STATION = 9.35N 82.25W PBO 2508260600 787935 **************************************************** PBO 2508260600 FORECAST PROJECTION= 0 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.9 7.5 12.3 146. 104. 29. 0. 43 -77.3 7.1 9.2 133. 112. 32. 0. 42 -76.0 6.8 8.6 92. 120. 34. 0. 41 -74.2 6.7 13.3 61. 129. 35. 0. 40 -71.7 6.4 19.5 51. 139. 38. 0. 39 -68.8 6.1 24.3 48. 150. 41. 0. 38 -65.4 5.6 26.4 50. 161. 46. 0. 37 -61.8 5.0 26.2 54. 173. 51. 0. 36 -57.9 4.5 24.9 60. 186. 56. 0. 35 -54.0 4.1 23.4 67. 199. 60. 0. 34 -50.2 3.9 22.2 74. 214. 63. 0. 33 -46.3 3.8 21.3 81. 229. 65. 0. 32 -42.4 3.7 20.5 87. 244. 67. 0. 31 -38.5 3.6 19.6 93. 261. 69. -0. 30 -34.6 3.4 19.1 98. 279. 71. -0. 29 -30.9 3.1 19.4 102. 297. 74. -0. 28 -27.3 2.8 20.8 102. 316. 77. -0. 27 -23.9 2.5 22.4 106. 337. 80. -0. 26 -20.7 2.4 23.8 118. 358. 81. -0. 25 -17.7 2.5 26.5 135. 381. 81. -0. 24 -14.9 2.5 28.7 144. 404. 81. -0. 23 -12.2 2.4 27.2 142. 429. 82. -0. 22 -9.5 2.1 22.7 134. 455. 85. -0. 21 -6.9 1.6 17.2 124. 482. 88. -0. 20 -4.2 1.3 14.7 107. 510. 91. -0. 19 -1.5 1.4 17.0 90. 540. 90. -0. 18 1.1 2.0 20.4 80. 571. 87. -0. 17 3.5 2.9 22.2 71. 604. 81. -0. 16 6.1 3.7 21.3 62. 638. 77. -0. 15 8.3 3.6 20.5 51. 674. 78. -0. 14 10.2 2.5 19.5 43. 711. 85. -0. 13 12.0 0.8 17.0 37. 750. 95. -0. 12 14.3 0.1 14.5 31. 791. 99. -0. 11 16.0 0.0 12.1 24. 823. 100. -0. 10 17.1 0.0 10.5 17. 846. 100. -0. 9 18.2 0.4 9.0 9. 868. 98. -0. 8 19.4 0.9 8.1 1. 890. 94. -0. 7 20.9 1.8 7.9 351. 915. 90. -0. 6 22.4 2.4 7.9 344. 940. 86. -0. 5 23.8 3.4 8.5 338. 960. 81. -0. 4 24.9 3.5 7.9 335. 977. 81. -0. 3 25.5 2.8 6.2 334. 990. 85. -0. 2 26.3 4.1 6.5 331. 1001. 78. -0. 1 26.8 4.0 6.4 330. 1007. 79. -0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2508261200 787935 **************************************************** PBO 2508261200 FORECAST PROJECTION= 6 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.2 8.0 15.7 245. 104. 27. -0. 43 -74.7 10.3 17.6 258. 112. 19. -1. 42 -72.2 12.2 16.3 265. 120. 15. -1. 41 -70.2 13.1 7.6 276. 129. 13. -1. 40 -69.1 11.2 7.5 66. 139. 18. -1. 39 -67.2 9.7 15.8 70. 149. 24. -1. 38 -64.2 10.9 21.7 69. 161. 21. -0. 37 -61.0 11.0 26.1 66. 173. 22. 0. 36 -57.5 9.5 27.9 64. 186. 29. 0. 35 -54.0 8.6 26.6 63. 199. 34. 0. 34 -50.3 8.0 23.4 61. 213. 38. -0. 33 -46.7 9.3 21.0 69. 228. 34. 0. 32 -43.5 7.5 22.7 86. 244. 43. 1. 31 -39.9 6.0 24.2 94. 261. 53. 1. 30 -36.2 4.3 23.6 103. 278. 64. 0. 29 -32.1 5.3 23.0 111. 297. 59. -0. 28 -28.6 3.7 22.1 113. 316. 70. -1. 27 -24.9 4.6 21.0 121. 336. 66. -1. 26 -21.8 2.6 19.8 136. 358. 79. -1. 25 -18.5 2.8 19.7 151. 380. 78. -0. 24 -15.2 3.6 20.6 159. 404. 74. 2. 23 -11.7 4.9 19.9 154. 428. 67. 4. 22 -8.1 6.5 18.2 136. 454. 59. 5. 21 -5.0 6.8 17.5 112. 481. 59. 6. 20 -2.7 4.3 18.2 88. 510. 72. 6. 19 -0.8 3.3 20.4 80. 539. 78. 5. 18 1.4 3.4 21.0 79. 570. 78. 4. 17 3.4 1.8 20.2 76. 603. 88. 2. 16 5.7 1.0 20.0 68. 637. 93. 1. 15 8.1 1.0 21.1 62. 673. 93. -0. 14 10.5 1.6 22.1 61. 710. 90. 0. 13 12.6 3.0 21.7 62. 749. 82. 1. 12 13.5 1.2 21.1 58. 790. 93. 5. 11 15.0 0.0 22.3 51. 822. 100. 8. 10 16.7 0.0 24.0 46. 844. 100. 10. 9 18.5 0.0 24.4 40. 866. 100. 10. 8 20.0 0.0 22.3 31. 889. 100. 9. 7 21.0 0.0 18.0 16. 913. 100. 6. 6 21.7 0.0 13.7 348. 938. 100. 3. 5 22.7 0.7 13.2 317. 959. 96. 2. 4 23.8 1.6 14.9 299. 975. 91. 1. 3 24.7 2.5 16.7 289. 989. 86. 1. 2 24.9 2.9 17.3 279. 999. 84. 1. 1 24.8 2.0 12.0 281. 1005. 88. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2508261800 787935 **************************************************** PBO 2508261800 FORECAST PROJECTION=12 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.0 7.6 17.8 317. 104. 29. 1. 43 -75.4 7.7 17.5 291. 112. 29. 3. 42 -72.6 9.2 18.0 287. 120. 24. 6. 41 -71.3 5.4 7.4 249. 129. 44. 8. 40 -71.5 4.8 25.2 168. 139. 49. 9. 39 -69.8 4.7 28.7 165. 149. 50. 5. 38 -66.0 4.7 24.2 166. 161. 52. 0. 37 -61.9 4.6 20.7 162. 173. 54. -3. 36 -57.8 4.5 17.2 155. 186. 56. -5. 35 -53.6 4.4 14.2 147. 199. 58. -5. 34 -49.5 4.3 12.0 136. 213. 61. -5. 33 -45.5 4.1 10.8 123. 229. 63. -3. 32 -41.8 3.9 10.4 109. 244. 66. -1. 31 -38.2 3.7 10.7 96. 261. 68. 0. 30 -34.7 3.5 11.5 84. 278. 71. 1. 29 -31.2 3.2 12.5 75. 297. 73. 1. 28 -27.8 3.0 14.1 69. 316. 76. 0. 27 -24.5 2.7 15.4 67. 337. 78. -1. 26 -21.3 2.7 15.9 67. 358. 79. -0. 25 -18.0 2.9 16.3 67. 380. 78. -0. 24 -14.8 2.8 17.4 69. 404. 79. -1. 23 -12.0 2.4 19.4 72. 429. 82. -1. 22 -9.3 2.8 22.2 77. 454. 80. -2. 21 -6.6 2.4 25.2 81. 482. 83. -2. 20 -3.8 2.6 27.4 86. 510. 82. -3. 19 -1.3 2.4 28.5 89. 540. 84. -7. 18 1.5 3.0 28.1 91. 571. 80. -11. 17 2.4 0.9 26.1 91. 603. 94. -14. 16 5.5 0.4 23.6 88. 638. 97. -18. 15 8.0 0.0 22.4 81. 673. 100. -22. 14 10.6 0.0 22.1 75. 711. 100. -29. 13 13.0 0.1 21.4 68. 750. 100. -37. 12 15.2 0.1 19.1 56. 791. 99. -44. 11 16.8 0.1 15.4 38. 823. 99. -47. 10 17.8 0.1 13.1 23. 845. 99. -45. 9 18.7 0.1 11.5 0. 868. 99. -41. 8 19.4 0.1 10.5 334. 890. 99. -34. 7 20.3 0.1 10.5 305. 914. 99. -24. 6 21.2 0.1 11.3 282. 939. 99. -14. 5 22.0 0.1 10.2 278. 960. 100. -7. 4 22.6 0.1 8.1 283. 977. 100. -3. 3 23.3 0.2 5.9 290. 990. 99. -1. 2 23.9 0.4 4.2 287. 1001. 98. -0. 1 24.5 0.6 3.0 279. 1006. 97. -0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1009. **************************************************** STATION = 9.35N 82.25W PBO 2508270000 787935 **************************************************** PBO 2508270000 FORECAST PROJECTION=18 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.8 5.1 6.9 122. 104. 44. -1. 43 -77.8 6.0 4.9 164. 112. 38. -1. 42 -75.2 7.3 7.0 211. 120. 31. -2. 41 -71.5 8.7 5.5 198. 129. 26. -1. 40 -68.3 11.5 11.7 103. 139. 18. -0. 39 -66.2 11.6 24.1 94. 149. 18. 0. 38 -63.9 8.4 25.4 87. 161. 31. 0. 37 -61.0 5.0 22.4 79. 173. 52. -1. 36 -57.6 4.5 20.2 77. 186. 56. -2. 35 -54.0 4.6 18.5 78. 199. 57. -2. 34 -50.6 4.3 15.9 81. 213. 60. -3. 33 -47.0 4.1 13.0 83. 228. 62. -3. 32 -43.1 4.0 11.2 82. 244. 65. -2. 31 -39.2 3.7 11.7 73. 261. 68. -2. 30 -35.4 3.5 14.5 64. 278. 70. -1. 29 -31.8 4.0 17.6 64. 296. 68. -0. 28 -28.4 5.4 19.2 62. 316. 60. 0. 27 -25.0 7.7 17.8 67. 336. 49. -0. 26 -21.7 9.2 13.7 80. 357. 43. -1. 25 -18.7 6.9 9.6 98. 380. 55. -2. 24 -15.4 6.7 8.2 115. 403. 56. -3. 23 -12.3 5.4 10.4 113. 428. 64. -4. 22 -9.2 6.8 15.5 106. 453. 58. -8. 21 -6.8 4.0 19.9 103. 481. 73. -12. 20 -3.7 4.3 21.8 101. 509. 72. -17. 19 -1.8 2.1 21.7 98. 539. 86. -23. 18 0.2 0.9 18.8 90. 570. 93. -26. 17 3.2 0.1 14.6 77. 602. 100. -25. 16 6.5 0.1 13.6 58. 636. 99. -26. 15 9.9 0.1 15.6 45. 672. 99. -35. 14 12.4 0.2 16.2 37. 709. 99. -48. 13 14.4 0.2 15.5 28. 749. 99. -57. 12 16.4 0.1 14.9 17. 789. 99. -58. 11 17.8 0.1 14.7 4. 821. 99. -54. 10 18.7 0.1 14.1 357. 844. 99. -48. 9 19.6 0.1 14.1 346. 866. 99. -40. 8 20.4 0.1 14.3 335. 888. 100. -31. 7 21.3 0.1 15.3 322. 913. 100. -20. 6 22.0 0.0 16.9 306. 938. 100. -10. 5 22.8 0.2 18.4 294. 958. 99. -4. 4 23.4 0.4 19.9 283. 975. 98. -1. 3 23.9 0.7 19.9 273. 988. 96. 1. 2 24.1 0.9 15.9 265. 999. 95. 1. 1 24.5 1.1 12.0 260. 1005. 94. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2508270600 787935 **************************************************** PBO 2508270600 FORECAST PROJECTION=24 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.8 5.3 7.4 27. 104. 42. -0. 43 -77.6 6.2 6.8 350. 112. 36. 0. 42 -75.3 7.2 5.6 330. 120. 32. 0. 41 -72.3 8.9 4.7 62. 129. 25. 1. 40 -69.8 9.1 16.6 87. 139. 25. 1. 39 -67.4 7.5 18.3 98. 149. 34. 0. 38 -64.2 7.1 18.0 108. 161. 37. -1. 37 -60.6 8.6 16.0 109. 173. 31. -1. 36 -57.1 9.9 11.7 106. 186. 27. -1. 35 -53.6 9.7 8.4 99. 199. 29. -0. 34 -49.9 9.0 6.7 90. 213. 34. 1. 33 -46.1 9.0 6.8 82. 228. 35. 2. 32 -42.6 8.0 8.6 82. 244. 41. 3. 31 -38.9 8.2 11.4 94. 261. 41. 3. 30 -35.2 7.9 14.7 104. 278. 44. 3. 29 -31.3 8.3 15.7 101. 297. 44. 2. 28 -27.6 6.9 17.0 85. 316. 52. 1. 27 -24.0 7.7 18.6 76. 336. 49. -0. 26 -20.6 10.1 18.5 83. 358. 40. -2. 25 -18.5 3.0 17.7 101. 380. 77. -4. 24 -15.4 4.6 17.8 119. 403. 68. -7. 23 -12.9 4.3 19.0 121. 428. 70. -10. 22 -9.9 5.0 19.6 117. 454. 67. -13. 21 -7.1 3.4 18.7 119. 481. 77. -15. 20 -4.0 2.6 16.2 128. 509. 82. -14. 19 -1.7 1.1 14.5 139. 539. 92. -11. 18 0.4 -0.0 14.7 142. 570. 100. -6. 17 3.3 0.0 13.8 135. 603. 100. -0. 16 6.0 0.1 13.0 115. 637. 100. 4. 15 8.6 0.1 13.8 94. 673. 99. 7. 14 11.0 0.1 14.2 78. 710. 99. 8. 13 13.4 0.2 14.9 60. 749. 99. 8. 12 15.7 0.2 16.1 43. 790. 99. 2. 11 17.4 0.2 17.2 28. 822. 99. -6. 10 18.4 0.2 16.7 20. 844. 99. -14. 9 19.3 0.2 16.0 8. 867. 99. -19. 8 20.0 0.1 14.4 353. 889. 99. -19. 7 20.8 0.1 13.4 334. 914. 99. -13. 6 21.5 0.1 13.4 309. 939. 99. -5. 5 22.0 0.1 13.0 294. 959. 99. 2. 4 22.4 0.1 12.1 279. 976. 100. 6. 3 22.7 0.1 10.2 257. 989. 100. 5. 2 23.1 0.1 8.1 233. 1000. 99. 4. 1 23.5 0.4 7.2 218. 1006. 98. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2508271200 787935 **************************************************** PBO 2508271200 FORECAST PROJECTION=30 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.3 8.8 14.8 39. 104. 23. -1. 43 -75.8 8.2 7.7 35. 112. 27. -1. 42 -74.3 8.3 6.8 16. 120. 27. -2. 41 -72.0 9.5 9.5 25. 129. 23. -1. 40 -69.4 10.0 13.0 49. 139. 22. 0. 39 -67.4 7.9 17.2 77. 150. 32. 2. 38 -65.5 5.0 18.1 104. 161. 50. 3. 37 -63.1 4.6 16.9 124. 173. 53. 2. 36 -59.2 4.6 19.4 115. 186. 55. -1. 35 -55.1 4.4 20.1 118. 199. 58. -5. 34 -50.9 4.3 20.0 121. 214. 60. -9. 33 -46.7 4.1 20.1 122. 229. 63. -14. 32 -42.7 3.9 20.6 121. 244. 65. -18. 31 -38.8 3.7 21.1 119. 261. 68. -21. 30 -34.9 3.5 21.6 116. 279. 71. -23. 29 -31.2 3.2 21.9 114. 297. 73. -23. 28 -27.7 3.0 22.0 113. 316. 76. -23. 27 -24.3 2.6 22.0 111. 337. 79. -20. 26 -21.3 2.0 21.8 108. 358. 84. -16. 25 -18.5 1.5 21.8 103. 381. 88. -11. 24 -15.7 1.7 22.2 98. 404. 86. -5. 23 -13.0 2.3 23.0 94. 429. 83. 2. 22 -10.3 3.1 23.9 92. 455. 78. 8. 21 -7.5 4.2 24.1 92. 482. 72. 13. 20 -4.7 4.8 23.3 92. 510. 69. 17. 19 -1.6 5.2 21.9 95. 540. 68. 20. 18 1.4 4.7 21.1 97. 571. 71. 23. 17 3.9 3.4 21.0 95. 604. 79. 25. 16 6.0 2.1 20.3 89. 638. 86. 24. 15 8.0 1.1 18.0 79. 674. 93. 21. 14 10.3 0.8 14.5 64. 711. 95. 17. 13 12.6 1.4 12.5 42. 750. 91. 12. 12 14.8 3.3 12.4 25. 791. 81. 10. 11 16.5 4.4 12.3 16. 823. 75. 9. 10 17.2 3.4 12.1 5. 845. 81. 9. 9 18.0 2.1 11.9 351. 867. 88. 8. 8 19.1 1.6 11.7 339. 890. 90. 7. 7 20.5 1.4 12.0 331. 914. 92. 6. 6 22.2 1.8 13.2 320. 939. 89. 4. 5 23.7 2.8 14.7 307. 960. 84. 1. 4 25.1 4.0 15.4 299. 976. 79. -0. 3 26.3 5.4 15.4 296. 990. 72. -1. 2 27.1 6.9 15.1 290. 1000. 66. -1. 1 25.6 3.4 10.4 276. 1006. 81. -0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2508271800 787935 **************************************************** PBO 2508271800 FORECAST PROJECTION=36 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.2 7.5 21.3 34. 104. 29. -0. 43 -78.2 5.4 11.9 12. 112. 41. -1. 42 -75.6 6.9 7.9 358. 120. 33. -1. 41 -72.5 8.5 6.7 30. 129. 27. -1. 40 -69.8 8.8 10.1 72. 139. 27. -0. 39 -67.1 8.7 14.6 88. 150. 28. 0. 38 -64.3 7.8 18.9 94. 161. 33. 1. 37 -61.2 7.9 22.1 97. 173. 34. 1. 36 -57.8 7.8 23.9 98. 186. 36. 2. 35 -54.1 7.0 23.0 100. 199. 42. 1. 34 -50.3 6.8 18.8 105. 214. 45. 1. 33 -46.5 6.5 17.2 115. 229. 48. 1. 32 -42.6 8.6 18.9 123. 244. 38. 1. 31 -38.7 10.4 18.1 124. 261. 32. 1. 30 -34.9 8.5 14.7 119. 279. 42. 0. 29 -31.4 5.1 10.2 114. 297. 61. 0. 28 -28.3 3.6 6.9 125. 316. 71. 0. 27 -25.0 3.0 7.2 136. 337. 76. 0. 26 -22.1 2.6 8.7 137. 358. 79. 1. 25 -19.3 2.4 10.2 122. 380. 81. 1. 24 -16.3 2.8 13.1 107. 404. 79. 2. 23 -13.1 3.6 15.4 104. 429. 75. 3. 22 -10.0 4.5 16.1 105. 454. 69. 4. 21 -6.9 5.1 17.0 108. 482. 67. 4. 20 -3.8 6.1 17.6 108. 510. 63. 3. 19 -0.8 7.6 16.5 106. 540. 56. 2. 18 2.1 8.3 14.9 101. 571. 54. 1. 17 4.5 6.9 14.5 96. 603. 61. -1. 16 6.5 4.2 14.4 94. 637. 75. -3. 15 8.3 1.4 13.9 91. 673. 91. -5. 14 10.5 1.0 12.6 84. 711. 93. -5. 13 12.6 0.8 11.1 79. 750. 95. -5. 12 15.1 1.7 9.6 73. 790. 90. -2. 11 16.3 1.3 8.0 61. 823. 92. 0. 10 17.2 1.0 7.4 47. 845. 94. 1. 9 18.2 1.1 7.2 33. 867. 93. 3. 8 19.4 1.4 7.1 25. 889. 91. 3. 7 20.8 1.4 7.1 25. 914. 92. 4. 6 22.5 1.6 5.9 14. 939. 91. 3. 5 24.1 2.4 4.8 358. 959. 86. 2. 4 25.5 3.5 4.2 344. 976. 81. 1. 3 26.5 4.2 3.6 338. 989. 78. 0. 2 27.3 4.5 3.8 342. 1000. 76. -0. 1 27.7 4.1 2.7 353. 1006. 78. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2508280000 787935 **************************************************** PBO 2508280000 FORECAST PROJECTION=42 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.2 7.5 30.4 86. 104. 29. -0. 43 -76.9 8.1 28.5 93. 112. 27. -1. 42 -75.0 8.4 27.1 90. 120. 26. -1. 41 -72.3 9.5 28.0 85. 129. 23. -0. 40 -69.1 11.3 27.2 79. 139. 18. 0. 39 -66.1 11.8 25.3 75. 150. 18. 1. 38 -63.5 9.7 19.9 77. 161. 26. 1. 37 -60.7 8.3 11.9 91. 173. 33. 1. 36 -57.8 5.9 7.2 142. 186. 47. 1. 35 -54.5 4.8 6.3 159. 199. 56. 1. 34 -50.7 4.4 7.4 144. 214. 59. 0. 33 -46.9 4.3 8.8 138. 229. 62. 0. 32 -43.1 4.8 8.9 125. 244. 59. 1. 31 -39.2 7.1 10.3 118. 261. 47. 1. 30 -35.3 9.3 11.3 115. 279. 38. 1. 29 -31.4 9.7 9.9 112. 297. 38. 1. 28 -27.8 9.7 8.3 117. 316. 39. 1. 27 -24.4 10.0 7.7 126. 337. 39. 1. 26 -21.5 10.2 8.5 125. 358. 39. 1. 25 -18.8 9.1 10.9 111. 380. 44. 1. 24 -15.8 8.1 14.4 99. 404. 50. 2. 23 -12.6 8.6 14.9 98. 428. 48. 2. 22 -9.3 8.4 13.5 102. 454. 50. 3. 21 -6.2 7.3 13.9 104. 481. 56. 3. 20 -3.4 5.9 18.5 101. 510. 63. 4. 19 -0.9 4.7 21.7 99. 540. 70. 4. 18 1.8 4.9 21.5 98. 571. 70. 5. 17 4.5 5.7 19.4 96. 603. 66. 5. 16 7.1 6.4 16.2 93. 637. 64. 4. 15 9.5 5.8 12.6 89. 673. 67. 4. 14 11.3 3.3 9.8 75. 710. 80. 3. 13 12.5 1.0 8.3 57. 749. 93. 2. 12 14.7 2.2 6.6 49. 790. 87. -0. 11 16.0 1.9 4.8 31. 822. 89. -3. 10 17.4 2.3 4.7 13. 844. 87. -3. 9 18.7 2.4 4.5 8. 867. 86. -3. 8 19.8 1.6 4.8 13. 889. 91. -2. 7 21.0 0.6 5.6 8. 914. 97. -2. 6 22.7 1.0 6.2 352. 938. 94. -1. 5 24.4 2.3 6.2 335. 959. 87. -0. 4 25.7 3.7 7.4 317. 976. 80. 0. 3 26.5 4.2 10.0 315. 989. 78. 0. 2 26.6 2.5 10.7 318. 1000. 86. 0. 1 26.9 2.3 8.5 317. 1005. 87. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2508280600 787935 **************************************************** PBO 2508280600 FORECAST PROJECTION=48 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.6 6.2 28.6 91. 104. 36. -0. 43 -77.7 5.8 23.5 96. 112. 39. -0. 42 -75.4 6.0 25.8 102. 120. 39. -1. 41 -72.7 6.9 26.8 101. 129. 35. -1. 40 -69.8 7.5 27.0 96. 139. 33. -0. 39 -66.7 8.1 27.7 89. 150. 31. 0. 38 -63.5 9.0 28.1 83. 161. 28. 1. 37 -60.1 10.4 26.7 79. 173. 24. 1. 36 -56.9 10.5 21.5 73. 186. 25. 2. 35 -53.4 9.3 13.0 68. 199. 31. 2. 34 -50.1 9.1 8.1 64. 214. 33. 2. 33 -46.8 9.6 6.8 88. 229. 32. 2. 32 -43.5 10.1 10.4 125. 244. 32. 2. 31 -39.9 9.4 14.7 136. 261. 36. 2. 30 -35.9 7.6 15.7 136. 279. 46. 2. 29 -32.0 6.1 13.5 135. 297. 55. 1. 28 -28.2 6.9 10.3 132. 316. 51. 1. 27 -24.5 8.5 9.0 129. 337. 45. 1. 26 -21.1 9.4 8.8 128. 358. 43. 1. 25 -18.1 10.0 8.7 120. 380. 41. 2. 24 -15.3 10.1 10.1 105. 404. 42. 2. 23 -12.5 8.4 13.0 100. 429. 49. 1. 22 -9.5 6.3 16.0 102. 454. 60. 1. 21 -6.6 4.5 17.9 108. 482. 70. 0. 20 -3.7 3.5 18.6 111. 510. 77. -0. 19 -1.3 2.6 18.0 110. 540. 83. -0. 18 0.9 1.7 17.3 107. 571. 88. 1. 17 3.4 2.0 15.8 103. 603. 87. 2. 16 6.2 2.7 14.3 97. 638. 83. 2. 15 8.7 2.2 12.6 89. 673. 86. 2. 14 10.8 1.8 10.4 75. 711. 89. 1. 13 12.8 1.2 8.3 62. 750. 92. -1. 12 15.3 2.7 6.3 49. 791. 84. -2. 11 16.6 3.2 4.8 36. 823. 81. -2. 10 17.5 3.0 4.2 31. 845. 83. -1. 9 18.3 2.0 3.6 24. 867. 88. -0. 8 19.3 1.0 3.5 11. 889. 94. 1. 7 20.8 0.5 4.2 5. 914. 97. 1. 6 22.5 0.8 5.4 358. 939. 95. 1. 5 24.0 1.5 6.5 334. 960. 91. 1. 4 25.3 2.8 8.2 310. 976. 85. 0. 3 26.1 4.3 10.2 296. 990. 77. 0. 2 26.5 5.4 9.5 279. 1000. 72. 0. 1 26.2 3.7 6.3 254. 1006. 80. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2508281200 787935 **************************************************** PBO 2508281200 FORECAST PROJECTION=54 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -78.5 5.4 24.7 71. 104. 41. -0. 43 -79.5 4.7 12.9 84. 112. 46. -1. 42 -76.5 4.7 10.0 94. 120. 48. -1. 41 -73.4 4.7 11.5 87. 129. 49. -0. 40 -70.3 6.4 16.7 75. 139. 39. 1. 39 -67.5 7.1 22.3 71. 149. 36. 4. 38 -64.5 6.3 25.3 81. 161. 42. 5. 37 -61.7 5.6 27.1 96. 173. 47. 4. 36 -58.3 4.9 27.1 104. 186. 53. 2. 35 -54.4 4.8 24.3 106. 199. 55. -2. 34 -50.4 4.3 20.7 105. 213. 60. -7. 33 -46.5 4.1 17.5 106. 228. 63. -13. 32 -42.8 3.9 15.9 108. 244. 65. -21. 31 -39.0 3.7 16.0 109. 261. 68. -30. 30 -34.9 3.5 15.9 112. 278. 71. -42. 29 -30.8 3.2 15.0 113. 297. 73. -50. 28 -27.0 2.9 13.3 112. 316. 76. -54. 27 -24.1 0.5 11.6 110. 336. 96. -53. 26 -20.6 0.1 10.5 106. 358. 99. -49. 25 -17.0 0.6 10.0 99. 380. 95. -43. 24 -14.2 0.0 9.8 88. 404. 100. -35. 23 -11.5 0.0 9.6 76. 428. 100. -27. 22 -9.0 0.0 9.5 65. 454. 100. -19. 21 -6.6 0.0 9.4 55. 481. 100. -12. 20 -4.2 0.0 9.0 49. 510. 100. -4. 19 -1.9 0.2 8.0 47. 540. 99. 3. 18 0.7 1.0 6.5 48. 571. 93. 10. 17 2.2 0.6 5.1 56. 603. 96. 17. 16 5.5 1.5 5.2 67. 637. 90. 21. 15 8.3 1.7 6.7 64. 673. 89. 23. 14 10.6 1.4 9.4 52. 710. 91. 24. 13 13.0 0.9 12.0 44. 750. 94. 21. 12 15.1 0.6 11.3 35. 790. 96. 15. 11 16.8 0.7 9.5 25. 822. 96. 10. 10 17.7 0.3 7.8 15. 845. 98. 8. 9 18.6 0.1 6.3 5. 867. 99. 7. 8 19.6 0.1 5.0 349. 889. 99. 8. 7 20.6 0.2 4.7 322. 914. 98. 8. 6 21.8 0.6 5.8 309. 939. 96. 9. 5 22.8 1.1 7.1 307. 959. 94. 8. 4 23.7 1.7 8.3 304. 976. 90. 6. 3 24.3 2.4 8.6 303. 989. 86. 4. 2 24.6 2.4 5.5 304. 1000. 86. 2. 1 25.0 2.3 3.3 294. 1006. 87. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2508281800 787935 **************************************************** PBO 2508281800 FORECAST PROJECTION=60 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.8 5.8 38.9 60. 104. 39. 0. 43 -81.7 4.8 27.8 63. 112. 44. 0. 42 -80.7 4.6 19.2 71. 120. 46. -0. 41 -77.9 4.7 10.8 72. 129. 47. -1. 40 -74.3 4.7 8.8 81. 139. 48. -2. 39 -70.4 4.7 8.5 86. 149. 50. -3. 38 -66.2 4.7 7.8 91. 161. 52. -4. 37 -62.0 4.6 6.3 103. 173. 54. -5. 36 -57.8 4.5 4.9 127. 186. 56. -5. 35 -53.7 4.4 4.5 164. 199. 58. -5. 34 -49.7 4.3 5.8 195. 213. 61. -4. 33 -45.9 4.1 8.0 208. 228. 63. -3. 32 -41.8 6.3 9.5 211. 244. 50. -2. 31 -37.8 6.6 9.6 210. 261. 50. -1. 30 -33.8 6.2 8.6 206. 278. 54. -2. 29 -30.1 5.4 6.7 198. 297. 59. -3. 28 -26.5 4.3 5.0 186. 316. 67. -4. 27 -23.2 3.8 4.4 173. 336. 71. -4. 26 -20.2 3.0 4.5 163. 358. 77. -4. 25 -17.5 2.2 5.0 144. 380. 83. -2. 24 -14.9 1.8 6.7 118. 404. 86. -1. 23 -12.0 2.1 10.6 103. 428. 84. 1. 22 -9.3 2.9 15.1 97. 454. 79. 2. 21 -6.9 3.0 18.8 95. 481. 79. 2. 20 -4.5 3.2 21.3 94. 510. 79. 2. 19 -2.0 3.7 22.2 92. 540. 76. 3. 18 0.6 4.0 21.8 94. 571. 75. 4. 17 3.3 4.1 20.6 98. 603. 74. 4. 16 5.9 3.8 18.3 100. 637. 77. 4. 15 8.4 3.1 15.1 98. 673. 81. 3. 14 10.8 2.5 12.8 90. 710. 85. 2. 13 12.9 1.6 11.6 82. 749. 90. 2. 12 15.0 1.2 11.0 83. 790. 92. 2. 11 16.7 1.3 11.0 85. 822. 92. 2. 10 17.6 1.2 11.5 87. 844. 93. 3. 9 18.9 1.6 12.1 85. 867. 90. 3. 8 20.4 2.3 12.5 83. 889. 87. 4. 7 21.7 2.6 10.9 85. 913. 85. 5. 6 23.0 2.8 4.8 88. 938. 84. 5. 5 24.1 3.2 1.6 266. 959. 82. 5. 4 24.9 3.5 5.9 267. 976. 81. 4. 3 25.6 3.9 8.5 266. 989. 79. 3. 2 26.0 3.5 8.4 265. 999. 81. 2. 1 26.5 3.3 7.5 266. 1005. 82. 1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2508290000 787935 **************************************************** PBO 2508290000 FORECAST PROJECTION=66 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -75.2 8.9 25.6 140. 104. 24. 0. 43 -73.5 9.6 27.6 113. 112. 22. 1. 42 -72.7 9.7 29.5 87. 120. 22. 2. 41 -72.8 9.8 25.3 61. 129. 22. 2. 40 -72.4 7.9 20.8 42. 139. 30. 2. 39 -69.8 6.1 17.3 40. 149. 41. 1. 38 -66.0 6.0 9.9 44. 161. 43. 0. 37 -61.9 6.1 3.8 36. 173. 44. 0. 36 -57.8 6.9 6.2 346. 186. 41. -0. 35 -53.8 7.3 9.8 328. 199. 40. -1. 34 -49.7 7.1 11.1 306. 213. 43. -1. 33 -45.8 5.9 11.9 287. 228. 51. -1. 32 -41.9 4.8 9.3 283. 244. 60. -1. 31 -38.1 4.2 6.7 281. 261. 64. -1. 30 -34.3 3.7 5.7 299. 278. 69. -2. 29 -30.8 3.3 6.5 335. 297. 73. -2. 28 -27.2 3.1 6.7 4. 316. 75. -2. 27 -23.8 6.5 9.6 45. 336. 55. -2. 26 -20.5 12.0 13.6 53. 358. 33. -2. 25 -17.7 10.6 14.5 58. 380. 39. -2. 24 -15.2 6.3 14.6 70. 403. 59. -1. 23 -12.8 2.9 18.3 80. 428. 79. -0. 22 -10.2 3.2 22.8 83. 454. 77. 1. 21 -7.5 3.9 24.3 84. 481. 74. 2. 20 -4.5 4.0 23.8 86. 509. 74. 3. 19 -1.6 4.2 21.7 90. 539. 73. 4. 18 0.8 3.2 19.0 98. 570. 79. 4. 17 2.9 2.3 16.8 106. 603. 85. 3. 16 5.6 2.7 14.8 111. 637. 83. 3. 15 8.4 2.8 13.5 109. 672. 82. 2. 14 10.9 2.7 11.4 105. 710. 83. 1. 13 13.4 2.6 8.2 103. 749. 84. 0. 12 15.7 2.6 3.8 108. 790. 85. 0. 11 17.6 3.2 1.6 183. 822. 82. 0. 10 18.7 3.5 3.9 229. 844. 80. 0. 9 19.9 3.8 4.8 229. 866. 79. 1. 8 21.0 3.8 4.2 223. 888. 79. 1. 7 22.3 4.0 3.3 205. 913. 78. 1. 6 23.6 3.9 2.7 178. 937. 79. 0. 5 24.9 4.2 1.6 168. 958. 78. -0. 4 26.1 4.7 0.4 15. 975. 76. -0. 3 26.8 4.8 3.1 1. 988. 75. -0. 2 27.0 3.8 6.1 359. 999. 80. -1. 1 27.1 2.4 5.2 2. 1004. 87. -1. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2508290600 787935 **************************************************** PBO 2508290600 FORECAST PROJECTION=72 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -75.2 9.7 15.7 170. 104. 21. 0. 43 -74.1 9.9 22.9 136. 112. 21. 1. 42 -71.6 11.6 21.5 129. 120. 16. 1. 41 -68.7 13.5 19.5 90. 129. 13. 2. 40 -67.7 14.3 25.9 45. 139. 11. 2. 39 -67.5 11.6 29.7 29. 150. 18. 2. 38 -65.7 7.8 27.3 22. 161. 33. 2. 37 -62.0 7.5 24.5 15. 173. 36. 2. 36 -58.0 9.3 20.1 6. 186. 30. 1. 35 -54.1 7.9 16.8 353. 199. 37. 1. 34 -50.7 4.3 14.4 347. 214. 60. 1. 33 -47.6 4.2 11.4 347. 229. 62. 0. 32 -44.0 4.0 8.5 356. 244. 64. -1. 31 -39.6 3.8 7.7 3. 261. 67. -2. 30 -35.2 3.5 7.7 13. 279. 70. -3. 29 -31.2 3.2 10.0 30. 297. 73. -2. 28 -28.3 3.0 11.3 36. 316. 75. -1. 27 -25.3 5.6 13.5 52. 337. 60. -0. 26 -21.6 11.5 15.9 65. 358. 35. 0. 25 -18.4 8.3 16.5 74. 380. 48. 1. 24 -15.1 4.7 17.6 76. 404. 67. 1. 23 -12.1 3.7 18.2 76. 429. 74. 1. 22 -9.2 3.6 17.6 79. 454. 75. 1. 21 -6.6 3.7 15.1 81. 482. 75. 1. 20 -4.2 4.0 12.5 80. 510. 73. 0. 19 -2.0 3.1 11.7 85. 540. 79. -0. 18 0.6 2.7 12.1 104. 571. 82. 0. 17 3.0 2.5 13.2 113. 603. 83. 1. 16 5.6 3.3 13.1 116. 638. 79. 2. 15 8.1 3.4 11.5 123. 673. 79. 3. 14 10.7 3.2 9.3 128. 711. 80. 4. 13 12.9 2.3 3.2 109. 750. 86. 4. 12 15.3 2.5 5.5 313. 790. 85. 5. 11 16.7 2.0 9.4 302. 822. 88. 5. 10 17.5 1.5 9.0 308. 845. 91. 5. 9 18.5 1.4 7.6 320. 867. 92. 5. 8 19.5 1.1 6.3 335. 889. 93. 5. 7 20.7 0.9 4.6 348. 914. 95. 3. 6 22.0 1.0 3.4 6. 939. 94. 1. 5 23.3 1.1 4.7 359. 959. 93. -1. 4 24.5 1.6 5.8 348. 976. 91. -1. 3 25.4 1.7 6.1 337. 989. 90. -1. 2 26.2 2.1 5.4 323. 1000. 88. -1. 1 26.5 2.1 4.3 299. 1006. 88. -0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2508291200 787935 **************************************************** PBO 2508291200 FORECAST PROJECTION=78 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -74.5 10.4 4.4 262. 104. 19. -0. 43 -73.2 11.0 6.2 166. 112. 17. -0. 42 -73.3 9.4 13.2 157. 120. 23. -1. 41 -71.7 9.4 9.6 107. 129. 23. -1. 40 -68.8 10.4 15.6 64. 139. 21. -0. 39 -67.6 8.0 24.8 47. 150. 31. 1. 38 -65.6 5.7 27.9 38. 161. 45. 2. 37 -62.2 7.1 27.0 30. 173. 38. 4. 36 -58.5 8.8 25.8 18. 186. 31. 5. 35 -54.6 8.6 24.8 12. 199. 34. 6. 34 -50.8 10.3 22.4 1. 213. 28. 7. 33 -47.1 12.3 21.1 345. 228. 23. 8. 32 -43.6 11.4 21.6 336. 244. 27. 7. 31 -39.8 8.4 21.0 332. 261. 40. 6. 30 -35.7 7.5 18.4 331. 278. 46. 5. 29 -31.4 7.6 13.5 337. 297. 47. 4. 28 -27.9 5.1 7.4 18. 316. 61. 3. 27 -24.6 6.3 9.3 86. 337. 56. 2. 26 -21.4 9.6 14.0 99. 358. 42. 2. 25 -18.5 8.1 16.3 92. 380. 49. 2. 24 -15.1 6.1 16.2 98. 404. 60. 2. 23 -12.0 5.5 11.2 103. 428. 64. 2. 22 -9.3 3.9 7.7 105. 454. 74. 2. 21 -6.6 3.6 8.0 134. 481. 75. 2. 20 -4.0 3.9 11.2 143. 510. 74. 2. 19 -1.4 4.0 13.7 137. 540. 74. 1. 18 1.0 3.4 13.3 130. 571. 78. 0. 17 3.4 3.5 11.5 122. 603. 78. -3. 16 5.5 1.9 10.7 106. 637. 87. -7. 15 8.2 3.5 10.7 95. 673. 79. -10. 14 10.1 1.8 8.1 86. 710. 88. -11. 13 12.9 3.1 4.5 50. 749. 81. -9. 12 14.5 1.9 6.3 19. 790. 88. -9. 11 15.7 0.2 8.0 21. 822. 99. -12. 10 17.1 0.0 6.9 15. 844. 100. -15. 9 18.2 0.0 5.3 360. 867. 100. -16. 8 19.3 0.0 4.3 335. 889. 100. -15. 7 20.4 0.0 4.4 307. 914. 100. -13. 6 21.6 0.0 4.0 295. 938. 100. -9. 5 22.7 0.2 3.1 313. 959. 99. -6. 4 23.9 0.7 3.5 315. 976. 96. -4. 3 24.9 1.7 4.4 294. 989. 91. -2. 2 25.4 2.3 4.9 272. 1000. 87. -1. 1 25.5 1.7 3.2 241. 1006. 90. -0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2508291800 787935 **************************************************** PBO 2508291800 FORECAST PROJECTION=84 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.2 7.0 14.1 63. 104. 32. -0. 43 -79.2 4.6 9.2 141. 112. 47. -0. 42 -76.5 4.7 8.6 144. 120. 48. -1. 41 -73.6 6.3 11.0 90. 129. 38. -1. 40 -71.2 6.2 14.1 40. 139. 39. -1. 39 -69.0 5.9 22.1 7. 150. 42. -1. 38 -65.9 6.4 21.8 360. 161. 40. -1. 37 -62.4 6.7 20.8 360. 173. 40. -2. 36 -58.5 6.9 19.7 359. 186. 40. -2. 35 -54.5 7.2 19.1 357. 199. 41. -3. 34 -50.5 7.7 17.8 355. 214. 40. -3. 33 -46.4 9.3 16.0 348. 229. 34. -3. 32 -42.3 12.1 16.0 330. 244. 26. -2. 31 -38.2 15.6 17.9 309. 261. 18. -1. 30 -34.4 16.2 18.9 297. 279. 18. -0. 29 -30.6 14.8 17.2 293. 297. 22. 1. 28 -27.0 10.6 12.8 293. 316. 36. 1. 27 -23.7 9.1 7.8 303. 337. 43. 2. 26 -20.3 12.8 4.3 330. 358. 31. 2. 25 -17.1 15.4 4.3 52. 380. 25. 1. 24 -14.4 9.3 4.5 84. 404. 45. 1. 23 -12.7 3.0 1.9 94. 429. 78. 0. 22 -10.3 1.5 4.7 102. 454. 89. 0. 21 -7.5 1.9 10.8 103. 482. 86. 1. 20 -4.7 2.6 17.0 109. 510. 82. 1. 19 -1.9 3.5 21.1 113. 540. 77. 1. 18 0.8 3.9 23.0 115. 571. 75. 1. 17 3.3 4.2 21.5 113. 603. 74. 0. 16 6.0 4.5 17.8 106. 638. 73. -0. 15 8.3 3.7 13.8 105. 673. 78. -1. 14 10.1 2.7 13.5 105. 711. 83. -1. 13 11.9 1.4 13.4 107. 750. 91. -2. 12 14.5 2.5 9.4 113. 790. 85. -2. 11 15.8 1.2 3.3 99. 822. 93. -2. 10 17.1 0.7 3.3 78. 845. 95. -2. 9 18.5 0.8 2.7 68. 867. 95. -1. 8 19.9 1.0 1.9 42. 889. 94. -1. 7 21.4 1.3 1.7 353. 914. 92. 0. 6 23.0 2.1 2.5 337. 939. 88. 1. 5 24.4 3.2 3.6 330. 959. 83. 2. 4 25.4 3.6 4.4 327. 976. 80. 2. 3 26.1 3.8 5.5 326. 989. 80. 1. 2 26.5 3.0 6.2 329. 1000. 84. 1. 1 27.0 2.7 5.6 331. 1006. 85. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2508300000 787935 **************************************************** PBO 2508300000 FORECAST PROJECTION=90 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -75.7 8.7 4.3 49. 104. 24. -0. 43 -74.5 9.5 10.9 159. 112. 22. -1. 42 -72.2 10.4 8.0 121. 120. 20. -1. 41 -72.9 7.4 12.3 37. 129. 32. 0. 40 -71.6 6.1 20.6 8. 139. 40. 0. 39 -69.1 6.0 23.4 354. 149. 42. 0. 38 -65.9 6.6 24.1 336. 161. 39. 0. 37 -62.2 7.4 24.0 321. 173. 37. -0. 36 -58.3 6.8 22.4 308. 186. 41. -1. 35 -54.1 6.6 22.3 301. 199. 44. -1. 34 -49.9 6.4 23.2 297. 213. 47. -2. 33 -45.8 6.2 24.5 298. 228. 50. -2. 32 -42.0 7.5 25.8 308. 244. 44. -3. 31 -38.1 10.0 27.0 315. 261. 34. -3. 30 -34.3 12.1 27.5 318. 278. 28. -3. 29 -30.8 10.8 26.1 318. 297. 34. -2. 28 -27.7 8.2 21.8 319. 316. 46. -1. 27 -24.6 8.3 15.2 328. 336. 46. -0. 26 -21.4 11.9 10.7 350. 358. 33. 0. 25 -18.5 9.1 5.7 9. 380. 45. 1. 24 -15.9 3.7 2.5 28. 404. 73. 0. 23 -13.2 2.1 5.2 63. 428. 84. 0. 22 -10.3 1.6 12.7 86. 454. 88. -0. 21 -7.5 2.1 20.5 94. 481. 85. -0. 20 -5.2 2.0 25.7 100. 510. 86. -1. 19 -2.0 3.5 28.9 109. 539. 77. -1. 18 1.0 5.1 28.9 110. 570. 69. -1. 17 3.8 6.1 26.1 105. 603. 64. -2. 16 6.1 4.7 20.9 101. 637. 72. -4. 15 7.9 2.0 14.5 97. 673. 87. -5. 14 10.5 2.7 10.5 93. 710. 84. -5. 13 12.4 2.0 8.4 109. 749. 88. -5. 12 14.9 3.0 5.5 130. 790. 82. -3. 11 16.6 3.2 2.7 138. 822. 81. -1. 10 17.5 2.5 1.4 94. 844. 85. -0. 9 18.5 1.6 2.2 58. 866. 90. 0. 8 19.6 0.9 2.3 42. 889. 95. 1. 7 20.9 0.7 1.5 2. 913. 96. 1. 6 22.4 1.3 1.5 303. 938. 92. 2. 5 23.6 2.0 1.7 300. 959. 88. 2. 4 24.7 2.5 2.4 325. 975. 86. 2. 3 25.6 2.5 3.8 329. 988. 86. 1. 2 26.3 2.6 3.4 324. 999. 86. 1. 1 26.7 2.3 2.4 317. 1005. 87. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2508300600 787935 **************************************************** PBO 2508300600 FORECAST PROJECTION=96 LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.0 8.2 8.7 64. 104. 26. -0. 43 -75.7 8.1 7.5 253. 112. 27. -1. 42 -74.5 8.1 13.7 234. 120. 28. -1. 41 -71.4 9.8 13.7 206. 129. 22. -0. 40 -67.8 13.2 1.2 281. 139. 14. 1. 39 -66.5 10.8 16.6 19. 149. 21. 2. 38 -65.1 8.2 26.1 16. 161. 31. 3. 37 -62.3 7.0 27.8 3. 173. 39. 4. 36 -58.5 6.6 28.0 345. 186. 43. 3. 35 -55.1 5.5 22.7 331. 199. 50. 3. 34 -51.3 4.5 18.9 312. 213. 59. 2. 33 -47.1 4.4 17.3 298. 228. 60. 1. 32 -42.8 4.6 17.3 303. 244. 60. -0. 31 -38.7 4.8 20.5 314. 261. 60. -1. 30 -34.9 6.5 24.9 324. 278. 51. -1. 29 -31.4 6.3 25.9 329. 297. 54. -2. 28 -28.1 5.6 24.2 333. 316. 59. -2. 27 -24.9 6.4 21.2 345. 336. 55. -2. 26 -21.9 8.7 17.6 3. 358. 45. -1. 25 -19.3 7.4 10.3 29. 380. 52. 0. 24 -16.3 5.3 5.9 64. 404. 64. 1. 23 -13.2 4.5 7.1 86. 428. 69. 2. 22 -10.2 4.1 13.5 90. 454. 72. 2. 21 -7.3 3.8 17.7 98. 481. 74. 1. 20 -4.7 3.2 19.5 108. 510. 79. 1. 19 -2.0 4.2 23.0 116. 539. 73. -0. 18 0.6 6.4 25.4 119. 570. 62. -1. 17 3.2 7.4 25.1 120. 603. 58. -1. 16 5.8 6.5 21.7 123. 637. 63. -1. 15 8.1 3.5 12.5 129. 673. 79. -0. 14 10.2 1.8 9.1 120. 710. 88. 1. 13 12.3 1.3 10.5 101. 749. 92. 0. 12 14.6 2.1 7.7 96. 790. 87. -0. 11 16.6 3.1 3.6 94. 822. 82. 0. 10 17.9 3.3 1.6 73. 844. 81. 1. 9 19.0 3.1 1.7 55. 866. 82. 1. 8 20.0 2.2 2.2 54. 889. 87. 1. 7 21.1 1.2 1.8 14. 913. 93. 1. 6 22.5 1.2 3.0 322. 938. 93. 1. 5 23.6 1.8 3.8 312. 959. 90. 1. 4 24.7 2.6 4.1 308. 975. 86. 0. 3 25.6 3.2 4.3 294. 988. 82. 0. 2 26.2 4.2 5.2 272. 999. 78. 0. 1 26.0 2.7 3.9 241. 1005. 85. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2508301200 787935 **************************************************** PBO 2508301200 FORECAST PROJECTION=** LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.1 7.6 7.2 88. 104. 29. 0. 43 -75.7 7.6 7.5 277. 112. 30. 1. 42 -73.7 9.1 12.0 277. 120. 24. 2. 41 -71.7 9.4 7.5 296. 129. 23. 2. 40 -69.0 10.7 6.2 356. 139. 20. 1. 39 -66.7 10.0 11.6 17. 150. 23. -0. 38 -64.4 9.1 18.2 19. 161. 28. -1. 37 -61.7 8.2 22.9 17. 173. 33. -2. 36 -58.4 9.0 23.3 12. 186. 31. -2. 35 -54.7 9.5 20.9 3. 199. 30. -2. 34 -50.8 10.7 18.9 344. 213. 27. -1. 33 -47.1 7.7 17.6 338. 228. 41. -1. 32 -43.4 5.9 14.6 349. 244. 52. -2. 31 -39.4 7.5 17.4 4. 261. 45. -2. 30 -35.6 8.3 19.6 5. 278. 43. -2. 29 -32.0 7.7 18.1 357. 297. 47. -2. 28 -28.5 6.4 16.6 347. 316. 54. -1. 27 -25.1 5.6 15.4 344. 337. 60. -0. 26 -21.7 7.5 12.6 350. 358. 51. 1. 25 -19.0 11.1 7.9 52. 380. 37. 2. 24 -16.3 7.9 8.2 85. 404. 51. 2. 23 -13.4 5.6 7.2 86. 428. 63. 3. 22 -10.5 5.1 10.6 86. 454. 66. 3. 21 -7.5 5.2 14.6 95. 481. 66. 3. 20 -4.5 6.2 16.3 109. 510. 62. 3. 19 -1.7 6.9 19.4 112. 539. 59. 3. 18 0.8 7.5 22.6 107. 570. 57. 2. 17 3.0 6.7 23.1 107. 603. 61. 2. 16 5.3 5.7 18.9 105. 637. 67. 1. 15 7.5 4.0 14.1 104. 673. 76. 1. 14 10.0 2.6 9.3 106. 710. 84. 1. 13 12.3 2.0 6.4 92. 749. 88. 1. 12 14.3 1.0 6.9 92. 790. 94. 1. 11 15.6 0.3 4.7 79. 822. 98. 1. 10 17.2 1.3 3.6 64. 844. 92. 1. 9 18.6 2.2 3.4 50. 866. 87. 1. 8 19.9 2.4 3.4 36. 889. 86. 1. 7 21.2 2.1 3.5 16. 913. 88. 1. 6 22.6 1.9 4.0 356. 938. 89. 1. 5 23.7 2.2 4.6 345. 959. 88. 1. 4 24.7 2.7 5.2 337. 975. 85. 1. 3 25.6 3.5 5.5 320. 989. 81. 1. 2 26.1 4.6 5.7 296. 999. 76. 0. 1 26.0 3.7 4.5 265. 1005. 80. -0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2508301800 787935 **************************************************** PBO 2508301800 FORECAST PROJECTION=** LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.4 7.5 3.7 296. 104. 30. -0. 43 -76.1 7.5 13.4 305. 112. 30. -0. 42 -75.3 6.9 10.7 289. 120. 33. -0. 41 -73.1 7.3 7.2 272. 129. 32. -0. 40 -70.3 7.7 1.2 360. 139. 32. -1. 39 -67.8 7.3 9.2 59. 150. 34. -1. 38 -65.0 7.2 17.0 52. 161. 36. -1. 37 -61.8 7.0 17.6 46. 173. 39. -1. 36 -58.4 7.1 15.0 28. 186. 40. -1. 35 -54.7 8.4 13.7 6. 199. 35. -1. 34 -50.9 9.9 10.6 350. 214. 30. -1. 33 -47.0 9.0 9.5 338. 229. 35. -1. 32 -43.3 7.1 8.1 337. 244. 45. -1. 31 -39.5 7.2 9.5 335. 261. 46. -0. 30 -35.6 9.1 11.2 348. 279. 39. 0. 29 -31.7 10.7 12.3 3. 297. 34. 1. 28 -28.0 10.7 9.3 14. 316. 35. 1. 27 -24.7 9.3 6.3 19. 337. 42. 1. 26 -21.7 11.2 5.0 35. 358. 36. 1. 25 -18.2 14.8 4.4 88. 380. 26. 1. 24 -14.9 14.4 6.3 125. 404. 28. 1. 23 -12.1 10.4 6.8 118. 428. 42. 1. 22 -9.5 8.5 8.6 103. 454. 50. 1. 21 -6.9 7.4 11.2 103. 481. 56. 1. 20 -4.2 7.6 14.4 100. 510. 55. 1. 19 -1.7 8.2 16.9 98. 540. 54. 1. 18 0.9 8.3 17.5 96. 571. 54. 1. 17 3.4 8.1 17.4 95. 603. 55. 2. 16 5.7 7.4 16.8 94. 637. 59. 2. 15 7.7 3.5 15.0 91. 673. 79. 2. 14 10.3 4.1 11.8 86. 710. 76. 2. 13 12.2 1.7 11.0 86. 749. 89. 1. 12 14.6 2.0 10.8 94. 790. 88. -0. 11 15.7 0.4 9.9 102. 822. 97. -1. 10 17.1 0.8 8.9 98. 844. 95. -1. 9 18.3 0.8 8.3 88. 867. 95. -0. 8 19.6 0.8 7.5 76. 889. 95. 1. 7 21.0 1.0 5.5 58. 913. 94. 2. 6 22.6 1.8 4.6 27. 938. 90. 2. 5 24.0 2.6 5.6 356. 959. 85. 2. 4 25.3 3.4 6.6 347. 976. 82. 1. 3 26.3 4.0 7.3 341. 989. 79. 1. 2 27.1 4.3 7.5 337. 999. 77. 0. 1 27.5 3.8 6.4 339. 1005. 80. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2508310000 787935 **************************************************** PBO 2508310000 FORECAST PROJECTION=** LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -73.8 9.7 20.7 145. 104. 21. 0. 43 -72.3 11.3 3.9 31. 112. 17. 0. 42 -72.3 10.9 12.3 358. 120. 18. 0. 41 -72.8 7.5 11.7 356. 129. 31. 0. 40 -71.6 4.8 7.6 8. 139. 49. -0. 39 -68.9 4.7 5.4 36. 149. 50. -1. 38 -65.5 4.8 5.6 46. 161. 51. -1. 37 -61.9 6.3 4.8 44. 173. 43. -2. 36 -58.1 7.9 3.4 35. 186. 36. -2. 35 -54.3 10.1 2.4 2. 199. 28. -1. 34 -50.3 12.8 2.7 309. 213. 21. -1. 33 -46.4 15.0 4.3 296. 228. 17. -1. 32 -42.6 14.5 6.5 314. 244. 19. -1. 31 -39.0 12.3 9.5 325. 261. 26. -1. 30 -35.4 10.9 11.8 328. 278. 32. -1. 29 -31.7 11.0 13.9 334. 297. 33. -2. 28 -28.1 11.8 13.6 345. 316. 32. -2. 27 -24.9 11.8 9.9 359. 336. 32. -2. 26 -21.9 12.6 6.1 8. 358. 31. -1. 25 -19.0 12.0 2.8 20. 380. 34. 0. 24 -16.1 10.2 3.2 76. 404. 41. 1. 23 -13.0 9.3 7.9 85. 428. 46. 2. 22 -9.9 9.3 12.3 88. 454. 47. 3. 21 -6.9 9.7 15.7 92. 481. 46. 2. 20 -4.3 10.0 19.4 94. 509. 45. 1. 19 -1.8 8.5 23.3 96. 539. 52. 1. 18 0.8 7.5 25.2 100. 570. 57. 1. 17 3.6 7.9 25.5 100. 603. 56. 2. 16 6.3 8.2 24.2 99. 637. 56. 3. 15 8.5 7.2 22.7 99. 672. 61. 3. 14 10.5 5.8 19.6 100. 710. 67. 4. 13 12.6 5.0 14.7 96. 748. 72. 4. 12 15.0 5.1 11.0 86. 789. 72. 3. 11 16.5 4.0 9.4 75. 821. 77. 3. 10 17.5 2.9 8.3 66. 843. 83. 3. 9 18.9 2.7 7.5 55. 866. 85. 3. 8 20.3 2.7 7.3 40. 888. 85. 3. 7 21.9 2.9 7.5 19. 912. 84. 3. 6 23.6 3.6 7.6 358. 937. 80. 3. 5 25.0 4.2 7.8 341. 958. 77. 3. 4 26.2 4.7 8.0 331. 974. 76. 3. 3 27.1 5.1 8.1 331. 988. 74. 2. 2 27.7 5.3 8.7 337. 998. 73. 1. 1 27.4 3.0 6.7 346. 1004. 84. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1006. **************************************************** STATION = 9.35N 82.25W PBO 2508310600 787935 **************************************************** PBO 2508310600 FORECAST PROJECTION=** LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.3 7.8 5.1 214. 104. 28. -0. 43 -75.1 8.9 12.7 172. 112. 24. -0. 42 -71.2 12.1 9.4 150. 120. 15. 0. 41 -69.0 14.2 5.6 344. 129. 11. 1. 40 -67.6 14.2 15.1 338. 139. 12. 2. 39 -65.9 12.7 18.3 346. 150. 16. 3. 38 -64.2 9.2 16.4 355. 161. 27. 3. 37 -61.8 6.1 12.8 358. 173. 44. 3. 36 -58.5 4.9 6.9 342. 186. 53. 2. 35 -54.5 5.7 3.1 138. 199. 49. 0. 34 -50.6 4.5 4.1 150. 213. 58. -1. 33 -46.4 6.6 3.2 294. 228. 47. -1. 32 -42.6 11.3 7.2 326. 244. 28. -2. 31 -39.2 12.3 10.4 348. 261. 26. -1. 30 -35.8 11.0 11.7 359. 278. 31. 0. 29 -32.3 10.0 10.9 9. 297. 36. 1. 28 -28.7 10.0 8.3 27. 316. 38. 2. 27 -25.2 10.1 5.4 70. 337. 38. 2. 26 -21.8 10.0 5.3 114. 358. 40. 1. 25 -18.6 10.0 4.5 122. 380. 41. -0. 24 -15.5 10.2 4.4 107. 404. 41. -1. 23 -12.3 9.3 7.7 100. 428. 46. -1. 22 -9.4 7.0 13.9 98. 454. 57. -1. 21 -6.8 5.6 18.2 98. 481. 64. -1. 20 -4.5 4.2 20.2 99. 510. 73. -1. 19 -2.0 3.1 20.5 101. 539. 80. -0. 18 0.3 1.8 20.0 103. 571. 88. -0. 17 2.7 1.4 18.6 101. 603. 91. -1. 16 5.1 1.0 16.2 94. 637. 93. -2. 15 7.4 0.8 14.7 84. 673. 94. -2. 14 9.4 0.2 13.6 75. 710. 99. -2. 13 11.7 0.7 11.5 67. 749. 95. -2. 12 14.5 2.8 9.3 62. 790. 83. -0. 11 16.2 3.7 7.3 58. 822. 79. 2. 10 17.1 3.4 5.9 54. 844. 81. 4. 9 17.8 2.2 5.4 50. 867. 87. 6. 8 18.8 1.2 5.2 40. 889. 93. 7. 7 20.3 0.9 4.7 14. 913. 95. 6. 6 22.3 1.6 4.9 346. 938. 91. 4. 5 23.9 2.5 5.2 322. 959. 86. 2. 4 25.2 3.6 5.7 299. 975. 80. 1. 3 26.1 4.9 5.9 283. 989. 74. 0. 2 26.4 5.7 6.5 252. 999. 71. 0. 1 25.8 3.5 6.7 219. 1005. 81. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2508311200 787935 **************************************************** PBO 2508311200 FORECAST PROJECTION=** LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.7 7.4 12.2 27. 104. 30. -0. 43 -76.0 7.8 6.7 45. 112. 28. -0. 42 -75.2 7.7 4.3 89. 120. 29. -0. 41 -72.8 8.5 6.0 112. 129. 27. -0. 40 -69.7 9.5 4.8 101. 139. 24. -0. 39 -66.9 9.5 5.7 43. 150. 25. 0. 38 -64.3 8.8 11.2 14. 161. 29. 1. 37 -61.3 8.8 14.8 5. 173. 30. 2. 36 -57.8 9.8 15.8 354. 186. 27. 3. 35 -54.1 11.8 15.3 339. 199. 22. 3. 34 -50.1 13.5 14.8 323. 214. 19. 3. 33 -46.3 15.0 13.7 319. 229. 17. 3. 32 -42.5 16.7 13.2 335. 244. 14. 3. 31 -39.0 15.4 14.2 358. 261. 18. 3. 30 -35.5 12.7 15.0 12. 279. 26. 3. 29 -32.1 10.2 14.8 22. 297. 36. 3. 28 -28.8 10.3 12.9 31. 316. 37. 3. 27 -25.4 12.4 9.7 39. 337. 30. 3. 26 -22.0 10.3 6.1 42. 358. 39. 2. 25 -19.0 5.4 5.3 92. 380. 62. 2. 24 -16.0 4.3 6.5 85. 404. 70. 1. 23 -13.4 6.5 8.8 56. 429. 58. 0. 22 -10.4 9.2 14.0 77. 454. 47. -0. 21 -7.6 6.1 19.0 91. 482. 62. -0. 20 -5.0 4.4 21.5 96. 510. 71. -0. 19 -2.4 4.1 21.3 99. 540. 73. -0. 18 0.2 4.1 20.2 102. 571. 74. 0. 17 3.0 4.6 18.5 104. 603. 72. 1. 16 5.7 5.1 16.1 102. 637. 70. 1. 15 8.1 4.6 15.4 101. 673. 73. 1. 14 10.3 4.0 15.1 96. 710. 76. 1. 13 12.2 2.1 13.9 85. 750. 87. -0. 12 13.7 0.6 12.2 77. 790. 96. -1. 11 15.6 2.2 12.7 68. 822. 87. -2. 10 17.1 2.6 12.0 58. 845. 85. -2. 9 18.4 2.4 10.3 45. 867. 86. -2. 8 19.8 3.0 8.2 31. 889. 83. -1. 7 21.3 3.6 6.3 4. 914. 80. -0. 6 22.9 3.7 6.1 334. 938. 80. 0. 5 24.2 4.0 6.4 318. 959. 78. 1. 4 25.3 4.2 6.7 306. 976. 77. 1. 3 26.2 4.6 7.6 293. 989. 76. 0. 2 26.6 6.2 9.6 278. 1000. 69. 0. 1 25.3 3.6 7.1 250. 1005. 80. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. **************************************************** STATION = 9.35N 82.25W PBO 2508311800 787935 **************************************************** PBO 2508311800 FORECAST PROJECTION=** LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -77.7 6.5 24.0 325. 104. 35. 0. 43 -78.4 5.9 19.8 297. 112. 38. 0. 42 -76.9 5.2 12.9 289. 120. 44. -0. 41 -74.6 4.7 3.6 337. 129. 48. -0. 40 -72.2 4.8 8.4 59. 139. 49. -1. 39 -69.2 4.7 13.6 60. 150. 50. -1. 38 -65.8 4.7 15.4 60. 161. 52. -2. 37 -62.0 4.6 16.0 53. 173. 54. -2. 36 -58.1 6.3 16.0 46. 186. 44. -2. 35 -54.1 10.1 14.6 40. 199. 28. -2. 34 -50.1 12.5 12.9 35. 213. 22. -2. 33 -46.0 15.1 12.1 32. 228. 16. -2. 32 -42.0 17.7 12.4 32. 244. 13. -1. 31 -38.1 17.5 13.2 32. 261. 14. -2. 30 -34.5 12.9 13.5 35. 278. 26. -2. 29 -31.1 10.7 12.8 48. 297. 34. -2. 28 -27.8 10.5 12.1 64. 316. 36. -2. 27 -24.5 14.0 9.2 74. 337. 26. -1. 26 -21.2 16.2 4.9 84. 358. 22. -1. 25 -18.1 16.5 3.3 65. 380. 22. 0. 24 -15.1 17.7 5.0 35. 404. 20. 1. 23 -12.3 17.3 7.5 40. 428. 22. 2. 22 -9.6 10.9 10.0 63. 454. 41. 2. 21 -6.8 7.5 14.1 81. 481. 55. 3. 20 -4.1 6.2 17.2 86. 510. 62. 2. 19 -1.6 5.2 19.1 88. 539. 67. 1. 18 0.6 4.3 21.4 89. 570. 73. -0. 17 3.0 4.3 22.2 87. 603. 74. -1. 16 5.6 4.8 22.1 85. 637. 71. -1. 15 8.3 5.4 21.8 87. 673. 69. -1. 14 10.8 5.9 19.4 90. 710. 67. -0. 13 13.0 5.3 14.6 83. 749. 70. -1. 12 14.9 4.2 11.2 62. 790. 76. -1. 11 16.3 3.0 8.8 56. 822. 82. -1. 10 17.3 2.6 5.7 62. 844. 85. -1. 9 18.4 2.0 2.7 66. 866. 88. -0. 8 19.6 1.3 1.4 326. 888. 92. 1. 7 21.3 1.8 3.7 329. 913. 89. 1. 6 23.1 2.6 6.8 345. 938. 85. 1. 5 24.8 3.7 9.0 350. 958. 80. 1. 4 26.2 4.8 10.1 352. 975. 75. 1. 3 27.3 5.6 10.7 354. 988. 71. 1. 2 28.1 6.3 11.2 356. 999. 69. 0. 1 28.1 4.7 9.5 4. 1005. 75. -0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1007. **************************************************** STATION = 9.35N 82.25W PBO 2509010000 787935 **************************************************** PBO 2509010000 FORECAST PROJECTION=** LYR TEMP DEPR KTS DIR PRES RH OMEG 44 -76.4 7.7 25.4 65. 104. 29. 0. 43 -76.6 8.0 12.5 45. 112. 27. 1. 42 -75.7 9.4 9.5 327. 120. 22. 1. 41 -73.5 11.6 15.0 297. 129. 16. 1. 40 -70.3 11.4 15.4 296. 139. 17. -0. 39 -67.2 11.0 7.7 313. 149. 20. -1. 38 -65.0 8.1 5.5 25. 161. 32. -1. 37 -62.0 5.5 7.3 36. 173. 48. -2. 36 -58.2 5.7 8.2 36. 186. 48. -2. 35 -54.2 7.8 8.7 35. 199. 38. -2. 34 -50.1 8.8 9.2 32. 213. 34. -2. 33 -46.2 7.8 9.6 30. 228. 41. -1. 32 -42.4 5.9 9.9 29. 244. 53. -1. 31 -38.9 4.0 10.4 34. 261. 66. -1. 30 -35.2 3.7 10.7 47. 278. 69. -1. 29 -31.6 4.9 10.5 57. 297. 62. -1. 28 -28.0 7.1 10.2 61. 316. 51. 0. 27 -24.5 9.1 10.1 61. 336. 43. 1. 26 -21.0 11.4 9.0 54. 358. 35. 2. 25 -17.9 12.3 9.3 41. 380. 33. 2. 24 -15.5 6.7 11.1 47. 404. 57. 2. 23 -12.9 4.5 13.1 66. 428. 69. 3. 22 -9.8 6.3 16.2 79. 454. 60. 4. 21 -7.1 5.6 18.8 80. 481. 64. 5. 20 -4.1 5.4 20.7 80. 510. 66. 5. 19 -1.6 3.3 24.2 82. 539. 78. 5. 18 1.1 3.0 27.3 86. 570. 81. 4. 17 3.4 1.9 27.5 84. 603. 87. 2. 16 5.8 2.1 25.0 76. 637. 86. 2. 15 8.2 3.1 19.6 72. 673. 81. 3. 14 10.0 2.4 14.5 68. 710. 85. 5. 13 11.2 0.0 12.8 57. 749. 100. 5. 12 14.4 0.0 13.4 63. 790. 100. 3. 11 16.6 0.1 9.9 83. 822. 100. 1. 10 17.1 0.1 4.3 99. 844. 100. 1. 9 17.8 0.1 1.1 171. 867. 100. 3. 8 19.2 0.1 1.6 256. 889. 100. 5. 7 20.5 0.1 1.8 289. 913. 100. 7. 6 21.4 0.1 1.9 338. 938. 100. 7. 5 22.5 0.5 3.5 24. 959. 97. 6. 4 23.7 1.2 5.7 32. 976. 93. 5. 3 24.5 1.7 7.4 29. 989. 90. 3. 2 25.0 1.2 7.4 19. 999. 93. 2. 1 25.5 1.5 6.9 19. 1005. 92. 0. PRCP(HR)=.000 PRCP(TOT)= 0.000 SFC PRES=1008. ****************************************************