. 39 -67.0 4.7 24.5 63. 150. 52. -3. 38 -63.0 6.4 23.0 66. 161. 42. -7. 37 -59.5 7.8 27.4 87. 173. 35. -10. 36 -56.4 9.0 37.2 86. 186. 31. -9. 35 -53.4 9.2 36.4 78. 199. 32. -8. 34 -50.1 7.1 30.2 74. 214. 43. -8. 33 -46.4 7.0 24.3 84. 229. 45. -11. 32 -42.4 6.9 18.8 100. 244. 47. -15. 31 -38.5 4.6 15.9 101. 261. 62. -16. 30 -34.8 3.5 17.1 99. 278. 71. -15. 29 -31.3 3.2 17.3 107. 297. 73. -10. 28 -27.6 2.9 17.2 119. 316. 76. -7. 27 -24.0 2.5 15.8 121. 337. 80. -5. 26 -21.0 1.9 14.0 115. 358. 84. -4. 25 -18.3 1.8 14.3 114. 380. 86. -2. 24 -15.0 4.3 18.0 118. 404. 70. 1. 23 -12.1 5.5 21.9 115. 429. 64. 4. 22 -9.4 5.0 24.3 110. 454. 67. 4. 21 -6.7 3.7 24.6 107. 482. 75. 2. 20 -4.0 3.5 20.3 107. 510. 77. 2. 19 -1.5 2.6 16.9 101. 540. 82. 4. 18 1.0 1.8 14.6 93. 571. 88. 7. 17 3.5 2.7 17.2 76. 603. 82. 7. 16 6.2 4.4 18.9 65. 638. 73. 2. 15 8.6 4.2 15.9 64. 673. 75. -3. 14 10.6 2.8 10.1 46. 711. 83. -8. 13 12.3 1.5 9.9 8. 750. 91. -13. 12 14.1 0.4 11.1 339. 790. 98. -16. 11 15.9 0.7 11.0 325. 822. 96. -18. 10 17.2 1.3 11.0 313. 845. 92. -18. 9 18.6 2.3 12.8 307. 867. 87. -16. 8 19.9 2.7 15.9 309. 889. 85. -13. 7 20.9 2.4 17.7 312. 914. 86. -11. 6 22.1 2.7 17.8 314. 939. 84. -8. 5 23.2 3.1 17.9 317. 959. 83. -6. 4 24.0 3.0 18.2 315. 976. 84. -4. 3 24.5 2.7 17.2 307. 989. 85. -2. 2 24.5 1.9 13.5 295. 1000. 89. -0. 1 24.9 1.9 10.8 292. 1005. 89. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. ****************************************************